메뉴 건너뛰기




Volumn 38, Issue 1, 2013, Pages 148-153

Diffusion analysis with triexponential function in liver cirrhosis

Author keywords

apparent diffusion coefficient (ADC); cirrhosis; diffusion weighted imaging (DWI); intravoxel incoherent motion (IVIM); liver

Indexed keywords

GADOXETIC ACID;

EID: 84880118848     PISSN: 10531807     EISSN: 15222586     Source Type: Journal    
DOI: 10.1002/jmri.23966     Document Type: Article
Times cited : (41)

References (20)
  • 1
    • 21244495674 scopus 로고    scopus 로고
    • Apparent diffusion coefficient measurements with diffusion-weighted magnetic resonance imaging for evaluation of hepatic fibrosis
    • Koinuma M, Ohashi I, Hanafusa K, Shibuya H,. Apparent diffusion coefficient measurements with diffusion-weighted magnetic resonance imaging for evaluation of hepatic fibrosis. J Magn Reson Imaging 2005; 22: 80-85.
    • (2005) J Magn Reson Imaging , vol.22 , pp. 80-85
    • Koinuma, M.1    Ohashi, I.2    Hanafusa, K.3    Shibuya, H.4
  • 2
    • 34748912281 scopus 로고    scopus 로고
    • Diffusion-weighted MRI for quantification of liver fibrosis: Preliminary experience
    • Taouli B, Tolia AJ, Losada M, et al. Diffusion-weighted MRI for quantification of liver fibrosis: preliminary experience. AJR Am J Roentgenol 2007; 189: 799-806.
    • (2007) AJR Am J Roentgenol , vol.189 , pp. 799-806
    • Taouli, B.1    Tolia, A.J.2    Losada, M.3
  • 3
    • 34548729089 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C
    • Lewin M, Poujol-Robert A, Boelle PY, et al. Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C. Hepatology 2007; 46: 658-665.
    • (2007) Hepatology , vol.46 , pp. 658-665
    • Lewin, M.1    Poujol-Robert, A.2    Boelle, P.Y.3
  • 4
    • 61349123591 scopus 로고    scopus 로고
    • Diffusion-weighted magnetic resonance imaging as a cancer biomarker: Consensus and recommendations
    • Padhani AR, Liu G, Koh DM, et al. Diffusion-weighted magnetic resonance imaging as a cancer biomarker: consensus and recommendations. Neoplasia 2009; 11: 102-125.
    • (2009) Neoplasia , vol.11 , pp. 102-125
    • Padhani, A.R.1    Liu, G.2    Koh, D.M.3
  • 5
    • 77954117330 scopus 로고    scopus 로고
    • Utility of diffusion-weighted MRI in distinguishing benign and malignant hepatic lesions
    • Miller FH, Hammond N, Siddiqi AJ, et al. Utility of diffusion-weighted MRI in distinguishing benign and malignant hepatic lesions. J Magn Reson Imaging 2010; 32: 138-147.
    • (2010) J Magn Reson Imaging , vol.32 , pp. 138-147
    • Miller, F.H.1    Hammond, N.2    Siddiqi, A.J.3
  • 7
    • 0028958198 scopus 로고
    • In vivo measurement of diffusion and pseudo-diffusion in skeletal muscle at rest and after exercise
    • Morvan D,. In vivo measurement of diffusion and pseudo-diffusion in skeletal muscle at rest and after exercise. Magn Reson Imaging 1995; 13: 193-199.
    • (1995) Magn Reson Imaging , vol.13 , pp. 193-199
    • Morvan, D.1
  • 8
    • 0032975435 scopus 로고    scopus 로고
    • Diffusion coefficients in abdominal organs and hepatic lesions: Evaluation with intravoxel incoherent motion echo-planar MR imaging
    • Yamada I, Aung W, Himeno Y, et al. Diffusion coefficients in abdominal organs and hepatic lesions: evaluation with intravoxel incoherent motion echo-planar MR imaging. Radiology 1999; 210: 617-623.
    • (1999) Radiology , vol.210 , pp. 617-623
    • Yamada, I.1    Aung, W.2    Himeno, Y.3
  • 9
    • 0033979361 scopus 로고    scopus 로고
    • In vivo intravoxel incoherent motion measurements in the human placenta using echo-planar imaging at 0.5 T
    • Moore RJ, Issa B, Tokarczuk P, et al. In vivo intravoxel incoherent motion measurements in the human placenta using echo-planar imaging at 0.5 T. Magn Reson Med 2000; 43: 295-302.
    • (2000) Magn Reson Med , vol.43 , pp. 295-302
    • Moore, R.J.1    Issa, B.2    Tokarczuk, P.3
  • 10
    • 58149179092 scopus 로고    scopus 로고
    • Liver cirrhosis: Intravoxel incoherent motion MR imaging-pilot study
    • Luciani A, Vignaud A, Cavet M, et al. Liver cirrhosis: intravoxel incoherent motion MR imaging-pilot study. Radiology 2008; 249: 891-899.
    • (2008) Radiology , vol.249 , pp. 891-899
