메뉴 건너뛰기




Volumn , Issue , 2012, Pages 1651-1654

Signal transmission through human muscle for implantable medical devices using galvanic intra-body communication technique

Author keywords

[No Author keywords available]

Indexed keywords

BODY TISSUES; ELECTROMAGNETIC MODELS; HUMAN MUSCLES; HUMAN TISSUES; IMPLANTABLE MEDICAL DEVICES; INTRA-BODY COMMUNICATIONS; MONITORING FUNCTIONS; PATH LOSS; POTENTIAL INTERFERENCES; RADIO FREQUENCY TRANSMISSION; RESEARCH DIRECTIONS; RESEARCH TOPICS; RF DATA; SENSOR DEVICE; SIGNAL TRANSMISSION; TRANSMITTING SIGNAL;

EID: 84880837305     PISSN: 1557170X     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EMBC.2012.6346263     Document Type: Conference Paper
Times cited : (11)

References (23)
  • 1
    • 83455179364 scopus 로고    scopus 로고
    • Medical sensors encompass biomedical electronics
    • Dec.
    • S. Taranovich, "Medical sensors encompass biomedical electronics," EDN, pp. 280-287, Dec. 2011.
    • (2011) EDN , pp. 280-287
    • Taranovich, S.1
  • 2
    • 57149090487 scopus 로고    scopus 로고
    • Deep brain stimulation of the subthalamic nucleus for the treatment of parkinson's disease
    • A. L. Benabid, S. Chabardes, J. Mitrofanis, and P. Pollak, "Deep brain stimulation of the subthalamic nucleus for the treatment of parkinson's disease," Lancet Neurol., vol. 8(1), pp. 67-81, 2009.
    • (2009) Lancet Neurol. , vol.8 , Issue.1 , pp. 67-81
    • Benabid, A.L.1    Chabardes, S.2    Mitrofanis, J.3    Pollak, P.4
  • 3
    • 77749323179 scopus 로고    scopus 로고
    • Deaths and cardiovascular injuries due to deviceassisted implantable cardioverter-defibrillator and pacemaker lead extraction
    • R. G. Hauser, W. T. Katsiyiannis, C. C. Gornick, A. K. Almquist, and L. M. Kallinen, "Deaths and cardiovascular injuries due to deviceassisted implantable cardioverter-defibrillator and pacemaker lead extraction," Europace, vol. 12(3), pp. 395-401, 2010.
    • (2010) Europace , vol.12 , Issue.3 , pp. 395-401
    • Hauser, R.G.1    Katsiyiannis, W.T.2    Gornick, C.C.3    Almquist, A.K.4    Kallinen, L.M.5
  • 6
    • 79960099894 scopus 로고    scopus 로고
    • Wireless communication with implanted medical devices using the conductive properties of the body
    • J. E. Ferguson and A. D. Redish, "Wireless communication with implanted medical devices using the conductive properties of the body," Expert Rev Med Devices, vol. 8, no. 4, pp. 427-33, 2011.
    • (2011) Expert Rev Med Devices , vol.8 , Issue.4 , pp. 427-433
    • Ferguson, J.E.1    Redish, A.D.2
  • 7
    • 79960099894 scopus 로고    scopus 로고
    • Non-U.S. Gov't review England expert review of medical devices
    • T32-EB008389/EB/NIBIB NIH HHS/United States Research Support, N.I.H., Extramural Research Support Jul
    • Ferguson, John E Redish, A David T32-EB008389/EB/NIBIB NIH HHS/United States Research Support, N.I.H., Extramural Research Support, Non-U.S. Gov't Review England Expert review of medical devices Expert Rev Med Devices. 2011 Jul;8(4):427-33.
    • (2011) Expert Rev Med Devices , vol.8 , Issue.4 , pp. 427-433
    • Ferguson, J.E.R.1    David, A.2
  • 8
    • 76249111797 scopus 로고    scopus 로고
    • Inductive link design for medical implants
    • ISIEA 2009. IEEE Symposium on
    • H. Ali, T. J. Ahmad, and S. A. Khan, "Inductive link design for medical implants," in Industrial Electronics & Applications, 2009. ISIEA 2009. IEEE Symposium on, vol. 2, pp. 694-699.
    • Industrial Electronics & Applications, 2009 , vol.2 , pp. 694-699
    • Ali, H.1    Ahmad, T.J.2    Khan, S.A.3
  • 10
    • 10944259963 scopus 로고    scopus 로고
    • A wideband frequency-shift keying wireless link for inductively powered biomedical implants
    • IEEE Transactions on
    • M. Ghovanloo and K. Najafi, "A wideband frequency-shift keying wireless link for inductively powered biomedical implants," Circuits and Systems I: Regular Papers, IEEE Transactions on, vol. 51, no. 12, pp. 2374-2383, 2004.
    • (2004) Circuits and Systems I: Regular Papers , vol.51 , Issue.12 , pp. 2374-2383
    • Ghovanloo, M.1    Najafi, K.2
  • 11
    • 79951935613 scopus 로고    scopus 로고
    • Optimal frequencies for inductive powering of fully implantable biosensors for chronic and elderly patients
    • IEEE
    • J. Olivo, S. Carrara, and G. De Micheli, "Optimal frequencies for inductive powering of fully implantable biosensors for chronic and elderly patients," in Sensors, 2010 IEEE, pp. 99-103.
    • (2010) Sensors , pp. 99-103
    • Olivo, J.1    Carrara, S.2    De Micheli, G.3
  • 12
    • 79961134633 scopus 로고    scopus 로고
    • Energy harvesting and remote powering for implantable biosensors
