-
2
-
-
75549091560
-
Computer technology applications in surgical implant dentistry: a systematic review
-
Jung RE, Schneider D, Ganeles J, etal. Computer technology applications in surgical implant dentistry: a systematic review. Int J Oral Maxillofac Implants 2009; 24(Suppl):92-109.
-
(2009)
Int J Oral Maxillofac Implants
, vol.24
, pp. 92-109
-
-
Jung, R.E.1
Schneider, D.2
Ganeles, J.3
-
3
-
-
77649199482
-
Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study
-
Arisan V, Karabuda ZC, Ozdemir T. Accuracy of two stereolithographic guide systems for computer-aided implant placement: a computed tomography-based clinical comparative study. J Periodontol 2010; 81:43-51.
-
(2010)
J Periodontol
, vol.81
, pp. 43-51
-
-
Arisan, V.1
Karabuda, Z.C.2
Ozdemir, T.3
-
4
-
-
84858807469
-
A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae
-
D'Haese J, Van De Velde T, Elaut L, De Bruyn H. A prospective study on the accuracy of mucosally supported stereolithographic surgical guides in fully edentulous maxillae. Clin Implant Dent Relat Res 2012; 14:293-303.
-
(2012)
Clin Implant Dent Relat Res
, vol.14
, pp. 293-303
-
-
D'Haese, J.1
Van De Velde, T.2
Elaut, L.3
De Bruyn, H.4
-
5
-
-
49149088692
-
Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants
-
Ersoy AE, Turkyilmaz I, Ozan O, McGlumphy EA. Reliability of implant placement with stereolithographic surgical guides generated from computed tomography: clinical data from 94 implants. J Periodontol 2008; 79:1339-1345.
-
(2008)
J Periodontol
, vol.79
, pp. 1339-1345
-
-
Ersoy, A.E.1
Turkyilmaz, I.2
Ozan, O.3
McGlumphy, E.A.4
-
6
-
-
84864506897
-
Accuracy of virtually planned and template guided implant surgery on edentate patients
-
Pettersson A, Komiyama A, Hultin M, Nasstrom K, Klinge B. Accuracy of virtually planned and template guided implant surgery on edentate patients. Clin Implant Dent Relat Res 2013; 14:527-537.
-
(2013)
Clin Implant Dent Relat Res
, vol.14
, pp. 527-537
-
-
Pettersson, A.1
Komiyama, A.2
Hultin, M.3
Nasstrom, K.4
Klinge, B.5
-
7
-
-
80052067633
-
Computed tomography-based evaluation of template (NobelGuide)-guided implant positions: a prospective radiological study
-
Vasak C, Watzak G, Gahleitner A, Strbac G, Schemper M, Zechner W. Computed tomography-based evaluation of template (NobelGuide)-guided implant positions: a prospective radiological study. Clin Oral Implants Res 2011; 22:1157-1163.
-
(2011)
Clin Oral Implants Res
, vol.22
, pp. 1157-1163
-
-
Vasak, C.1
Watzak, G.2
Gahleitner, A.3
Strbac, G.4
Schemper, M.5
Zechner, W.6
-
8
-
-
0032173373
-
An image-guided planning system for endosseous oral implants
-
Verstreken K, Van Cleynenbreugel J, Martens K, Marchal G, van Steenberghe D, Suetens P. An image-guided planning system for endosseous oral implants. IEEE Trans Med Imaging 1998; 17:842-852.
-
(1998)
IEEE Trans Med Imaging
, vol.17
, pp. 842-852
-
-
Verstreken, K.1
Van Cleynenbreugel, J.2
Martens, K.3
Marchal, G.4
van Steenberghe, D.5
Suetens, P.6
-
9
-
-
80052048601
-
Calibrated segmentation of CBCT and CT images for digitization of dental prostheses
-
Wouters V, Mollemans W, Schutyser F. Calibrated segmentation of CBCT and CT images for digitization of dental prostheses. Int J Comput Assist Radiol Surg 2011; 6:609-616.
-
(2011)
Int J Comput Assist Radiol Surg
, vol.6
, pp. 609-616
-
-
Wouters, V.1
Mollemans, W.2
Schutyser, F.3
-
11
-
-
0036716301
-
A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report
-
van Steenberghe D, Naert I, Andersson M, Brajnovic I, Van Cleynenbreugel J, Suetens P. A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report. Int J Oral Maxillofac Implants 2002; 17:663-670.
