메뉴 건너뛰기




Volumn 60, Issue 7, 2013, Pages 1900-1911

Removing ballistocardiogram artifact from EEG using short-and long-term linear predictor

Author keywords

Artifact removal; ballistocardiogram (BCG); blind source extraction (BSE); linear prediction

Indexed keywords

ARTIFACT REMOVAL; BALLISTOCARDIOGRAM (BCG); BLIND SOURCE EXTRACTION; BLIND SOURCE EXTRACTION (BSE); FUNCTIONAL MAGNETIC RESONANCE IMAGING; LINEAR PREDICTION; LINEAR PREDICTION TECHNIQUES; SHORT TERM PREDICTION;

EID: 84879985695     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.2013.2244888     Document Type: Article
Times cited : (28)

References (36)
  • 1
    • 0032189998 scopus 로고    scopus 로고
    • Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction
    • DOI 10.1006/nimg.1998.0361
    • P. J. Allen, G. Polizzi, K. Krakow, D. R. Fish, and L. Lemieux, "Identification of EEG events in the MR scanner: The problem of pulse artifact and a method for its subtraction," Neuroimage, vol. 8, no. 3, pp. 229-239, 1998. (Pubitemid 28476231)
    • (1998) NeuroImage , vol.8 , Issue.3 , pp. 229-239
    • Allen, P.J.1    Polizzi, G.2    Krakow, K.3    Fish, D.R.4    Lemieux, L.5
  • 2
    • 0033870442 scopus 로고    scopus 로고
    • A method for removing imaging artifact from continuous EEG recorded during functional MRI
    • DOI 10.1006/nimg.2000.0599
    • P. J. Allen, O. Josephs, and R. Turner, "A method for removing imaging artifact from continuous EEG recorded during functionalMRI," Neuroimage, vol. 12, no. 2, pp. 230-239, 2000. (Pubitemid 30627023)
    • (2000) NeuroImage , vol.12 , Issue.2 , pp. 230-239
    • Allen, P.J.1    Josephs, O.2    Turner, R.3
  • 3
    • 0036679097 scopus 로고    scopus 로고
    • Motion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI
    • G. Bonmassar, P. L. Purdon, I. P. Jskelinen, K. Chiappa, V. Solo, E. N. Brown, and J. W. Belliveau, "Motion and ballistocardiogram artifact removal for interleaved recording of EEG and EPs during MRI," Neuroimage, vol. 16, no. 4, pp. 1127-1141, 2002.
    • (2002) Neuroimage , vol.16 , Issue.4 , pp. 1127-1141
    • Bonmassar, G.1    Purdon, P.L.2    Jskelinen, I.P.3    Chiappa, K.4    Solo, V.5    Brown, E.N.6    Belliveau, J.W.7
  • 4
    • 0033867418 scopus 로고    scopus 로고
    • Recording of the event-related potentials during functional MRI at 3.0 tesla field strength
    • DOI 10.1002/1522-2594(200008)44:2<277::AID-MRM15>3.0.CO;2-X
    • F. Kruggel, C. J. Wiggins, C. S. Herrmann, and D. Y. von Cramon, "Recording of the event-related potentials during functional MRI at 3.0 Tesla field strength," Mag. Reson. Med., vol. 44, no. 2, pp. 277-282, 2000. (Pubitemid 30614787)
    • (2000) Magnetic Resonance in Medicine , vol.44 , Issue.2 , pp. 277-282
    • Kruggel, F.1    Wiggins, C.J.2    Herrmann, C.S.3    Von Cramon, D.Y.4
  • 5
    • 35148848284 scopus 로고    scopus 로고
    • Artifact removal in co-registered EEG/fMRI by selective average subtraction
    • DOI 10.1016/j.clinph.2007.08.017, PII S1388245707004154
    • S. Gonçalves, P. Pouwels, J. Kuijer, R. Heethaar, and J. de Munck, "Artifact removal in coregistered EEG/fMRI by selective average subtraction," Clin. Neurophysiol., vol. 118, no. 11, pp. 2437-2450, 2007. (Pubitemid 47539266)
