메뉴 건너뛰기




Volumn 144, Issue 1, 2013, Pages 193-199

Biodegradable cisplatin-eluting tracheal stent for malignant airway obstruction: In vivo and in vitro studies

Author keywords

[No Author keywords available]

Indexed keywords

CISPLATIN; POLYCAPROLACTONE; POLYGLACTIN;

EID: 84880050058     PISSN: 00123692     EISSN: 19313543     Source Type: Journal    
DOI: 10.1378/chest.12-2282     Document Type: Article
Times cited : (71)

References (17)
  • 2
    • 33947317627 scopus 로고    scopus 로고
    • Long-term follow-up of Ultraflex metallic stents in benign and malignant central airway obstruction
    • Husain SA, Finch D, Ahmed M, Morgan A, Hetzel MR. Long-term follow-up of Ultraflex metallic stents in benign and malignant central airway obstruction. Ann Thorac Surg. 2007; 83 (4): 1251-1256.
    • (2007) Ann Thorac Surg , vol.83 , Issue.4 , pp. 1251-1256
    • Husain, S.A.1    Finch, D.2    Ahmed, M.3    Morgan, A.4    Hetzel, M.R.5
  • 3
    • 67650481848 scopus 로고    scopus 로고
    • Palliative treatment of inoperable malignant tracheobronchial obstruction: Temporary stenting combined with radiation therapy and/or chemotherapy
    • Kim JH, Shin JH, Song HY, et al. Palliative treatment of inoperable malignant tracheobronchial obstruction: temporary stenting combined with radiation therapy and/or chemotherapy. AJR Am J Roentgenol. 2009; 193 (1): W38-42.
    • (2009) AJR Am J Roentgenol , vol.193 , Issue.1
    • Kim, J.H.1    Shin, J.H.2    Song, H.Y.3
  • 4
    • 22544446431 scopus 로고    scopus 로고
    • Outcomes of tracheobronchial stents in patients with malignant airway disease
    • Lemaire A, Burfeind WR, Toloza E, et al. Outcomes of tracheobronchial stents in patients with malignant airway disease. Ann Thorac Surg. 2005; 80 (2): 434-437.
    • (2005) Ann Thorac Surg , vol.80 , Issue.2 , pp. 434-437
    • Lemaire, A.1    Burfeind, W.R.2    Toloza, E.3
  • 5
    • 84859832521 scopus 로고    scopus 로고
    • Safety and efficacy of thoracic external beam radiotherapy after airway stenting in malignant airway obstruction
    • Rochet N, Hauswald H, Schmaus M, et al. Safety and efficacy of thoracic external beam radiotherapy after airway stenting in malignant airway obstruction. Int J Radiat Oncol Biol Phys. 2012; 83 (1): e129-e135.
    • (2012) Int J Radiat Oncol Biol Phys , vol.83 , Issue.1
    • Rochet, N.1    Hauswald, H.2    Schmaus, M.3
  • 6
    • 56249106830 scopus 로고    scopus 로고
    • Factors leading to tracheobronchial self-expandable metallic stent fracture
    • Chung FT, Lin SM, Chen HC, et al. Factors leading to tracheobronchial self-expandable metallic stent fracture. J Thorac Cardiovasc Surg. 2008; 136 (5): 1328-1335.
    • (2008) J Thorac Cardiovasc Surg , vol.136 , Issue.5 , pp. 1328-1335
    • Chung, F.T.1    Lin, S.M.2    Chen, H.C.3
  • 7
    • 9344237660 scopus 로고    scopus 로고
    • Medium-term follow-up after deployment of Ultraflex expandable metallic stents to manage endobronchial pathology
    • Madden BP, Park JE, Sheth A. Medium-term follow-up after deployment of Ultraflex expandable metallic stents to manage endobronchial pathology. Ann Thorac Surg. 2004; 78 (6): 1898-1902.
    • (2004) Ann Thorac Surg , vol.78 , Issue.6 , pp. 1898-1902
    • Madden, B.P.1    Park, J.E.2    Sheth, A.3
  • 8
    • 45649084306 scopus 로고    scopus 로고
    • Bronchoscopic intratumoral chemotherapy of lung cancer
    • Celikoglu F, Celikoglu SI, Goldberg EP. Bronchoscopic intratumoral chemotherapy of lung cancer. Lung Cancer. 2008; 61 (1): 1-12.
    • (2008) Lung Cancer , vol.61 , Issue.1 , pp. 1-12
    • Celikoglu, F.1    Celikoglu, S.I.2    Goldberg, E.P.3
  • 9
    • 31344452153 scopus 로고    scopus 로고
    • Intratumoral administration of cisplatin through a bronchoscope followed by irradiation for treatment of inoperable non-small cell obstructive lung cancer