-
(2002)
Int J Oral Maxillofac Implants
, vol.17
, pp. 663-670
-
-
van Steenberghe, D.1
Naert, I.2
Andersson, M.3
Brajnovic, I.4
Van Cleynenbreugel, J.5
Suetens, P.6
-
12
-
-
84995776832
-
A clinically relevant validation method for implant placement after virtual planning
-
Epub ahead of print.
-
Verhamme LM, Meijer GJ, Boumans T, Schutyser F, Berge SJ, Maal TJ. A clinically relevant validation method for implant placement after virtual planning. Clin Oral Implants Res 2012. Epub ahead of print.
-
(2012)
Clin Oral Implants Res
-
-
Verhamme, L.M.1
Meijer, G.J.2
Boumans, T.3
Schutyser, F.4
Berge, S.J.5
Maal, T.J.6
-
14
-
-
50949133388
-
Guided implant placement and immediate prosthesis delivery using traditional Branemark System abutments: a pilot study of 23 patients
-
Balshi SF, Wolfinger GJ, Balshi TJ. Guided implant placement and immediate prosthesis delivery using traditional Branemark System abutments: a pilot study of 23 patients. Implant Dent 2008; 17:128-135.
-
(2008)
Implant Dent
, vol.17
, pp. 128-135
-
-
Balshi, S.F.1
Wolfinger, G.J.2
Balshi, T.J.3
-
15
-
-
44949125661
-
Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery
-
Komiyama A, Klinge B, Hultin M. Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery. Clin Oral Implants Res 2008; 19:677-685.
-
(2008)
Clin Oral Implants Res
, vol.19
, pp. 677-685
-
-
Komiyama, A.1
Klinge, B.2
Hultin, M.3
-
16
-
-
34347344889
-
The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow-up period of thirteen months
-
Malo P, de Araujo Nobre M, Lopes A. The use of computer-guided flapless implant surgery and four implants placed in immediate function to support a fixed denture: preliminary results after a mean follow-up period of thirteen months. J Prosthet Dent 2007; 97:S26-S34.
-
(2007)
J Prosthet Dent
, vol.97
, pp. S26-S34
-
-
Malo, P.1
de Araujo Nobre, M.2
Lopes, A.3
-
17
-
-
29144465753
-
Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography
-
Hilgers ML, Scarfe WC, Scheetz JP, Farman AG. Accuracy of linear temporomandibular joint measurements with cone beam computed tomography and digital cephalometric radiography. Am J Orthod Dentofacial Orthop 2005; 128:803-811.
-
(2005)
Am J Orthod Dentofacial Orthop
, vol.128
, pp. 803-811
-
-
Hilgers, M.L.1
Scarfe, W.C.2
Scheetz, J.P.3
Farman, A.G.4
-
18
-
-
45949102819
-
Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
-
Ludlow JB, Ivanovic M. Comparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106:106-114.
-
(2008)
Oral Surg Oral Med Oral Pathol Oral Radiol Endod
, vol.106
, pp. 106-114
-
-
Ludlow, J.B.1
Ivanovic, M.2
-
19
-
-
34848918149
-
Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography
-
Moshiri M, Scarfe WC, Hilgers ML, Scheetz JP, Silveira AM, Farman AG. Accuracy of linear measurements from imaging plate and lateral cephalometric images derived from cone-beam computed tomography. Am J Orthod Dentofacial Orthop 2007; 132:550-560.
-
(2007)
Am J Orthod Dentofacial Orthop
, vol.132
, pp. 550-560
-
-
Moshiri, M.1
Scarfe, W.C.2
Hilgers, M.L.3
Scheetz, J.P.4
Silveira, A.M.5
Farman, A.G.6
-
20
-
-
52049117425
-
What is cone-beam CT and how does it work?
-
Scarfe WC, Farman AG. What is cone-beam CT and how does it work? Dent Clin North Am 2008; 52:707-730.
-
(2008)
Dent Clin North Am
, vol.52
, pp. 707-730
-
-
Scarfe, W.C.1
Farman, A.G.2
-
21
-
-
61649118441
-
Implant placement accuracy when using stereolithographic template as a surgical guide: preliminary results
-
Al-Harbi SA, Sun AY. Implant placement accuracy when using stereolithographic template as a surgical guide: preliminary results. Implant Dent 2009; 18:46-56.
-
(2009)
Implant Dent
, vol.18
, pp. 46-56
-
-
Al-Harbi, S.A.1
Sun, A.Y.2
-
22
-
-
84888641783
-
Conventional multi-slice Computed Tomography (CT) and Cone-Beam CT (CBCT) for computer-aided implant placement. Part II: reliability of mucosa-supported stereolithographic guides
-
Epub ahead of print.