    • (2007) Clinical Neurophysiology , vol.118 , Issue.11 , pp. 2437-2450
    • Goncalves, S.I.1    Pouwels, P.J.W.2    Kuijer, J.P.A.3    Heethaar, R.M.4    De Munck, J.C.5
  • 6
    • 27544446124 scopus 로고    scopus 로고
    • Removal of FMRI environment artifacts from EEG data using optimal basis sets
    • DOI 10.1016/j.neuroimage.2005.06.067, PII S1053811905004726
    • R. K.Niazy,C. F.Beckmann, G. D. Iannetti, J. M. Brady, and S. M. Smith, "Removal of fMRI environment artifacts from EEG data using optimal basis sets," Neuroimage, vol. 28, no. 3, pp. 720-737, 2005. (Pubitemid 41541965)
    • (2005) NeuroImage , vol.28 , Issue.3 , pp. 720-737
    • Niazy, R.K.1    Beckmann, C.F.2    Iannetti, G.D.3    Brady, J.M.4    Smith, S.M.5
  • 7
    • 34547831040 scopus 로고    scopus 로고
    • Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: Removal of the ballistocardiogram artefact
    • DOI 10.1016/j.neuroimage.2006.09.031, PII S1053811906009827
    • S. Debener, A. Strobel, B. Sorger, J. Peters, C. Kranczioch, A. K. Engel, and R. Goebel, "Improved quality of auditory event-related potentials recorded simultaneously with 3-T fMRI: Removal of the ballistocardiogram artefact," Neuroimage, vol. 34, no. 2, pp. 587-597, 2007. (Pubitemid 44827764)
    • (2007) NeuroImage , vol.34 , Issue.2 , pp. 587-597
    • Debener, S.1    Strobel, A.2    Sorger, B.3    Peters, J.4    Kranczioch, C.5    Engel, A.K.6    Goebel, R.7
  • 8
    • 39449090982 scopus 로고    scopus 로고
    • Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 T static magnetic field strength
    • DOI 10.1016/j.ijpsycho.2007.05.015, PII S0167876007001584
    • S. Debener, K. J. Mullinger, R. K. Niazy, and R. W. Bowtell, "Properties of the ballistocardiogram artefact as revealed by EEG recordings at 1.5, 3 and 7 t static magnetic field strength," Int. J. Psychophysiol., vol. 67, no. 3, pp. 189-199, 2008. (Pubitemid 351273440)
    • (2008) International Journal of Psychophysiology , vol.67 , Issue.3 , pp. 189-199
    • Debener, S.1    Mullinger, K.J.2    Niazy, R.K.3    Bowtell, R.W.4
  • 10
    • 10044290880 scopus 로고    scopus 로고
    • ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner
    • DOI 10.1016/j.neuroimage.2004.09.041, PII S1053811904005683
    • G. Srivastava, S. Crottaz-Herbette, K. Lau, G. Glover, and V. Menon, "ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner," Neuroimage, vol. 24, no. 1, pp. 50-60, 2005. (Pubitemid 39611025)
    • (2005) NeuroImage , vol.24 , Issue.1 , pp. 50-60
    • Srivastava, G.1    Crottaz-Herbette, S.2    Lau, K.M.3    Glover, G.H.4    Menon, V.5
  • 11
    • 33746829245 scopus 로고    scopus 로고
    • Removal of ballistocardiogram artifacts from simultaneously recorded EEG and fMRI data using independent component analysis
    • DOI 10.1109/TBME.2006.875718, 1643399
    • W. Nakamura, K. Anami, T. Mori, O. Saitoh, A. Cichocki, and S. Amari, "Removal of ballistocardiogram artifacts from simultaneously recorded EEG and fMRI data using independent component analysis," IEEE Trans. Biomed. Eng., vol. 53, no. 7, pp. 1294-1308, Jul. 2006. (Pubitemid 44172304)
    • (2006) IEEE Transactions on Biomedical Engineering , vol.53 , Issue.7 , pp. 1294-1308
