메뉴 건너뛰기




Volumn 28, Issue 2, 2013, Pages 505-511

A prospective randomized trial comparing stapler and laser techniques for interlobar fissure completion during pulmonary lobectomy

Author keywords

Air leaks; Laser; Pulmonary lobectomy; Thulium laser

Indexed keywords

ADULT; AGED; ALVEOLAR AIR LEAK; ARTICLE; BLEEDING; CHEST TUBE; CHYLOTHORAX; CLINICAL ARTICLE; CONTROLLED STUDY; FEMALE; FEVER; HEART ATRIUM FIBRILLATION; HOSPITALIZATION COST; HUMAN; INTERLOBULAR FISSURE; LASER; LASER SURGERY; LENGTH OF STAY; LUNG LOBECTOMY; MALE; MULTICENTER STUDY; OPEN STUDY; OPERATION DURATION; PARALLEL DESIGN; PLEURA EFFUSION; PNEUMONIA; PNEUMOTHORAX; POSTOPERATIVE COMPLICATION; PRIORITY JOURNAL; PROSPECTIVE STUDY; RANDOMIZED CONTROLLED TRIAL; RESPIRATORY DISTRESS; STAPLER; SURGICAL STAPLING; SURGICAL TECHNIQUE; THULIUM LASER; TRANSIENT ISCHEMIC ATTACK;

EID: 84879691448     PISSN: 02688921     EISSN: 1435604X     Source Type: Journal    
DOI: 10.1007/s10103-012-1097-0     Document Type: Article
Times cited : (29)