-
Arisan V, Karabuda ZC, Piskin B, Ozdemir T. Conventional multi-slice Computed Tomography (CT) and Cone-Beam CT (CBCT) for computer-aided implant placement. Part II: reliability of mucosa-supported stereolithographic guides. Clin Implant Dent Relat Res 2012. Epub ahead of print.
-
(2012)
Clin Implant Dent Relat Res
-
-
Arisan, V.1
Karabuda, Z.C.2
Piskin, B.3
Ozdemir, T.4
-
23
-
-
37249018026
-
A model study on flapless implant placement by clinicians with a different experience level in implant surgery
-
de Velde TV, Glor F, Bruyn HD. A model study on flapless implant placement by clinicians with a different experience level in implant surgery. J Clin Oral Implant Res 2008; 19:66-72.
-
(2008)
J Clin Oral Implant Res
, vol.19
, pp. 66-72
-
-
de Velde, T.V.1
Glor, F.2
Bruyn, H.D.3
-
24
-
-
19044400459
-
Clinical application of stereolithographic surgical guides for implant placement: preliminary results
-
Di Giacomo GA, Cury PR, de Araujo NS, Sendyk WR, Sendyk CL. Clinical application of stereolithographic surgical guides for implant placement: preliminary results. J Periodontol 2005; 76:503-507.
-
(2005)
J Periodontol
, vol.76
, pp. 503-507
-
-
Di Giacomo, G.A.1
Cury, P.R.2
de Araujo, N.S.3
Sendyk, W.R.4
Sendyk, C.L.5
-
25
-
-
70350007810
-
Accuracy of a newly developed integrated system for dental implant planning
-
Dreiseidler T, Neugebauer J, Ritter L, etal. Accuracy of a newly developed integrated system for dental implant planning. J Clin Oral Implant Res 2009; 20:1191-1199.
-
(2009)
J Clin Oral Implant Res
, vol.20
, pp. 1191-1199
-
-
Dreiseidler, T.1
Neugebauer, J.2
Ritter, L.3
-
26
-
-
58149464557
-
Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement
-
Ozan O, Turkyilmaz I, Ersoy AE, McGlumphy EA, Rosenstiel SF. Clinical accuracy of 3 different types of computed tomography-derived stereolithographic surgical guides in implant placement. Int J Oral Maxillofac Surg 2009; 67:394-401.
-
(2009)
Int J Oral Maxillofac Surg
, vol.67
, pp. 394-401
-
-
Ozan, O.1
Turkyilmaz, I.2
Ersoy, A.E.3
McGlumphy, E.A.4
Rosenstiel, S.F.5
-
27
-
-
34548077180
-
Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study
-
Van Assche N, van Steenberghe D, Guerrero ME, etal. Accuracy of implant placement based on pre-surgical planning of three-dimensional cone-beam images: a pilot study. J Clin Periodontol 2007; 34:816-821.
-
(2007)
J Clin Periodontol
, vol.34
, pp. 816-821
-
-
Van Assche, N.1
van Steenberghe, D.2
Guerrero, M.E.3
-
28
-
-
77949759558
-
Accuracy assessment of computer-assisted flapless implant placement in partial edentulism
-
Van Assche N, van Steenberghe D, Quirynen M, Jacobs R. Accuracy assessment of computer-assisted flapless implant placement in partial edentulism. J Clin Periodontol 2010; 37:398-403.
-
(2010)
J Clin Periodontol
, vol.37
, pp. 398-403
-
-
Van Assche, N.1
van Steenberghe, D.2
Quirynen, M.3
Jacobs, R.4
-
29
-
-
0037292270
-
Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study
-
Vrielinck L, Politis C, Schepers S, Pauwels M, Naert U. Image-based planning and clinical validation of zygoma and pterygoid implant placement in patients with severe bone atrophy using customized drill guides. Preliminary results from a prospective clinical follow-up study. Int J Oral Maxillofac Surg 2003; 32:7-14.
-
(2003)
Int J Oral Maxillofac Surg
, vol.32
, pp. 7-14
-
-
Vrielinck, L.1
Politis, C.2
Schepers, S.3
Pauwels, M.4
Naert, U.5
-
30
-
-
77955154934
-
Flapless implant surgery in the edentulous jaw based on three fixed intraoral reference points and image-guided surgical templates: accuracy in human cadavers
-
Widmann G, Zangerl A, Keiler M, Stoffner R, Bale R, Puelacher W. Flapless implant surgery in the edentulous jaw based on three fixed intraoral reference points and image-guided surgical templates: accuracy in human cadavers. J Clin Oral Implant Res 2010; 21:835-841.