    • Nakamura, W.1    Anami, K.2    Mori, T.3    Saitoh, O.4    Cichocki, A.5    Amari, S.-I.6
  • 12
    • 35148821509 scopus 로고    scopus 로고
    • Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis
    • DOI 10.1016/j.neuroimage.2006.09.037, PII S1053811906009761
    • D. Mantini, M. G. Perrucci, S. Cugini, A. Ferretti, G. L. Romani, and G. C. D. , "Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis," Neuroimage, vol. 34, no. 2, pp. 598-607, 2007. (Pubitemid 44827763)
    • (2007) NeuroImage , vol.34 , Issue.2 , pp. 598-607
    • Mantini, D.1    Perrucci, M.G.2    Cugini, S.3    Ferretti, A.4    Romani, G.L.5    Del Gratta, C.6
  • 13
    • 63849178784 scopus 로고    scopus 로고
    • Removal of BCG artifacts using a non-Kirchhoffian overcomplete representation
    • Feb
    • M. Dyrholm, R. Goldman, P. Sajda, and T. R. Brown, "Removal of BCG artifacts using a non-Kirchhoffian overcomplete representation," IEEE Trans. Biomed. Eng., vol. 56, no. 2, pp. 200-204, Feb. 2009.
    • (2009) IEEE Trans. Biomed. Eng , vol.56 , Issue.2 , pp. 200-204
    • Dyrholm, M.1    Goldman, R.2    Sajda, P.3    Brown, T.R.4
  • 14
    • 77958149988 scopus 로고    scopus 로고
    • Removal of ballistocardiogram artifacts using the cyclostationary source extraction method
    • Jul.
    • F. Ghaderi, K. Nazarpour, J. G. McWhirter, and S. Sanei, "Removal of ballistocardiogram artifacts using the cyclostationary source extraction method," IEEE Trans. Biomed. Eng., vol. 57, no. 11, pp. 2667-2676, Jul. 2010.
    • (2010) IEEE Trans. Biomed. Eng , vol.57 , Issue.11 , pp. 2667-2676
    • Ghaderi, F.1    Nazarpour, K.2    McWhirter, J.G.3    Sanei, S.4
  • 15
    • 57649223683 scopus 로고    scopus 로고
    • Rejection of pulse related artefact (PRA) from continuous electroencephalographic (EEG) time series recorded during functional magnetic resonance imaging (fMRI) using constraint independent component analysis (cICA)
    • Y. Leclercq, E. Balteau, T. Dang-Vu, M. Schabus, A. Luxen, P. Maquet, and C. Phillips, "Rejection of pulse related artefact (PRA) from continuous electroencephalographic (EEG) time series recorded during functional magnetic resonance imaging (fMRI) using constraint independent component analysis (cICA)," Neuroimage, vol. 44, no. 3, pp. 679-691, 2009.
    • (2009) Neuroimage , vol.44 , Issue.3 , pp. 679-691
    • Leclercq, Y.1    Balteau, E.2    Dang-Vu, T.3    Schabus, M.4    Luxen, A.5    Maquet, P.6    Phillips, C.7
  • 17
    • 0035458448 scopus 로고    scopus 로고
    • Extraction of specific signals with temporal structure
    • DOI 10.1162/089976601750399272
    • A. K. Barros and A. Cichocki, "Extraction of specific signals with temporal structure," Neural Comput., vol. 13, pp. 1995-2003, 2001. (Pubitemid 33595039)
    • (2001) Neural Computation , vol.13 , Issue.9 , pp. 1995-2003
    • Barros, A.K.1    Cichocki, A.2
  • 18
    • 0034245419 scopus 로고    scopus 로고
    • On-line algorithm for blind signal extraction of arbitrarily distributed, but temporally correlated sources using second order statistics
    • A. Cichocki and R. Thawonmas, "On-line algorithm for blind signal extraction of arbitrarily distributed, but temporally correlated sources using second order statistics," Neural Process. Lett., vol. 12, no. 1, pp. 91-98, 2000.
