1
-
-
0024087698
-
Natural contamination test of insulators with DC voltage energization at Inland areas
-
K. Takasu, T. Shindo, and N. Arai Natural contamination test of insulators with DC voltage energization at Inland areas IEEE Transactions on Power Delivery 3 October (4) 1988 1847 1853
-
(1988)
IEEE Transactions on Power Delivery
, vol.3
, Issue.OCTOBER 4
, pp. 1847-1853
-
-
Takasu, K.1
Shindo, T.2
Arai, N.3
-
2
-
-
0025898317
-
Performance of HV transmission line insulator on desert conditions. Part 3: Pollution measurement at a coastal site in the eastern region of Saudi Arabia
-
M. Akbar, and F. Zedan Performance of HV transmission line insulator on desert conditions. Part 3: pollution measurement at a coastal site in the eastern region of Saudi Arabia IEEE Transactions on Power Delivery 6 January (1) 1991 429 438
-
(1991)
IEEE Transactions on Power Delivery
, vol.6
, Issue.JANUARY 1
, pp. 429-438
-
-
Akbar, M.1
Zedan, F.2
-
4
-
-
84880875427
-
Important requirement on insulators under polluted conditions
-
Hermsdorf Germany
-
H. Streubel, Important requirement on insulators under polluted conditions, Journal of technical informations, Hermsdorf, n 20, 881-892, Germany, 1970.
-
(1970)
Journal of Technical Informations
, Issue.20
, pp. 881-892
-
-
Streubel, H.1
-
7
-
-
22744453285
-
Effect of non-uniform contaminating layers on insulators on breakdown voltage
-
J.G. Wankowicz, and L. Berndt Effect of non-uniform contaminating layers on insulators on breakdown voltage Elektrie 46 11 1992 460 464
-
(1992)
Elektrie
, vol.46
, Issue.11
, pp. 460-464
-
-
Wankowicz, J.G.1
Berndt, L.2
-
8
-
-
0027579052
-
Dynamic arc modelling of pollution flashover of insulators under DC voltage
-
R. Sundararajan, and R.S. Gorur Dynamic arc modelling of pollution flashover of insulators under DC voltage IEEE Transactions on Electrical Insulation 28 2 1993 209 218
-
(1993)
IEEE Transactions on Electrical Insulation
, vol.28
, Issue.2
, pp. 209-218
-
-
Sundararajan, R.1
Gorur, R.S.2
-
9
-
-
84880911760
-
Performance of outdoor insulators under non-uniform conditions
-
Beijing, Chine
-
R. Boudissa, A. Haddad, Z. Sahli, A. Mekhaldi, and R. Bärsch Performance of outdoor insulators under non-uniform conditions 14th ISH Tsinghua University, août Beijing, Chine 2005
-
(2005)
14th ISH Tsinghua University, Août
-
-
Boudissa, R.1
Haddad, A.2
Sahli, Z.3
Mekhaldi, A.4
Bärsch, R.5
-
10
-
-
22744454070
-
Effect of insulator shape on surface discharges and flashover under polluted conditions
-
DOI 10.1109/TDEI.2005.1453447
-
R. Boudissa, S. Djafri, A. Haddad, R. Belaicha, and R. Bärsch Effect of insulator shape on surface discharges and flashover under polluted conditions IEEE Transactions on Dielectrics and Electrical Insulation 12 June (3) 2005 429 437 (Pubitemid 41028263)
-
(2005)
IEEE Transactions on Dielectrics and Electrical Insulation
, vol.12
, Issue.3
, pp. 429-437
-
-
Boudissa, R.1
Djafri, S.2
Haddad, A.3
Belaicha, R.4
Bearsch, R.5
-
12
-
-
84880854961
-
Investigation about flashover performance of insulators under uniform and non-uniform contamination
-
Dresden, Germany
-
M.N. Rayes, and M. Zhirh Investigation about flashover performance of insulators under uniform and non-uniform contamination 7th International Symposium on HV Engineering, Rapport 43 - 08 Dresden, Germany 1991
-
(1991)
7th International Symposium on HV Engineering, Rapport 43 - 08
-
-
Rayes, M.N.1
Zhirh, M.2
-
14
-
-
79551687265
-
Prediction parameters of dimensioning of insulators under non-uniform contaminated conditions by multiple regression analysis
-
Z. Sahli, A. Mekhaldi, R. Boudissa, and S. Boudrahem Prediction parameters of dimensioning of insulators under non-uniform contaminated conditions by multiple regression analysis Electric Power Systems Research 81 Avril (4) 2011 821 829
-
(2011)
Electric Power Systems Research
, vol.81
, Issue.AVRIL 4
, pp. 821-829
-
-
Sahli, Z.1
Mekhaldi, A.2
Boudissa, R.3
Boudrahem, S.4
-
16
-
-
84880905950
-
Influence of insulator diameter on contamination flashover voltage
-
K. Naito, R. Matsuoka, S. Ito, K. Sakanishi, and O. Fujii Influence of insulator diameter on contamination flashover voltage IEEE Mexico Section Meeting Paper RVP-9-INS-02, July 1989
-
(1989)
IEEE Mexico Section Meeting Paper RVP-9-INS-02, July
-
-
Naito, K.1
Matsuoka, R.2
Ito, S.3
Sakanishi, K.4
Fujii, O.5
-
17
-
-
0026239160
-
Modelling of HVDC wall bushing flashover in non-uniform rain
-
F.A.M. Rizk, and S.I. Kamel Modelling of HVDC wall bushing flashover in non-uniform rain IEEE Transactions on Power Delivery 6 4 1991 1650 1662
-
(1991)
IEEE Transactions on Power Delivery
, vol.6
, Issue.4
, pp. 1650-1662
-
-
Rizk, F.A.M.1
Kamel, S.I.2
|