메뉴 건너뛰기




Volumn 61, Issue 7, 2013, Pages 414-416

Nonanastomotic rupture of thoracic aortic Dacron graft treated by endovascular stent graft placement

Author keywords

Dacron; Rupture; Stent graft

Indexed keywords

ADULT; AORTA DISSECTING ANEURYSM; AORTA DISSECTION; AORTA GRAFT; AORTA RUPTURE; ARTERY ANASTOMOSIS; ARTICLE; CASE REPORT; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; DACRON VASCULAR PROSTHESIS; DEEP HYPOTHERMIC CIRCULATORY ARREST; END TO END ANASTOMOSIS; ENDOLEAK; FALSE ANEURYSM; GRAFT FAILURE; HUMAN; MALE; MITRAL VALVE REGURGITATION; OUTCOME ASSESSMENT; OUTPATIENT CARE; PEROPERATIVE CARE; TRICUSPID VALVE REGURGITATION; VASCULAR STENT;

EID: 84879797375     PISSN: 18636705     EISSN: 18636713     Source Type: Journal    
DOI: 10.1007/s11748-012-0158-4     Document Type: Article
Times cited : (8)

References (8)
  • 2
    • 0036891438 scopus 로고    scopus 로고
    • True aneurysm in a femoro-popliteal Dacron graft - A case report and literature review
    • 12453702 10.1016/S0967-2109(02)00064-9
    • Khaira HS, Vohra H. True aneurysm in a femoro-popliteal Dacron graft - a case report and literature review. Cardiovasc Surg. 2002;10:644-6.
    • (2002) Cardiovasc Surg , vol.10 , pp. 644-646
    • Khaira, H.S.1    Vohra, H.2
  • 4
    • 24944454159 scopus 로고    scopus 로고
    • Non-anastomotic rupture in the guideline of a Dacron thoracic aortic graft
    • 16171611 10.1016/j.jvs.2004.05.025
    • Kawata M, Morota T, Takamoto S, Kubota H, Kitahori K. Non-anastomotic rupture in the guideline of a Dacron thoracic aortic graft. J Vasc Surg. 2005;42:573.
    • (2005) J Vasc Surg , vol.42 , pp. 573
    • Kawata, M.1    Morota, T.2    Takamoto, S.3    Kubota, H.4    Kitahori, K.5
  • 5
    • 33748780399 scopus 로고    scopus 로고
    • Late-stage, nonanastomotic rupture of double-velour Dacron graft after descending aortic replacement
    • 17000311 10.1016/j.jtcvs.2006.06.007
    • Kawamura M, Ogino H, Matsuda H, Minatoya K, Sasaki H, Kitamura S. Late-stage, nonanastomotic rupture of double-velour Dacron graft after descending aortic replacement. J Thorac Cardiovasc Surg. 2006;132:961-2.
    • (2006) J Thorac Cardiovasc Surg , vol.132 , pp. 961-962
    • Kawamura, M.1    Ogino, H.2    Matsuda, H.3    Minatoya, K.4    Sasaki, H.5    Kitamura, S.6
  • 6
    • 33947499882 scopus 로고    scopus 로고
    • Repeated transluminal endovascular Inoue stent graft placement for progressive dilatation of prosthetic graft that had been repaired with Inoue stent graft placement for dilatation 23 years after extraanatomical bypass
    • 17444182 10.1007/s11748-006-0079-1
    • Anzai T, Shimizu H, Yozu R, Hashimoto S, Kuribayashi S, Inoue K. Repeated transluminal endovascular Inoue stent graft placement for progressive dilatation of prosthetic graft that had been repaired with Inoue stent graft placement for dilatation 23 years after extraanatomical bypass. Gen Thorac Cardiovasc Surg. 2007;55:76-9.
    • (2007) Gen Thorac Cardiovasc Surg , vol.55 , pp. 76-79
    • Anzai, T.1    Shimizu, H.2    Yozu, R.3    Hashimoto, S.4    Kuribayashi, S.5    Inoue, K.6
  • 7
    • 0035091488 scopus 로고    scopus 로고
    • Dacron graft aneurysm treated by endovascular stent-graft
    • 11178716 10.1007/s002700001722 1:STN:280:DC%2BD3MzjvVWnsQ%3D%3D
    • Ofer A, Nitecki S, Hoffman A, Engel A. Dacron graft aneurysm treated by endovascular stent-graft. Cardiovasc Intervent Radiol. 2001;24(1):60-4.
    • (2001) Cardiovasc Intervent Radiol , vol.24 , Issue.1 , pp. 60-64
    • Ofer, A.1    Nitecki, S.2    Hoffman, A.3    Engel, A.4
  • 8
    • 34249025208 scopus 로고    scopus 로고
    • Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair
    • 17517926 10.1148/radiol.2433051649
    • Stavropoulos SW, Charagundla SR. Imaging techniques for detection and management of endoleaks after endovascular aortic aneurysm repair. Radiology. 2007;243:641-55.
    • (2007) Radiology , vol.243 , pp. 641-655
    • Stavropoulos, S.W.1    Charagundla, S.R.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.