    • J. Olivo, S. Carrara, and G. De Micheli, "Energy harvesting and remote powering for implantable biosensors," Sensors Journal, IEEE, vol. 11, no. 7, pp. 1573-1586, 2011.
    • (2011) Sensors Journal, IEEE , vol.11 , Issue.7 , pp. 1573-1586
    • Olivo, J.1    Carrara, S.2    De Micheli, G.3
  • 13
    • 57649203380 scopus 로고    scopus 로고
    • Optimal operating frequency in wireless power transmission for implantable devices
    • EMBS 2007. 29th Annual International Conference of the IEEE
    • A. S. Y. Poon, S. O'Driscoll, and T. H. Meng, "Optimal operating frequency in wireless power transmission for implantable devices," in Engineering in Medicine and Biology Society, 2007. EMBS 2007. 29th Annual International Conference of the IEEE, pp. 5673-5678.
    • Engineering in Medicine and Biology Society, 2007 , pp. 5673-5678
    • Poon, A.S.Y.1    O'Driscoll, S.2    Meng, T.H.3
  • 14
    • 27544452115 scopus 로고    scopus 로고
    • Mics transceivers: Regulatory standards and applications [medical implant communications service]
    • Proceedings. IEEE
    • H. S. Savci, A. Sula, Z. Wang, N. S. Dogan, and E. Arvas, "Mics transceivers: regulatory standards and applications [medical implant communications service]," in SoutheastCon, 2005. Proceedings. IEEE, pp. 179-182.
    • SoutheastCon, 2005 , pp. 179-182
    • Savci, H.S.1    Sula, A.2    Wang, Z.3    Dogan, N.S.4    Arvas, E.5
  • 15
    • 77950964819 scopus 로고    scopus 로고
    • Ibcom (intra-brain communication) microsystem: Wireless transmission of neural signals within the brain
    • EMBC 2009. Annual International Conference of the IEEE
    • K. M. Al-Ashmouny, C. Boldt, J. E. Ferguson, A. G. Erdman, A. D. Redish, and Y. Euisik, "Ibcom (intra-brain communication) microsystem: Wireless transmission of neural signals within the brain," in Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE, pp. 2054-2057.
    • Engineering in Medicine and Biology Society, 2009 , pp. 2054-2057
    • Al-Ashmouny, K.M.1    Boldt, C.2    Ferguson, J.E.3    Erdman, A.G.4    Redish, A.D.5    Euisik, Y.6
  • 17
    • 63449136937 scopus 로고    scopus 로고
    • A 350uw cmos msk transmitter and 400uw ook super-regenerative receiver for medical implant communications
    • IEEE Journal of
    • J. L. Bohorquez, A. P. Chandrakasan, and J. L. Dawson, "A 350uw cmos msk transmitter and 400uw ook super-regenerative receiver for medical implant communications," Solid-State Circuits, IEEE Journal of, vol. 44, no. 4, pp. 1248-1259, 2009.
    • (2009) Solid-State Circuits , vol.44 , Issue.4 , pp. 1248-1259
    • Bohorquez, J.L.1    Chandrakasan, A.P.2    Dawson, J.L.3
  • 18
    • 4344669264 scopus 로고    scopus 로고
    • Physical limitations of antennas in a lossy medium
    • IEEE Transactions on
    • A. Karlsson, "Physical limitations of antennas in a lossy medium," Antennas and Propagation, IEEE Transactions on, vol. 52, no. 8, pp. 2027-2033, 2004.
    • (2004) Antennas and Propagation , vol.52 , Issue.8 , pp. 2027-2033
    • Karlsson, A.1
  • 19
    • 84947899682 scopus 로고    scopus 로고
    • Modeling for intra-body communication with bone effect
    • EMBC 2009. Annual International Conference of the IEEE
    • S. H. Pun, Y. M. Gao, P. U. Mak, M. Du, and M. I. Vai, "Modeling for intra-body communication with bone effect," in Engineering in Medicine and Biology Society, 2009. EMBC 2009. Annual International Conference of the IEEE, pp. 693-696.
    • Engineering in Medicine and Biology Society, 2009 , pp. 693-696
    • Pun, S.H.1    Gao, Y.M.2    Mak, P.U.3    Du, M.4    Vai, M.I.5
  • 20
    • 0029957193 scopus 로고    scopus 로고
    • The dielectric properties of biological tissues: III. parametric models for the dielectric spectrum of tissues
    • S. Gabriel, R. W. Lau, and C. Gabriel, "The dielectric properties of biological tissues: Iii. parametric models for the dielectric spectrum of tissues," Physics in Medicine and Biology, vol. 41, pp. 2271-2293, 1996.
    • (1996) Physics in Medicine and Biology , vol.41 , pp. 2271-2293
    • Gabriel, S.1    Lau, R.W.2    Gabriel, C.3
  • 21
    • 84870850912 scopus 로고    scopus 로고
    • last accessed on Mar. 1, 2012
    • "Cosmol multiphysics available in http://www.comsol.com/," last accessed on Mar. 1, 2012.
  • 22
    • 65349089624 scopus 로고    scopus 로고
    • Path loss model for in-body communication in homogeneous human muscle tissue
    • D. Kurup, W. Joseph, G. Vermeeren, and L. Martens, "Path loss model for in-body communication in homogeneous human muscle tissue," Electronics Letters, vol. 45, no. 9, pp. 453-454, 2009.
    • (2009) Electronics Letters , vol.45 , Issue.9 , pp. 453-454
    • Kurup, D.1    Joseph, W.2    Vermeeren, G.3    Martens, L.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.