메뉴 건너뛰기




Volumn 117, Issue 1, 2013, Pages 83-90

An assessment of global end-diastolic volume and extravascular lung water index during one-lung ventilation: Is transpulmonary thermodilution usable?

Author keywords

[No Author keywords available]

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL MODEL; ARTICLE; CONTROLLED STUDY; EXTRAVASCULAR LUNG WATER INDEX; FEMALE; GLOBAL END DIASTOLIC VOLUME INDEX; HEART OUTPUT MEASUREMENT; HYPOVOLEMIA; NONHUMAN; ONE LUNG VENTILATION; PRIORITY JOURNAL; PULMONARY ARTERY; RATING SCALE; SWINE; THERMODILUTION; THERMODILUTION DEVICE;

EID: 84880571062     PISSN: 00032999     EISSN: 15267598     Source Type: Journal    
DOI: 10.1213/ANE.0b013e31828f2c39     Document Type: Article
Times cited : (10)

References (22)
  • 1
    • 77949305811 scopus 로고    scopus 로고
    • Cardiac output monitoring using indicator-dilution techniques: Basics, limits, and perspectives
    • Reuter DA, Huang C, Edrich T, Shernan SK, Eltzschig HK. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg 2010;110:799-811
    • (2010) Anesth Analg , vol.110 , pp. 799-811
    • Reuter, D.A.1    Huang, C.2    Edrich, T.3    Shernan, S.K.4    Eltzschig, H.K.5
  • 3
    • 33846323221 scopus 로고    scopus 로고
    • Goal-directed fuid management reduces vasopressor and catecholamine use in cardiac surgery patients
    • Goepfert MS, Reuter DA, Akyol D, Lamm P, Kilger E, Goetz AE. Goal-directed fuid management reduces vasopressor and catecholamine use in cardiac surgery patients. Intensive Care Med 2007;33:96-103
    • (2007) Intensive Care Med , vol.33 , pp. 96-103
    • Goepfert, M.S.1    Reuter, D.A.2    Akyol, D.3    Lamm, P.4    Kilger, E.5    Goetz, A.E.6
  • 4
    • 77952511173 scopus 로고    scopus 로고
    • Transpulmonary thermodilution using femoral indicator injection: A prospective trial in patients with a femoral and a jugular central venous catheter
    • Saugel B, Umgelter A, Schuster T, Phillip V, Schmid RM, Huber W. Transpulmonary thermodilution using femoral indicator injection: a prospective trial in patients with a femoral and a jugular central venous catheter. Crit Care 2010;14:R95
    • (2010) Crit Care , vol.14
    • Saugel, B.1    Umgelter, A.2    Schuster, T.3    Phillip, V.4    Schmid, R.M.5    Huber, W.6
  • 6
    • 43049162424 scopus 로고    scopus 로고
    • Evidence-based management of one-lung ventilation
    • Lohser J. Evidence-based management of one-lung ventilation. Anesthesiol Clin 2008;26:241-72
    • (2008) Anesthesiol Clin , vol.26 , pp. 241-272
    • Lohser, J.1
  • 7
    • 34247166300 scopus 로고    scopus 로고
    • Bedside assessment of extravascular lung water by dilution methods: Temptations and pitfalls
    • Michard F. Bedside assessment of extravascular lung water by dilution methods: temptations and pitfalls. Crit Care Med 2007;35:1186-92
    • (2007) Crit Care Med , vol.35 , pp. 1186-1192
    • Michard, F.1
  • 10
    • 0021978646 scopus 로고
    • Hypoxic pulmonary vasoconstriction in the human lung: Effect of repeated hypoxic challenges during anesthesia
    • Bindslev L, Jolin A, Hedenstierna G, Baehrendtz S, Santesson J. Hypoxic pulmonary vasoconstriction in the human lung: effect of repeated hypoxic challenges during anesthesia. Anesthesiology 1985;62:621-5
    • (1985) Anesthesiology , vol.62 , pp. 621-625
    • Bindslev, L.1    Jolin, A.2    Hedenstierna, G.3    Baehrendtz, S.4    Santesson, J.5
  • 11
    • 84856163851 scopus 로고    scopus 로고
    • Beyond effect size: Consideration of the minimum effect size of interest in anesthesia trials