    • (2000) Neural Process. Lett , vol.12 , Issue.1 , pp. 91-98
    • Cichocki, A.1    Thawonmas, R.2
  • 19
    • 34249992846 scopus 로고    scopus 로고
    • Blind source extraction based on a linear predictor
    • DOI 10.1049/iet-spr:20060263
    • W. Liu, D. P. Mandic, and A. Cichocki, "Blind source extraction based on a linear predictor," IET Signal Process., vol. 1, no. 1, pp. 29-34, Mar. 2007. (Pubitemid 46883287)
    • (2007) IET Signal Processing , vol.1 , Issue.1 , pp. 29-34
    • Liu, W.1    Mandic, D.P.2    Cichocki, A.3
  • 20
    • 0029411030 scopus 로고
    • An information-maximization approach to blind separation and blind deconvolution
    • A. J. Bell and T. J. Sejnowski, "An information-maximization approach to blind separation and blind deconvolution," Neural Comput., vol. 7, no. 6, pp. 1129-1159, 1995.
    • (1995) Neural Comput , vol.7 , Issue.6 , pp. 1129-1159
    • Bell, A.J.1    Sejnowski, T.J.2
  • 22
    • 0027812550 scopus 로고
    • Blind beamforming for non-Gaussian signals
    • Dec
    • J.-F. Cardoso and A. Souloumiac, "Blind beamforming for non-Gaussian signals," IEE Proc. F Radar Signal Process., vol. 140, no. 6, pp. 362-370, Dec. 1993.
    • (1993) IEE Proc. F Radar Signal Process , vol.140 , Issue.6 , pp. 362-370
    • Cardoso, J.-F.1    Souloumiac, A.2
  • 23
    • 0031078854 scopus 로고    scopus 로고
    • A blind source separation technique using second-order statistics
    • Feb
    • A. Belouchrani, K. Abed-Meraim, J. F. Cardoso, and E. Moulines, "A blind source separation technique using second-order statistics," IEEE Trans. Signal Process., vol. 45, no. 2, pp. 434-444, Feb. 2002.
    • (2002) IEEE Trans. Signal Process , vol.45 , Issue.2 , pp. 434-444
    • Belouchrani, A.1    Abed-Meraim, K.2    Cardoso, J.F.3    Moulines, E.4
  • 24
    • 33646156411 scopus 로고    scopus 로고
    • A normalised kurtosis-based algorithm for blind source extraction from noisy measurements
    • W. Liu and D. P. Mandic, "A normalised kurtosis-based algorithm for blind source extraction from noisy measurements," Signal Process., vol. 86, no. 7, pp. 1580-1585, 2006.
    • (2006) Signal Process , vol.86 , Issue.7 , pp. 1580-1585
    • Liu, W.1    Mandic, D.P.2
  • 25
    • 10044290880 scopus 로고    scopus 로고
    • ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner
    • DOI 10.1016/j.neuroimage.2004.09.041, PII S1053811904005683
    • G. Srivastava, S. Crottaz-Herbette, K. Lau, G. Glover, and V. Menon, "ICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner," Neuroimage, vol. 24, no. 1, pp. 50-60, 2005. (Pubitemid 39611025)
    • (2005) NeuroImage , vol.24 , Issue.1 , pp. 50-60
    • Srivastava, G.1    Crottaz-Herbette, S.2    Lau, K.M.3    Glover, G.H.4    Menon, V.5
  • 26
    • 0035878735 scopus 로고    scopus 로고
    • Removal of ECG interference from the EEG recordings in small animals using independent component analysis
    • DOI 10.1016/S0165-0270(01)00366-1, PII S0165027001003661
    • S. Tong, A. Bezerianos, J. Paul, Y. Zhu, and N. Thakor, "Removal of ECG interference from the EEG recordings in small animals using independent component analysis," J. Neurosci. Methods, vol. 108, no. 1, pp. 11-17, 2001. (Pubitemid 32664037)
    • (2001) Journal of Neuroscience Methods , vol.108 , Issue.1 , pp. 11-17
    • Tong, S.1    Bezerianos, A.2    Paul, J.3    Zhu, Y.4    Thakor, N.5
  • 27
    • 57249115897 scopus 로고    scopus 로고
    • Contextual movement constraints of others modulate motor preparation in the observer
    • R. Liepelt, M. Ullsperger, K. Obst, S. Spengler, D. von Cramon, and M. Brass, "Contextual movement constraints of others modulate motor preparation in the observer," Neuropsychologia, vol. 47, no. 1, pp. 268-275, 2009.