-
(2010)
J Clin Oral Implant Res
, vol.21
, pp. 835-841
-
-
Widmann, G.1
Zangerl, A.2
Keiler, M.3
Stoffner, R.4
Bale, R.5
Puelacher, W.6
-
31
-
-
38449096567
-
Pre-operative drilling simulation method for dental implant treatment
-
Arataki T, Furuya Y, Ito T, Miyashita Y, Shimamura I, Yajima Y. Pre-operative drilling simulation method for dental implant treatment. Bull Tokyo Dent Coll 2007; 48:27-35.
-
(2007)
Bull Tokyo Dent Coll
, vol.48
, pp. 27-35
-
-
Arataki, T.1
Furuya, Y.2
Ito, T.3
Miyashita, Y.4
Shimamura, I.5
Yajima, Y.6
-
32
-
-
84876105950
-
Tolerance within the sleeve inserts of different surgical guides for guided implant surgery
-
Koop R, Vercruyssen M, Vermeulen K, Quirynen M. Tolerance within the sleeve inserts of different surgical guides for guided implant surgery. Clin Oral Implants Res 2013; 24:630-634.
-
(2013)
Clin Oral Implants Res
, vol.24
, pp. 630-634
-
-
Koop, R.1
Vercruyssen, M.2
Vermeulen, K.3
Quirynen, M.4
-
33
-
-
84861813549
-
Deformation of stereolithographically produced surgical guides: an observational case series report
-
Stumpel LJ. Deformation of stereolithographically produced surgical guides: an observational case series report. Clin Implant Dent Relat Res 2012; 14:442-453.
-
(2012)
Clin Implant Dent Relat Res
, vol.14
, pp. 442-453
-
-
Stumpel, L.J.1
-
34
-
-
79952197372
-
Local anesthesia for cochlear implant surgery: a possible alternative
-
Hamerschmidt R, Mocellin M, Gasperin AC, etal. Local anesthesia for cochlear implant surgery: a possible alternative. Braz J Otorhinolaryngol 2010; 76:561-564.
-
(2010)
Braz J Otorhinolaryngol
, vol.76
, pp. 561-564
-
-
Hamerschmidt, R.1
Mocellin, M.2
Gasperin, A.C.3
-
35
-
-
70449698431
-
Computed tomography-guided surgery: complications associated with scanning, processing, surgery, and prosthetics
-
Block MS, Chandler C. Computed tomography-guided surgery: complications associated with scanning, processing, surgery, and prosthetics. J Oral Maxillofac Surg 2009; 67:13-22.
-
(2009)
J Oral Maxillofac Surg
, vol.67
, pp. 13-22
-
-
Block, M.S.1
Chandler, C.2
-
36
-
-
33646271340
-
Accuracy in computer-aided implant surgery - a review
-
Widmann G, Bale RJ. Accuracy in computer-aided implant surgery - a review. Int J Oral Maxillofac Implants 2006; 21:305-313.
-
(2006)
Int J Oral Maxillofac Implants
, vol.21
, pp. 305-313
-
-
Widmann, G.1
Bale, R.J.2
-
37
-
-
33645164549
-
Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept
-
Lal K, White GS, Morea DN, Wright RF. Use of stereolithographic templates for surgical and prosthodontic implant planning and placement. Part I. The concept. J Prosthodont 2006; 15:51-58.
-
(2006)
J Prosthodont
, vol.15
, pp. 51-58
-
-
Lal, K.1
White, G.S.2
Morea, D.N.3
Wright, R.F.4
-
39
-
-
79951792661
-
Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches
-
Nada RM, Maal TJ, Breuning KH, Berge SJ, Mostafa YA, Kuijpers-Jagtman AM. Accuracy and reproducibility of voxel based superimposition of cone beam computed tomography models on the anterior cranial base and the zygomatic arches. Plos One 2011; 6:e16520.
-
(2011)
Plos One
, vol.6
, pp. e16520
-
-
Nada, R.M.1
Maal, T.J.2
Breuning, K.H.3
Berge, S.J.4
Mostafa, Y.A.5
Kuijpers-Jagtman, A.M.6
-
41
-
-
69849086316
-
Accuracy of computer-aided oral implant surgery: a clinical and radiographic study
-
Valente F, Schiroli G, Sbrenna A. Accuracy of computer-aided oral implant surgery: a clinical and radiographic study. Int J Oral Maxillofac Implants 2009; 24:234-242.
-
(2009)
Int J Oral Maxillofac Implants
, vol.24
, pp. 234-242
-
-
Valente, F.1
Schiroli, G.2
Sbrenna, A.3
|