    • Gibbs NM, Weightman WM. Beyond effect size: consideration of the minimum effect size of interest in anesthesia trials. Anesth Analg 2012;114:471-5
    • (2012) Anesth Analg , vol.114 , pp. 471-475
    • Gibbs, N.M.1    Weightman, W.M.2
  • 12
    • 68849121782 scopus 로고    scopus 로고
    • Bench-to-bedside review: The importance of the precision of the reference technique in method comparison studies-with spe-cifc reference to the measurement of cardiac output
    • Cecconi M, Rhodes A, Poloniecki J, Della Rocca G, Grounds RM. Bench-to-bedside review: the importance of the precision of the reference technique in method comparison studies-with spe-cifc reference to the measurement of cardiac output. Crit Care 2009;13:201
    • (2009) Crit Care , vol.13 , pp. 201
    • Cecconi, M.1    Rhodes, A.2    Poloniecki, J.3    Della Rocca, G.4    Grounds, R.M.5
  • 13
    • 0021220390 scopus 로고
    • Cardiopulmonary monitoring of critically ill patients (2)
    • Goldenheim PD, Kazemi H. Cardiopulmonary monitoring of critically ill patients (2). N Engl J Med 1984;311:776-80
    • (1984) N Engl J Med , vol.311 , pp. 776-780
    • Goldenheim, P.D.1    Kazemi, H.2
  • 14
    • 0023029836 scopus 로고
    • Limitations of cardiac output measurements by thermodilution
    • Nadeau S, Noble WH. Limitations of cardiac output measurements by thermodilution. Can Anaesth Soc J 1986;33:780-4
    • (1986) Can Anaesth Soc J , vol.33 , pp. 780-784
    • Nadeau, S.1    Noble, W.H.2
  • 16
    • 0020435965 scopus 로고
    • Effect of atelectasis and embolization on extravascular thermal volume of the lung
    • Beckett RC, Gray BA. Effect of atelectasis and embolization on extravascular thermal volume of the lung. J Appl Physiol 1982;53:1614-9
    • (1982) J Appl Physiol , vol.53 , pp. 1614-1619
    • Beckett, R.C.1    Gray, B.A.2
  • 17
    • 0018774477 scopus 로고
    • Thermal-dye lung water measurements: Effects of edema and embolization
    • Oppenheimer L, Elings VB, Lewis FR. Thermal-dye lung water measurements: effects of edema and embolization. J Surg Res 1979;26:504-12
    • (1979) J Surg Res , vol.26 , pp. 504-512
    • Oppenheimer, L.1    Elings, V.B.2    Lewis, F.R.3
  • 19
    • 0022370735 scopus 로고
    • Lung water measurements with the mean transit time approach
    • Effros RM. Lung water measurements with the mean transit time approach. J Appl Physiol 1985;59:673-83
    • (1985) J Appl Physiol , vol.59 , pp. 673-683
    • Effros, R.M.1
  • 21
    • 15844382038 scopus 로고    scopus 로고
    • Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep
    • Kirov MY, Kuzkov VV, Kuklin VN, Waerhaug K, Bjertnaes LJ. Extravascular lung water assessed by transpulmonary single thermodilution and postmortem gravimetry in sheep. Crit Care 2004;8:R451-8
    • (2004) Crit Care , vol.8
    • Kirov, M.Y.1    Kuzkov, V.V.2    Kuklin, V.N.3    Waerhaug, K.4    Bjertnaes, L.J.5
  • 22
    • 33646582606 scopus 로고    scopus 로고
    • Comparison of a single indicator and gravimetric technique for estimation of extravascular lung water in endotoxemic pigs
    • Rossi P, Wanecek M, Rudehill A, Konrad D, Weitzberg E, Oldner A. Comparison of a single indicator and gravimetric technique for estimation of extravascular lung water in endotoxemic pigs. Crit Care Med 2006;34:1437-43
    • (2006) Crit Care Med , vol.34 , pp. 1437-1443
    • Rossi, P.1    Wanecek, M.2    Rudehill, A.3    Konrad, D.4    Weitzberg, E.5    Oldner, A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.