    • Luciani, A.1    Vignaud, A.2    Cavet, M.3
  • 11
    • 77649216180 scopus 로고    scopus 로고
    • Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast-enhanced MRI alone and in combination: Preliminary experience
    • Patel J, Sigmund EE, Rusinek H, Oei M, Babb JS, Taouli B,. Diagnosis of cirrhosis with intravoxel incoherent motion diffusion MRI and dynamic contrast-enhanced MRI alone and in combination: preliminary experience. J Magn Reson Imaging 2010; 31: 589-600.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 589-600
    • Patel, J.1    Sigmund, E.E.2    Rusinek, H.3    Oei, M.4    Babb, J.S.5    Taouli, B.6
  • 12
    • 79954950167 scopus 로고    scopus 로고
    • Intravoxel incoherent motion imaging of tumor microenvironment in locally advanced breast cancer
    • Sigmund EE, Cho GY, Kim S, et al. Intravoxel incoherent motion imaging of tumor microenvironment in locally advanced breast cancer. Magn Reson Med 2011; 65: 1437-1447.
    • (2011) Magn Reson Med , vol.65 , pp. 1437-1447
    • Sigmund, E.E.1    Cho, G.Y.2    Kim, S.3
  • 13
    • 48649088802 scopus 로고    scopus 로고
    • Biexponential analysis of diffusion-related signal decay in normal human cortical and deep gray matter
    • Maier SE, Mulkern RV,. Biexponential analysis of diffusion-related signal decay in normal human cortical and deep gray matter. Magn Reson Imaging 2008; 26: 897-904.
    • (2008) Magn Reson Imaging , vol.26 , pp. 897-904
    • Maier, S.E.1    Mulkern, R.V.2
  • 14
    • 37349021659 scopus 로고    scopus 로고
    • In vivo visualization of displacement-distribution-derived parameters in q-space imaging
    • Lätt J, Nilsson M, Wirestam R, et al. In vivo visualization of displacement-distribution-derived parameters in q-space imaging. Magn Reson Imaging 2008; 26: 77-87.
    • (2008) Magn Reson Imaging , vol.26 , pp. 77-87
    • Lätt, J.1    Nilsson, M.2    Wirestam, R.3
  • 15
    • 69449085107 scopus 로고    scopus 로고
    • Diffusion-weighted imaging of the liver: Comparison of navigator triggered and breathhold acquisitions
    • Taouli B, Sandberg A, Stemmer A, et al. Diffusion-weighted imaging of the liver: comparison of navigator triggered and breathhold acquisitions. J Magn Reson Imaging 2009; 30: 561-568.
    • (2009) J Magn Reson Imaging , vol.30 , pp. 561-568
    • Taouli, B.1    Sandberg, A.2    Stemmer, A.3
  • 16
    • 0036263907 scopus 로고    scopus 로고
    • Generalized autocalibrating partially parallel acquisitions (GRAPPA)
    • Griswold MA, Jakob PM, Heidemann RM, et al. Generalized autocalibrating partially parallel acquisitions (GRAPPA). Magn Reson Med 2002; 47: 1202-1210.
    • (2002) Magn Reson Med , vol.47 , pp. 1202-1210
    • Griswold, M.A.1    Jakob, P.M.2    Heidemann, R.M.3
  • 17
    • 0000169232 scopus 로고
    • An algorithm for least-squares estimation of nonlinear parameters
    • Marquardt DW,. An algorithm for least-squares estimation of nonlinear parameters. J Soc Indust Appl Math 1963; 11: 431-441.
    • (1963) J Soc Indust Appl Math , vol.11 , pp. 431-441
    • Marquardt, D.W.1
  • 19
    • 0035115565 scopus 로고    scopus 로고
    • Hepatic perfusion parameters in chronic liver disease: Dynamic CT measurements correlated with disease severity
    • Van Beers BE, Leconte I, Materne R, Smith AM, Jamart J, Horsmans Y,. Hepatic perfusion parameters in chronic liver disease: dynamic CT measurements correlated with disease severity. AJR Am J Roentgenol 2001; 176: 667-673.
    • (2001) AJR Am J Roentgenol , vol.176 , pp. 667-673
    • Van Beers, B.E.1    Leconte, I.2    Materne, R.3    Smith, A.M.4    Jamart, J.5    Horsmans, Y.6
  • 20
    • 79959268185 scopus 로고    scopus 로고
    • Magnetic resonance diffusion-weighted imaging: Quantitative evaluation of age-related changes in healthy liver parenchyma
    • Pasquinelli F, Belli G, Mazzoni LN, Grazioli L, Colagrande S,. Magnetic resonance diffusion-weighted imaging: quantitative evaluation of age-related changes in healthy liver parenchyma. Magn Reson Imaging 2011; 29: 805-812.
    • (2011) Magn Reson Imaging , vol.29 , pp. 805-812
    • Pasquinelli, F.1    Belli, G.2    Mazzoni, L.N.3    Grazioli, L.4    Colagrande, S.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.