References (25)
  • 1
    • 1642534366 scopus 로고    scopus 로고
    • Efficacy and safety of topical application of human fibrinogen/thrombin- coated collagen patch (TachoComb) for treatment of air leakage after standard lobectomy
    • 14747106 10.1016/j.ejcts.2003.11.018
    • Lang G, Csekeo A, Stamatis G, Lampl L, Hagman L, Marta GM, Mueller MR, Klepetko W (2004) Efficacy and safety of topical application of human fibrinogen/thrombin-coated collagen patch (TachoComb) for treatment of air leakage after standard lobectomy. Eur J Cardiothorac Surg 25:160-166
    • (2004) Eur J Cardiothorac Surg , vol.25 , pp. 160-166
    • Lang, G.1    Csekeo, A.2    Stamatis, G.3    Lampl, L.4    Hagman, L.5    Marta, G.M.6    Mueller, M.R.7    Klepetko, W.8
  • 2
    • 33846504008 scopus 로고    scopus 로고
    • Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery: A prospective randomised trial
    • 17187983 10.1016/j.ejcts.2006.11.033
    • Anegg U, Lindenmann J, Matzi V, Smolle J, Maier A, Smolle-Juttner F (2007) Efficiency of fleece-bound sealing (TachoSil) of air leaks in lung surgery: a prospective randomised trial. Eur J Cardiothorac Surg 31:198-202
    • (2007) Eur J Cardiothorac Surg , vol.31 , pp. 198-202
    • Anegg, U.1    Lindenmann, J.2    Matzi, V.3    Smolle, J.4    Maier, A.5    Smolle-Juttner, F.6
  • 3
    • 0028887731 scopus 로고
    • How long is "prolonged air leak"?
    • 7847995 10.1016/S0003-4975(95)81040-4 1:STN:280:DyaK2M7ltVKrsQ%3D%3D
    • Adebonojo SA (1995) How long is "prolonged air leak"? Ann Thorac Surg 59:549-550
    • (1995) Ann Thorac Surg , vol.59 , pp. 549-550
    • Adebonojo, S.A.1
  • 4
  • 5
    • 33750044834 scopus 로고    scopus 로고
    • Air leaks after lobectomy increase the risk of empyema but not of cardiopulmonary complications: A case-matched analysis
    • 17035450 10.1378/chest.130.4.1150
    • Brunelli A, Xiume F, Al Refai M, Salati M, Marasco R, Sabbatini A (2006) Air leaks after lobectomy increase the risk of empyema but not of cardiopulmonary complications: a case-matched analysis. Chest 130:1150-1156
    • (2006) Chest , vol.130 , pp. 1150-1156
    • Brunelli, A.1    Xiume, F.2    Al Refai, M.3    Salati, M.4    Marasco, R.5    Sabbatini, A.6
  • 6
    • 33745189383 scopus 로고    scopus 로고
    • Patient and surgical factors influencing air leak after lung volume reduction surgery: Lessons learned from the National Emphysema Treatment Trial
    • NETT Research Group 16798215 10.1016/j.athoracsur.2006.02.050
    • DeCamp MM, Blackstone EH, Naunheim KS, Krasna MJ, Wood DE, Meli YM, McKenna RJ Jr, NETT Research Group (2006) Patient and surgical factors influencing air leak after lung volume reduction surgery: lessons learned from the National Emphysema Treatment Trial. Ann Thorac Surg 82:197-206
    • (2006) Ann Thorac Surg , vol.82 , pp. 197-206
    • Decamp, M.M.1    Blackstone, E.H.2    Naunheim, K.S.3    Krasna, M.J.4    Wood, D.E.5    Meli, Y.M.6    McKenna, Jr.R.J.7
  • 7
    • 13244251166 scopus 로고    scopus 로고
    • Estimating hospital costs attributable to prolonged air leak in pulmonary lobectomy
    • 15691691 10.1016/j.ejcts.2004.11.005
    • Varela G, Jimenez MF, Novoa N, Aranda JL (2005) Estimating hospital costs attributable to prolonged air leak in pulmonary lobectomy. Eur J Cardiothorac Surg 27:329-333
    • (2005) Eur J Cardiothorac Surg , vol.27 , pp. 329-333
    • Varela, G.1    Jimenez, M.F.2    Novoa, N.3    Aranda, J.L.4
  • 8
    • 0031747071 scopus 로고    scopus 로고
    • Prolonged air leak following radical upper lobectomy: An analysis of incidence and possible risk factors
    • 9631785 10.1378/chest.113.6.1507 1:STN:280:DyaK1c3ptlGntA%3D%3D
    • Abolhoda A, Liu D, Brooks A, Burt M (1998) Prolonged air leak following radical upper lobectomy: an analysis of incidence and possible risk factors. Chest 113:1507-1510
    • (1998) Chest , vol.113 , pp. 1507-1510
    • Abolhoda, A.1    Liu, D.2    Brooks, A.3    Burt, M.4
  • 9
    • 33846440084 scopus 로고    scopus 로고
    • The approach of fused fissures with fissureless technique decreases the incidence of persistent air leak after lobectomy
    • 17175163 10.1016/j.ejcts.2006.11.030
    • Gomez-Caro A, Calvo MJ, Lanzas JT, Chau R, Cascales P, Parrilla P (2007) The approach of fused fissures with fissureless technique decreases the incidence of persistent air leak after lobectomy. Eur J Cardiothorac Surg 31:203-208
    • (2007) Eur J Cardiothorac Surg , vol.31 , pp. 203-208
    • Gomez-Caro, A.1    Calvo, M.J.2    Lanzas, J.T.3    Chau, R.4    Cascales, P.5    Parrilla, P.6
  • 11
    • 0032906443 scopus 로고    scopus 로고
    • Experimental and clinical evaluation of a new synthetic, absorbable sealant to reduce air leaks in thoracic operations
    • 10096971 10.1016/S0022-5223(99)70296-5 1:STN:280:DyaK1M7pslWrsg%3D%3D
    • Macchiarini P, Wain J, Almy S, Dartevelle P (1999) Experimental and clinical evaluation of a new synthetic, absorbable sealant to reduce air leaks in thoracic operations. J Thorac Cardiovasc Surg 117:751-758
    • (1999) J Thorac Cardiovasc Surg , vol.117 , pp. 751-758
    • MacChiarini, P.1    Wain, J.2    Almy, S.3    Dartevelle, P.4
  • 13
    • 0022387927 scopus 로고
    • New applications of the laser in pulmonary surgery. Hemostasis and sealing of air leaks
    • 10.1016/S0003-4975(10)60346-3
