Volumn 60, Issue 7, 2013, Pages 1386-1400

Techniques and evaluation from a cross-platform imaging comparison of quantitative ultrasound parameters in an in vivo rodent fibroadenoma model

Author keywords

[No Author keywords available]

Indexed keywords

BACKSCATTER COEFFICIENTS; FREQUENCY-DEPENDENT ATTENUATION; POWER-LAW DEPENDENCES; QUANTITATIVE ULTRASOUNDS; SIGNIFICANT DIFFERENCES; STATISTICAL COMPARISONS; STATISTICALLY SIGNIFICANT DIFFERENCE; ULTRASOUND IMAGING SYSTEMS;

EID: 84880437499     PISSN: 08853010     EISSN: None     Source Type: Journal    
DOI: 10.1109/TUFFC.2013.2711     Document Type: Article
Times cited : (17)

References (29)
  • 2
    • 0022633907 scopus 로고
    • Diagnostic spectrum analysis in ophthalmology: A physical perspective
    • DOI 10.1016/0301-5629(86)90183-3
    • E. J. Feleppa, F. L. Lizzi, D. J. Coleman, and M. M. Yaremko, "Diagnostic spectrum analysis in ophthalmology: A physical perspective," Ultrasound Med. Biol., vol. 12, no. 8, pp. 623-631, 1986. (Pubitemid 16095156)
    • (1986) Ultrasound in Medicine and Biology , vol.12 , Issue.8 , pp. 623-631
    • Feleppa, E.J.1    Lizzi, F.L.2    Coleman, D.J.3    Yaremko, M.M.4
  • 5
    • 0028804921 scopus 로고
    • Effects of endothelin-1 on renal microvasculature measured using quantitative ultrasound
    • M. F. Insana, J. G. Wood, T. J. Hall, G. G. Cox, and L. A. Harrison, "Effects of endothelin-1 on renal microvasculature measured using quantitative ultrasound," Ultrasound Med. Biol., vol. 21, no. 9, pp. 1143-1151, 1995.
    • (1995) Ultrasound Med. Biol , vol.21 , Issue.9 , pp. 1143-1151
    • Insana, M.F.1    Wood, J.G.2    Hall, T.J.3    Cox, G.G.4    Harrison, L.A.5
  • 6
    • 0030448232 scopus 로고    scopus 로고
    • Ultrasonic measurement of glomerular diameters in normal adult humans
    • DOI 10.1016/S0301-5629(96)00142-1
    • T. J. Hall, M. F. Insana, L. A. Harrison, and G. G. Cox, "Ultrasonic measurement of glomerular diameters in normal adult humans," Ultrasound Med. Biol., vol. 22, no. 8, pp. 987-997, 1996. (Pubitemid 26423853)
    • (1996) Ultrasound in Medicine and Biology , vol.22 , Issue.8 , pp. 987-997
    • Hall, T.J.1    Insana, M.F.2    Harrison, L.A.3    Cox, G.G.4
  • 7
    • 0024501867 scopus 로고
    • Quantitative ultrasonic detection and classification of diffuse liver disease comparison with human observer performance
    • DOI 10.1097/00004424-198903000-00004
    • B. Garra, M. Insana, T. Shawker, R. F. Wagner, M. Bradford, and M. Russell, "Quantitative ultrasonic detection and classification of diffuse liver disease. Comparison with human observer performance," Invest. Radiol., vol. 24, no. 3, pp. 196-203, 1989. (Pubitemid 19084784)
    • (1989) Investigative Radiology , vol.24 , Issue.3 , pp. 196-203
    • Garra, B.S.1    Insana, M.F.2    Shawker, T.H.3    Wagner, R.F.4    Bradford, M.5    Russell, M.6
  • 13
    • 12344320182 scopus 로고    scopus 로고
    • An F test for linear models with functional responses
    • Q. Shen and J. Faraway, "An F test for linear models with functional responses," Statist. Sinica, vol. 14, no. 4, pp. 1239-1257, 2004. (Pubitemid 40131612)
    • (2004) Statistica Sinica , vol.14 , Issue.4 , pp. 1239-1257
    • Shen, Q.1    Faraway, J.2
  • 14
    • 0025230571 scopus 로고
    • Backscatter coefficient measurements using a reference phantom to extract depth-dependent instrumentation factors
    • DOI 10.1016/0161-7346(90)90221-I
    • L. X. Yao, J. A. Zagzebski, and E. L. Madsen, "Backscatter coefficient measurements using a reference phantom to extract depthdependent instrumentation factors," Ultrason. Imaging, vol. 12, no. 1, pp. 58-70, 1990. (Pubitemid 20156728)
    • (1990) Ultrasonic Imaging , vol.12 , Issue.1 , pp. 58-70
    • Yao, L.X.1    Zagzebski, J.A.2    Madsen, E.L.3
  • 15
    • 32044445549 scopus 로고    scopus 로고
    • Stability of heterogeneous elastography phantoms made from oil dispersions in aqueous gels
    • DOI 10.1016/j.ultrasmedbio.2005.10.009, PII S0301562905004199
