메뉴 건너뛰기




Volumn 186, Issue , 2013, Pages 315-320

Rapid quantitative immunochromatographic strip for multiple proteins test

Author keywords

Gold nanoparticle label; Immunoassay; Immunochromatographic strip; Multiplex immunoassay; Quantitative test

Indexed keywords

GOLD NANOPARTICLES; IMMUNOASSAY; IMMUNOCHROMATOGRAPHIC STRIPS; MULTIPLEX IMMUNOASSAYS; QUANTITATIVE TESTS;

EID: 84879910062     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.05.083     Document Type: Article
Times cited : (27)

References (13)
  • 2
    • 27144532845 scopus 로고    scopus 로고
    • Development of ELISA and immunochromatographic assay for the detection of gentamicin
    • DOI 10.1021/jf050484o
    • Y. Jin, J.W. Jang, C.H. Han, and M.H. Lee Development of ELISA and immunochromatographic assay for the detection of gentamicin Journal of Agricultural and Food Chemistry 53 2005 7639 7643 (Pubitemid 41499601)
    • (2005) Journal of Agricultural and Food Chemistry , vol.53 , Issue.20 , pp. 7639-7643
    • Jin, Y.1    Jang, J.-W.2    Han, C.-H.3    Lee, M.-H.4
  • 3
    • 33750630079 scopus 로고
    • A self performing chromatographic immunoassay for the qualitative determination of human chorionic gonadotrophin(HCG) in urine and serum
    • M. Beggs, M. Novotny, and S. Sampedro A self performing chromatographic immunoassay for the qualitative determination of human chorionic gonadotrophin(HCG) in urine and serum Clinical Chemistry 36 1990 1084 1085
    • (1990) Clinical Chemistry , vol.36 , pp. 1084-1085
    • Beggs, M.1    Novotny, M.2    Sampedro, S.3
  • 5
    • 0034141654 scopus 로고    scopus 로고
    • Conductimetric membrane strip immunosensor with polyaniline-bound gold colloids as signal generator
    • DOI 10.1016/S0956-5663(99)00063-9, PII S0956566399000639
    • J. Kim, J. Cho, G. Cha, C. Lee, H. Kim, and S. Paek Conductimetric membrane strip immunosensor with polyaniline-bound gold colloids as signal generator Biosensors and Bioelectronics 14 2000 907 915 (Pubitemid 30089415)
    • (2000) Biosensors and Bioelectronics , vol.14 , Issue.12 , pp. 907-915
    • Kim, J.-H.1    Cho, J.-H.2    Cha, G.S.3    Lee, C.-W.4    Kim, H.-B.5    Paek, S.-H.6
  • 6
    • 3042845915 scopus 로고    scopus 로고
    • Fabrication of a disposable biosensor for Escherichia coli O157:H7 detection
    • Z. Muhammad, and E. Alocilja Fabrication of a disposable biosensor for Escherichia coli O157:H7 detection IEEE Sensors Journal 3 2003 345 351
    • (2003) IEEE Sensors Journal , vol.3 , pp. 345-351
    • Muhammad, Z.1    Alocilja, E.2
  • 7
    • 0032938261 scopus 로고    scopus 로고
    • Disposable liposome immunosensor for theophylline combining an immunochromatographic membrane and a thick-film electrode
    • DOI 10.1016/S0003-2670(98)00711-9, PII S0003267098007119
    • K.S. Lee, T. Kim, M. Shin, W. Lee, and J. Park Disposable liposome immunosensor for theophylline combining an immunochromatographic membrane and a thick-film electrode Analytica Chimica Acta 380 1999 17 26 (Pubitemid 29017703)
    • (1999) Analytica Chimica Acta , vol.380 , Issue.1 , pp. 17-26
    • Lee, K.S.1    Kim, T.-H.2    Shin, M.-C.3    Lee, W.-Y.4    Park, J.-K.5
  • 8
    • 27744504436 scopus 로고    scopus 로고
    • Rapid, quantitative and sensitive immunochromatographic assay based on stripping voltammetric detection of a metal ion label
    • DOI 10.1039/b507682j
    • F. Lu, K.H. Wang, and Y.H. Lin Rapid quantitative and sensitive immunochromatographic assay based on stripping voltammetric detection of a metal ion label Analyst 130 2005 1513 1517 (Pubitemid 41617747)
    • (2005) Analyst , vol.130 , Issue.11 , pp. 1513-1517
    • Lu, F.1    Wang, K.H.2    Lin, Y.3
  • 9
    • 35448966139 scopus 로고    scopus 로고
    • Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip
    • DOI 10.1021/ac070691i
    • G. Liu, Y. Lin, J. Wang, H. Wu, C.M. Wai, and Y.H. Lin Disposable electrochemical immunosensor diagnosis device based on nanoparticle probe and immunochromatographic strip Analytical Chemistry 79 2007 7644 7653 (Pubitemid 47622391)
    • (2007) Analytical Chemistry , vol.79 , Issue.20 , pp. 7644-7653
    • Liu, G.1    Lin, Y.-Y.2    Wang, J.3    Wu, H.4    Wai, C.M.5    Lin, Y.6
  • 10
    • 42649119794 scopus 로고    scopus 로고
    • A nanoparticle label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen
    • Y.Y. Lin, J. Wang, G.D. Liu, H. Wu, C.M. Wai, and Y.H. Lin A nanoparticle label/immunochromatographic electrochemical biosensor for rapid and sensitive detection of prostate-specific antigen Biosensors & Bioelectronics 23 2008 1659 1665
    • (2008) Biosensors & Bioelectronics , vol.23 , pp. 1659-1665
    • Lin, Y.Y.1    Wang, J.2    Liu, G.D.3    Wu, H.4    Wai, C.M.5    Lin, Y.H.6
  • 11
    • 52149106440 scopus 로고    scopus 로고
    • Multiplex electrochemical immunoassay using gold nanoparticle probes and immunochromatographic strips
    • X. Mao, M. Baloda, A.S. Gurung, Y. Lin, and G. Liu Multiplex electrochemical immunoassay using gold nanoparticle probes and immunochromatographic strips Electrochemistry Communications 10 2008 1636 1640
    • (2008) Electrochemistry Communications , vol.10 , pp. 1636-1640
    • Mao, X.1    Baloda, M.2    Gurung, A.S.3    Lin, Y.4    Liu, G.5
  • 13
    • 84866361048 scopus 로고    scopus 로고
    • Immunochromatographic assay on thread
    • G. Zhou, X. Mao, and D. Juncker Immunochromatographic assay on thread Analytical Chemistry 84 2012 7736 7743
    • (2012) Analytical Chemistry , vol.84 , pp. 7736-7743
    • Zhou, G.1    Mao, X.2    Juncker, D.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.