메뉴 건너뛰기




Volumn , Issue , 2013, Pages

Estimation of membrane hydration status for standby proton exchange membrane fuel cell systems by impedance measurement: First results on variable temperature stack characterization

Author keywords

distributed power generation; electric vehicles; Fuel cells; humidity measurement; impedance measurement; uninterruptible power systems

Indexed keywords

CELL DIAGNOSTICS; COMPLEX IMPEDANCE; HUMIDITY MEASUREMENTS; IMPEDANCE MEASUREMENT; MEMBRANE HYDRATION; PROTON EXCHANGE MEMBRANE FUEL CELL SYSTEMS; RELATIVE HUMIDITY AND TEMPERATURES; VARIABLE TEMPERATURE;

EID: 84879952849     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/EVER.2013.6521593     Document Type: Conference Paper
Times cited : (2)

References (12)
  • 2
    • 0030257673 scopus 로고    scopus 로고
    • Studies on ionexchange membranes. Part 1. Effect of humidity on the conductivity of Nafion
    • A. Anantaraman and C. Gardner, "Studies on ionexchange membranes. Part 1. Effect of humidity on the conductivity of Nafion, " Journal of Electroanalytical Chemistry, vol. 414, no. 2, pp. 115-120, 1996.
    • (1996) Journal of Electroanalytical Chemistry , vol.414 , Issue.2 , pp. 115-120
    • Anantaraman, A.1    Gardner, C.2
  • 3
    • 33846253264 scopus 로고    scopus 로고
    • Exploring the effects of symmetrica1 and asymmetrica1 relative humidity on the performance of H2/air PEM fue1 cell at different temperatures
    • M. M. Saleh, T. Okajima, M. Hayase, F. Kitamura, and T. Ohsaka, "Exploring the effects of symmetrica1 and asymmetrica1 relative humidity on the performance of H2/air PEM fue1 cell at different temperatures, " Journal of Power Sources, vol. 164, no. 2, pp. 503-509, 2007.
    • (2007) Journal of Power Sources , vol.164 , Issue.2 , pp. 503-509
    • Saleh, M.M.1    Okajima, T.2    Hayase, M.3    Kitamura, F.4    Ohsaka, T.5
  • 7
    • 33750946385 scopus 로고    scopus 로고
    • Ac impedance diagnosis of a 500 W PEM fuel cell stack: Part i: Stack impedance
    • X. Yuan, J. C. Sun, M. Blanco, H. Wang, J. Zhang, and D. P. Wilkinson, "Ac impedance diagnosis of a 500 W PEM fuel cell stack: Part i: Stack impedance, " Journal of Power Sources, vol. 161, no. 2, pp. 920-928, 2006.
    • (2006) Journal of Power Sources , vol.161 , Issue.2 , pp. 920-928
    • Yuan, X.1    Sun, J.C.2    Blanco, M.3    Wang, H.4    Zhang, J.5    Wilkinson, D.P.6
  • 8
    • 33750941554 scopus 로고    scopus 로고
    • Ac impedance diagnosis of a 500 W PEM fuel cell stack: Part 11: Individual cell impedance
    • X. Yuan, J. C. Sun, H. Wang, and J. Zhang, "Ac impedance diagnosis of a 500 W PEM fuel cell stack: Part 11: Individual cell impedance, " Journal of Power Sources, vol. 161, no. 2, pp. 929-937, 2006.
    • (2006) Journal of Power Sources , vol.161 , Issue.2 , pp. 929-937
    • Yuan, X.1    Sun, J.C.2    Wang, H.3    Zhang, J.4
  • 9
    • 33744949245 scopus 로고    scopus 로고
    • An algorithm for estimation of membrane water content in PEM fue1 cells
    • H. Görgün, M. Arcak, and F. Barbir, "An algorithm for estimation of membrane water content in PEM fue1 cells, " Journal of Power Sources, vol. 157, no. 1, pp. 389-394, 2006.
    • (2006) Journal of Power Sources , vol.157 , Issue.1 , pp. 389-394
    • Görgün, H.1    Arcak, M.2    Barbir, F.3
  • 10
    • 77950956321 scopus 로고    scopus 로고
    • Sensirion, Datasheet SHT7x (SHT71, SHT75) , April
    • Sensirion, Datasheet SHT7x (SHT71, SHT75) Humidity and Temperature Sensor, April 2009.
    • (2009) Humidity and Temperature Sensor


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.