    • E. L. Madsen, M. A. Hobson, H. Shi, T. Varghese, and G. R. Frank, "Stability of heterogeneous elastography phantoms made from oil dispersions in aqueous gels," Ultrasound Med. Biol., vol. 32, no. 2, pp. 261-270, 2006. (Pubitemid 43197849)
    • (2006) Ultrasound in Medicine and Biology , vol.32 , Issue.2 , pp. 261-270
    • Madsen, E.L.1    Hobson, M.A.2    Shi, H.3    Varghese, T.4    Frank, G.R.5
  • 18
    • 79959587248 scopus 로고    scopus 로고
    • On the estimation of backscatter coefficients using single-element focused transducers
    • R . Lavarello, G. Ghoshal, and M. L. Oelze, "On the estimation of backscatter coefficients using single-element focused transducers," J. Acoust. Soc. Am., vol. 129, no. 5, pp. 2903-2911, 2011.
    • (2011) J. Acoust. Soc. Am. , vol.129 , Issue.5 , pp. 2903-2911
    • Lavarello, R.1    Ghoshal, G.2    Oelze, M.L.3
  • 20
    • 0028362545 scopus 로고
    • Acoustic coupling from a focused transducer to a flat plate and back to the transducer
    • DOI 10.1121/1.409996
    • X. Chen, K. Q. Schwarz, and K. J. Parker, "Acoustic coupling from a focused transducer to a flat plate and back to the transducer," J. Acoust. Soc. Am., vol. 95, no. 6, pp. 3049-3054, Jun. 1994. (Pubitemid 24189457)
    • (1994) Journal of the Acoustical Society of America , vol.95 , Issue.6 , pp. 3049-3054
    • Chen, X.1    Schwarz, K.Q.2    Parker, K.J.3
  • 21
    • 4544317990 scopus 로고    scopus 로고
    • An ANOVA test for functional data
    • A . Cuevas, M. Febrero, and R. Fraiman, "An ANOVA test for functional data," Comput. Stat. Data Anal., vol. 47, no. 1, pp. 111-122, 2004.
    • (2004) Comput. Stat. Data Anal , vol.47 , Issue.1 , pp. 111-122
    • Cuevas, A.1    Febrero, M.2    Fraiman, R.3
  • 25
    • 0038661387 scopus 로고    scopus 로고
    • Statistics of ultrasonic scatterer size estimation with a reference phantom
    • DOI 10.1121/1.1568945
    • A . Gerig, J. Zagzebski, and T. Varghese, "Statistics of ultrasound scatterer size estimation with a reference phantom," J. Acoust. Soc. Am., vol. 113, no. 6, pp. 3430-3437, Jun. 2003. (Pubitemid 36676534)
    • (2003) Journal of the Acoustical Society of America , vol.113 , Issue.6 , pp. 3430-3437
    • Gerig, A.1    Zagzebski, J.2    Varghese, T.3
  • 26
    • 0036714292 scopus 로고    scopus 로고
    • Characterization of tissue microstructure using ultrasonic backscatter: Theory and technique for optimization using a Gaussian form factor
    • DOI 10.1121/1.1501278
    • M. L. Oelze, J. F. Zachary, and W. D. O'Brien Jr., "Characterization of tissue microstructure using ultrasonic backscatter: Theory and technique for optimization using a Gaussian form factor," J. Acoust. Soc. Am., vol. 112, no. 3, pt. 1, pp. 1202-1211, 2002. (Pubitemid 35006673)
    • (2002) Journal of the Acoustical Society of America , vol.112 , Issue.3 , pp. 1202-1211
    • Oelze, M.L.1    Zachary, J.F.2    O'Brien Jr., W.D.3
  • 27
    • 2942609260 scopus 로고    scopus 로고
    • Differentiation and characterization of rat mammary fibroadenomas and 4T1 mouse Carcinomas using quantitative ultrasound imaging
    • M. L. Oelze, W. D. O'Brien Jr., J. P. Blue, and J. F. Zachary, "Differentiation and characterization of rat mammary fibroadenomas and 4T1 mouse Carcinomas using quantitative ultrasound imaging," IEEE Trans. Med. Imaging, vol. 23, no. 6, pp. 764-771, 2004.
    • (2004) IEEE Trans. Med. Imaging , vol.23 , Issue.6 , pp. 764-771
    • Oelze, M.L.1    O'Brien Jr., W.D.2    Blue, J.P.3    Zachary, J.F.4
  • 28
    • 33750724543 scopus 로고    scopus 로고
    • Examination of cancer in mouse models using high-frequency quantitative ultrasound
    • DOI 10.1016/j.ultrasmedbio.2006.05.006, PII S0301562906016061
    • M. L. Oelze and J. F. Zachary, "Examination of cancer in mouse models using high-frequency quantitative ultrasound," Ultrasound Med. Biol., vol. 32, no. 11, pp. 1639-1648, 2006. (Pubitemid 44716576)
    • (2006) Ultrasound in Medicine and Biology , vol.32 , Issue.11 , pp. 1639-1648
    • Oelze, M.L.1    Zachary, J.F.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.