메뉴 건너뛰기




Volumn 82, Issue 2, 2013, Pages

Transcatheter aortic valve implantation for severe, non-calcified aortic regurgitation and narrow aortic root: Description from a case report of a new approach to potentially avoid coronary artery obstruction

Author keywords

aortic regurgitation; transcatheter aortic valve implantation

Indexed keywords

AGED; AORTA ROOT; AORTA SINUS; AORTA VALVE REGURGITATION; AORTA VALVE REPLACEMENT; ARTICLE; CASE REPORT; CORONARY ARTERY OBSTRUCTION; DISEASE SEVERITY; FEMALE; HEART VALVE PROSTHESIS; HIGH RISK PATIENT; HUMAN; OUTCOME ASSESSMENT; SURGICAL APPROACH; SURGICAL RISK; TRANSCATHETER AORTIC VALVE IMPLANTATION;

EID: 84880620434     PISSN: 15221946     EISSN: 1522726X     Source Type: Journal    
DOI: 10.1002/ccd.24541     Document Type: Article
Times cited : (12)

References (3)
  • 1
    • 77956879404 scopus 로고    scopus 로고
    • Compassionate aortic valve implantation for severe aortic regurgitation
    • Ducrocq G, Himbert D, Hvass U, Vahanian A,. Compassionate aortic valve implantation for severe aortic regurgitation. J Thorac Cardiovasc Surg 2010; 140: 930-932.
    • (2010) J Thorac Cardiovasc Surg , vol.140 , pp. 930-932
    • Ducrocq, G.1    Himbert, D.2    Hvass, U.3    Vahanian, A.4
  • 2
    • 84856490731 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation for severe aortic regurgitation in a stentless bioprosthetic valve with the CoreValve revalving system - Technical tips and role of the Accutrak system
    • Sarkar K, Ussia GP, Tamburino C,. Transcatheter aortic valve implantation for severe aortic regurgitation in a stentless bioprosthetic valve with the CoreValve revalving system-Technical tips and role of the Accutrak system. Catheter Cardiovasc Interv 2011; 78: 485-490.
    • (2011) Catheter Cardiovasc Interv , vol.78 , pp. 485-490
    • Sarkar, K.1    Ussia, G.P.2    Tamburino, C.3
  • 3
    • 55849132881 scopus 로고    scopus 로고
    • Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval
    • Piazza N, Grube E, Gerckens U, den Heijer P, Linke A, Luha O, Ramondo A, Ussia G, Wenaweser P, Windecker S, Laborde JC, de Jaegere P, Serruys PW,. Procedural and 30-day outcomes following transcatheter aortic valve implantation using the third generation (18 Fr) corevalve revalving system: Results from the multicentre, expanded evaluation registry 1-year following CE mark approval. EuroIntervention 2008; 4: 242-249.
    • (2008) EuroIntervention , vol.4 , pp. 242-249
    • Piazza, N.1    Grube, E.2    Gerckens, U.3    Den Heijer, P.4    Linke, A.5    Luha, O.6    Ramondo, A.7    Ussia, G.8    Wenaweser, P.9    Windecker, S.10    Laborde, J.C.11    De Jaegere, P.12    Serruys, P.W.13