    • LoCicero J, Hartz RS, Frederiksen JW, Michaelis LL (1985) New applications of the laser in pulmonary surgery. Hemostasis and sealing of air leaks. Ann Thoracic Surg 40:546-550
    • (1985) Ann Thoracic Surg , vol.40 , pp. 546-550
    • Locicero, J.1    Hartz, R.S.2    Frederiksen, J.W.3    Michaelis, L.L.4
  • 14
    • 0005332702 scopus 로고
    • Morphologic aspects of Nd:YAG laser application (wavelengths 1064 nm and 1318 nm) on lung tissue
    • Rolle A, Unsold E, Ruprecht L, Permanetter W, Frank F (1988) Morphologic aspects of Nd:YAG laser application (wavelengths 1064 nm and 1318 nm) on lung tissue. Laser Med Surg 4:10-14
    • (1988) Laser Med Surg , vol.4 , pp. 10-14
    • Rolle, A.1    Unsold, E.2    Ruprecht, L.3    Permanetter, W.4    Frank, F.5
  • 15
    • 0024145350 scopus 로고
    • Experience in noncontact Nd:YAG laser in pulmonary surgery. A pilot study
    • 10.1016/S1010-7940(88)80004-6 1:STN:280:DyaK3c7ms1OmsA%3D%3D
    • Moghissi K, Dench M, Goebells P (1988) Experience in noncontact Nd:YAG laser in pulmonary surgery. A pilot study. Eur J Cardio-Thoracic Surg 2:87-94
    • (1988) Eur J Cardio-Thoracic Surg , vol.2 , pp. 87-94
    • Moghissi, K.1    Dench, M.2    Goebells, P.3
  • 16
    • 0024493151 scopus 로고
    • Local excision of pulmonary nodular (coin) lesion with non-contact yttrium-aluminum-garnet laser
    • Moghissi K (1989) Local excision of pulmonary nodular (coin) lesion with non-contact yttrium-aluminum-garnet laser. J Thorac Cardiovasc Surg 976:147-151
    • (1989) J Thorac Cardiovasc Surg , vol.976 , pp. 147-151
    • Moghissi, K.1
  • 17
    • 0026436123 scopus 로고
    • Usefulness of Nd:YAG laser for the excision of multiple lung metastases and segmentectomy for primary lung cancer
    • 1:STN:280:DyaK387jvFGruw%3D%3D
    • Kodama K, Doi O, Higashiyama M, Yokouchi H (1992) Usefulness of Nd:YAG laser for the excision of multiple lung metastases and segmentectomy for primary lung cancer. Kyobu Keka 45:51-55
    • (1992) Kyobu Keka , vol.45 , pp. 51-55
    • Kodama, K.1    Doi, O.2    Higashiyama, M.3    Yokouchi, H.4
  • 19
    • 33646823153 scopus 로고    scopus 로고
    • Is surgery for multiple lung metastases reasonable? A total of 328 consecutive patients with multiple-laser metastasectomies with a new 1318-nm Nd:YAG laser
    • 10.1016/j.jtcvs.2005.11.053
    • Rolle A, Pereszlenhyi A, Koch R, Richard M, Baier B (2006) Is surgery for multiple lung metastases reasonable? A total of 328 consecutive patients with multiple-laser metastasectomies with a new 1318-nm Nd:YAG laser. J Thoracic Cardiovasc Surg 131:1236-1242
    • (2006) J Thoracic Cardiovasc Surg , vol.131 , pp. 1236-1242
    • Rolle, A.1    Pereszlenhyi, A.2    Koch, R.3    Richard, M.4    Baier, B.5
  • 20
    • 0030880338 scopus 로고    scopus 로고
    • A proposed anatomical classification of the pulmonary fissures
    • 9276555 1:STN:280:DyaK2svitVGksg%3D%3D
    • Craig SR, Walker WS (1997) A proposed anatomical classification of the pulmonary fissures. J R Coll Surg Edinb 42:233-234
    • (1997) J R Coll Surg Edinb , vol.42 , pp. 233-234
    • Craig, S.R.1    Walker, W.S.2
  • 22
    • 0036229710 scopus 로고    scopus 로고
    • Preoperative risk factors for prolonged air leak following lobectomy or segmentectomy for primary lung cancer
    • 12062302 10.1016/S1010-7940(02)00076-3
    • Isowa N, Hasegawa S, Bando T, Wada H (2002) Preoperative risk factors for prolonged air leak following lobectomy or segmentectomy for primary lung cancer. Eur J Cardiothorac Surg 21:951-954
    • (2002) Eur J Cardiothorac Surg , vol.21 , pp. 951-954
    • Isowa, N.1    Hasegawa, S.2    Bando, T.3    Wada, H.4
  • 23
    • 0014151571 scopus 로고
    • Pulsed laser energy in the management of multiple pulmonary metastases
    • 4964812 1:STN:280:DyaF1c%2FlsVylsw%3D%3D
    • Minton JP, Andrews NC, Jesseph JE (1967) Pulsed laser energy in the management of multiple pulmonary metastases. J Thorac Cardiovasc Surg 54:707-1325
    • (1967) J Thorac Cardiovasc Surg , vol.54 , pp. 707-1325
    • Minton, J.P.1    Andrews, N.C.2    Jesseph, J.E.3
  • 24
    • 32544431556 scopus 로고    scopus 로고
    • Laser resection technique and results of multiple lung metastasectomies using a new 1,318 nmNd:YAG laser system
    • 16444696 10.1002/lsm.20259
    • Rolle A, Pereszlenyi A, Koch R, Bis B, Baier B (2006) Laser resection technique and results of multiple lung metastasectomies using a new 1,318 nmNd:YAG laser system. Lasers Surg Med 38:26-32
    • (2006) Lasers Surg Med , vol.38 , pp. 26-32
    • Rolle, A.1    Pereszlenyi, A.2    Koch, R.3    Bis, B.4    Baier, B.5
  • 25
    • 73249127559 scopus 로고    scopus 로고
    • Air-leak management after upper lobectomy in patients with fused fissure and chronic obstructive pulmonary disease: A pilot trial comparing sealant and standard treatment
    • 19776082 10.1510/icvts.2009.202770
    • Rena O, Papalia E, Mineo TC, Massera F, Pirondini E, Turello D, Casadio C (2009) Air-leak management after upper lobectomy in patients with fused fissure and chronic obstructive pulmonary disease: a pilot trial comparing sealant and standard treatment. Interact Cardiovasc Thorac Surg 9:973-977
    • (2009) Interact Cardiovasc Thorac Surg , vol.9 , pp. 973-977
    • Rena, O.1    Papalia, E.2    Mineo, T.C.3    Massera, F.4    Pirondini, E.5    Turello, D.6    Casadio, C.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.