    • (2009) Neuropsychologia , vol.47 , Issue.1 , pp. 268-275
    • Liepelt, R.1    Ullsperger, M.2    Obst, K.3    Spengler, S.4    Von Cramon, D.5    Brass, M.6
  • 28
    • 0017068874 scopus 로고
    • Voluntary finger movement in man: Cerebral potentials and theory
    • L. Deecke and B. Gr̈ozinger, H. Kornhuber, "Voluntary finger movement in man: Cerebral potentials and theory," Biol.Cybern., vol. 23, pp. 99-119, 1976.
    • (1976) Biol.Cybern , vol.23 , pp. 99-119
    • Deecke, L.1    Gr̈ozinger, B.2    Kornhuber, H.3
  • 29
    • 34250560897 scopus 로고
    • Electrocorticograms in man: Effect of voluntary movement upon the electrical activity of the precentral gyrus
    • H. Jasper and W. Penfield, "Electrocorticograms in man: Effect of voluntary movement upon the electrical activity of the precentral gyrus," Eur. Arch. Psych. Clin. Neuro., vol. 183, pp. 163-174, 1949.
    • (1949) Eur. Arch. Psych. Clin. Neuro , vol.183 , pp. 163-174
    • Jasper, H.1    Penfield, W.2
  • 30
    • 80053654930 scopus 로고    scopus 로고
    • Suppression during action observation and execution correlates with bold in dorsal premotor, inferior parietal, and SI cortices
    • D. Arnstein, F. Cui, C. Keysers, N. M. Maurits, and V. Gazzola, "Suppression during action observation and execution correlates with bold in dorsal premotor, inferior parietal, and SI cortices," J. Neurosci., vol. 31, no. 40, pp. 14243-14249, 2011.
    • (2011) J. Neurosci , vol.31 , Issue.40 , pp. 14243-14249
    • Arnstein, D.1    Cui, F.2    Keysers, C.3    Maurits, N.M.4    Gazzola, V.5
  • 32
    • 33746857682 scopus 로고    scopus 로고
    • Movement-related EEG indices of preparation in task switching and motor control
    • DOI 10.1016/j.brainres.2006.03.030, PII S0006899306007529
    • R. de Jong, T. E. Gladwin, and B. M. 't Hart, "Movement-related EEG indices of preparation in task switching and motor control," Brain Res., vol. 1105, no. 1, pp. 73-82, 2006. (Pubitemid 44175970)
    • (2006) Brain Research , vol.1105 , Issue.1 , pp. 73-82
    • De Jong, R.1    Gladwin, T.E.2    'T Hart, B.M.3
  • 33
    • 33846665353 scopus 로고    scopus 로고
    • A μ-rhythm matched filter for continuous control of a brain-computer interface
    • DOI 10.1109/TBME.2006.886661, 11
    • D. Krusienski, G. Schalk, D. McFarland, and J. Wolpaw, "Arhythm matched filter for continuous control of a brain-computer interface," IEEE Trans. Biomed. Eng., vol. 54, no. 2, pp. 273-280, Feb. 2007. (Pubitemid 46188170)
    • (2007) IEEE Transactions on Biomedical Engineering , vol.54 , Issue.2 , pp. 273-280
    • Krusienski, D.J.1    Schalk, G.2    McFarland, D.J.3    Wolpaw, J.R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.