    • Celikoglu F, Celikoglu SI, York AM, Goldberg EP. Intratumoral administration of cisplatin through a bronchoscope followed by irradiation for treatment of inoperable non-small cell obstructive lung cancer. Lung Cancer. 2006; 51 (2): 225-236.
    • (2006) Lung Cancer , vol.51 , Issue.2 , pp. 225-236
    • Celikoglu, F.1    Celikoglu, S.I.2    York, A.M.3    Goldberg, E.P.4
  • 10
    • 33750427308 scopus 로고    scopus 로고
    • Endobronchial intratumoral chemotherapy (EITC) followed by surgery in early non-small cell lung cancer with polypoid growth causing erroneous impression of advanced disease
    • Celikoglu SI, Celikoglu F, Goldberg EP. Endobronchial intratumoral chemotherapy (EITC) followed by surgery in early non-small cell lung cancer with polypoid growth causing erroneous impression of advanced disease. Lung Cancer. 2006; 54 (3): 339-346.
    • (2006) Lung Cancer , vol.54 , Issue.3 , pp. 339-346
    • Celikoglu, S.I.1    Celikoglu, F.2    Goldberg, E.P.3
  • 11
    • 0032779478 scopus 로고    scopus 로고
    • Drug retention and distribution after intratumoral chemotherapy with fluorouracil/epinephrine injectable gel in human pancreatic cancer xenografts
    • Smith JP, Kanekal S, Patawaran MB, et al. Drug retention and distribution after intratumoral chemotherapy with fluorouracil/epinephrine injectable gel in human pancreatic cancer xenografts. Cancer Chemother Pharmacol. 1999; 44 (4): 267-274.
    • (1999) Cancer Chemother Pharmacol , vol.44 , Issue.4 , pp. 267-274
    • Smith, J.P.1    Kanekal, S.2    Patawaran, M.B.3
  • 12
    • 77956741357 scopus 로고    scopus 로고
    • Fabrication of balloon-expandable self-lock drug-eluting polycaprolactone stents using micro-injection molding and spray coating techniques
    • Liu SJ, Chiang FJ, Hsiao CY, Kau YC, Liu KS. Fabrication of balloon-expandable self-lock drug-eluting polycaprolactone stents using micro-injection molding and spray coating techniques. Ann Biomed Eng. 2010; 38 (10): 3185-3194.
    • (2010) Ann Biomed Eng , vol.38 , Issue.10 , pp. 3185-3194
    • Liu, S.J.1    Chiang, F.J.2    Hsiao, C.Y.3    Kau, Y.C.4    Liu, K.S.5
  • 13
    • 78751505440 scopus 로고    scopus 로고
    • Experimental absorbable stent permits airway remodeling
    • Liu KS, Liu YH, Peng YJ, Liu SJ. Experimental absorbable stent permits airway remodeling. J Thorac Cardiovasc Surg. 2011; 141 (2): 463-468.
    • (2011) J Thorac Cardiovasc Surg , vol.141 , Issue.2 , pp. 463-468
    • Liu, K.S.1    Liu, Y.H.2    Peng, Y.J.3    Liu, S.J.4
  • 14
    • 0036381814 scopus 로고    scopus 로고
    • New tubular bioabsorbable knitted airway stent: Biocompatibility and mechanical strength
    • Saito Y, Minami K, Kobayashi M, et al. New tubular bioabsorbable knitted airway stent: biocompatibility and mechanical strength. J Thorac Cardiovasc Surg. 2002; 123 (1): 161-167.
    • (2002) J Thorac Cardiovasc Surg , vol.123 , Issue.1 , pp. 161-167
    • Saito, Y.1    Minami, K.2    Kobayashi, M.3
  • 16
    • 0037452233 scopus 로고    scopus 로고
    • Drug-eluting stents in vascular intervention
    • Fattori R, Piva T. Drug-eluting stents in vascular intervention. Lancet. 2003; 361 (9353): 247-249.
    • (2003) Lancet , vol.361 , Issue.9353 , pp. 247-249
    • Fattori, R.1    Piva, T.2
  • 17
    • 84855369256 scopus 로고    scopus 로고
    • Development of nanofiber coated indomethacin-eluting stent for tracheal regeneration
    • Heo DN, Lee JB, Bae MS, Hwang YS, Kwon KH, Kwon IK. Development of nanofiber coated indomethacin-eluting stent for tracheal regeneration. J Nanosci Nanotechnol. 2011; 11( 7): 5711-5716.
    • (2011) J Nanosci Nanotechnol , vol.11 , Issue.7 , pp. 5711-5716
    • Heo, D.N.1    Lee, J.B.2    Bae, M.S.3    Hwang, Y.S.4    Kwon, K.H.5    Kwon, I.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.