메뉴 건너뛰기




Volumn 8, Issue 2, 2013, Pages 166-171

Four years of EZ-IO® system in the preand in-hospital emergency setting

Author keywords

Complications; Emergency medicine; Intraosseous access; Paediatric emergencies; Success rate

Indexed keywords

ADULT; AGE; AGED; ARTICLE; AUTOANALYZER; CHILD; CLINICAL EFFECTIVENESS; CLINICAL PROTOCOL; COMPARATIVE EFFECTIVENESS; CONTROLLED CLINICAL TRIAL; CONTROLLED STUDY; EMERGENCY CARE; EXTRAVASATION; EZ 10 SYSTEM; HOSPITAL PATIENT; HUMAN; INFANT; INTRAOSSEOUS ACCESS; MAJOR CLINICAL STUDY; MEDICAL DEVICE COMPLICATION; MEDICAL PROCEDURES; MEDICAL SPECIALIST; PRESCHOOL CHILD; PRIORITY JOURNAL; PROSPECTIVE STUDY; RESIDENT; RESUSCITATION; TIBIA; TREATMENT FAILURE; TREATMENT INDICATION; UNIVERSITY HOSPITAL; VASCULAR ACCESS; VASCULAR EQUIPMENT;

EID: 84879686414     PISSN: 18951058     EISSN: 16443640     Source Type: Journal    
DOI: 10.2478/s11536-012-0125-6     Document Type: Article
Times cited : (5)

References (21)
  • 1
    • 77954762470 scopus 로고    scopus 로고
    • Comparison of two intraosseous access devices in adult patients under resuscitation in the emergency department: A prospective, randomized study
    • 20434823 10.1016/j.resuscitation.2010.03.038
    • Leidel BA, Kirchhoff C, Braunstein V, Bogner V, Biberthaler P, Kanz KG. Comparison of two intraosseous access devices in adult patients under resuscitation in the emergency department: A prospective, randomized study. Resuscitation. 2010;81(8):994-999
    • (2010) Resuscitation , vol.81 , Issue.8 , pp. 994-999
    • Leidel, B.A.1    Kirchhoff, C.2    Braunstein, V.3    Bogner, V.4    Biberthaler, P.5    Kanz, K.G.6
  • 2
    • 79960354751 scopus 로고    scopus 로고
    • Emergency intraosseous access in a helicopter emergency medical service: A retrospective study
    • 20929544 10.1186/1757-7241-18-52
    • Sunde GA, Heradstveit BE, Vikenes BH, Heltne JK. Emergency intraosseous access in a helicopter emergency medical service: a retrospective study. Scand J Trauma Resusc Emerg Med. 2010;18:52.
    • (2010) Scand J Trauma Resusc Emerg Med , vol.18 , pp. 52
    • Sunde, G.A.1    Heradstveit, B.E.2    Vikenes, B.H.3    Heltne, J.K.4
  • 3
    • 70350046951 scopus 로고    scopus 로고
    • Use of a battery-operated needle driver for intraosseous access by novice users: Skill acquisition with cadavers
    • 19643511 10.1016/j.annemergmed.2009.06.012
    • Levitan RM, Bortle CD, Snyder TA, Nitsch DA, Pisaturo JT, Butler KH. Use of a battery-operated needle driver for intraosseous access by novice users: skill acquisition with cadavers. Ann Emerg Med. 2009;54(5):692-694
    • (2009) Ann Emerg Med , vol.54 , Issue.5 , pp. 692-694
    • Levitan, R.M.1    Bortle, C.D.2    Snyder, T.A.3    Nitsch, D.A.4    Pisaturo, J.T.5    Butler, K.H.6
  • 4
    • 34047191962 scopus 로고    scopus 로고
    • Consecutive field trials using two different intraosseous devices
    • 17454802 10.1080/10903120701205851
    • Frascone RJ, Jensen JP, Kaye K, Salzman JG. Consecutive field trials using two different intraosseous devices. Prehosp Emerg Care. 2007;11(2):164-171
    • (2007) Prehosp Emerg Care , vol.11 , Issue.2 , pp. 164-171
    • Frascone, R.J.1    Jensen, J.P.2    Kaye, K.3    Salzman, J.G.4
  • 5
    • 48049103220 scopus 로고    scopus 로고
    • Comparison of two intraosseous infusion systems for adult emergency medical use
    • 18573590 10.1016/j.resuscitation.2008.04.004
    • Brenner T, Bernhard M, Helm M, Doll S, Volkl A, Ganion N, et al. Comparison of two intraosseous infusion systems for adult emergency medical use. Resuscitation. 2008;78(3):314-319
    • (2008) Resuscitation , vol.78 , Issue.3 , pp. 314-319
    • Brenner, T.1    Bernhard, M.2    Helm, M.3    Doll, S.4    Volkl, A.5    Ganion, N.6
  • 6
    • 78651246812 scopus 로고    scopus 로고
    • Part 8: Advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations
    • 20956032 10.1016/j.resuscitation.2010.08.027
    • Deakin CD, Morrison LJ, Morley PT, Callaway CW, Kerber RE, Kronick SL, et al. Part 8: Advanced life support: 2010 International Consensus on Cardiopulmonary Resuscitation and Emergency Cardiovascular Care Science with Treatment Recommendations. Resuscitation. 2010; 81Suppl 1: e93-e174
    • (2010) Resuscitation , vol.81 , Issue.SUPPL. 1
    • Deakin, C.D.1    Morrison, L.J.2    Morley, P.T.3    Callaway, C.W.4    Kerber, R.E.5    Kronick, S.L.6
  • 7
    • 78650776540 scopus 로고    scopus 로고
    • Efficacy and safety of the EZ-IO intraosseous device: Out-of-hospital implementation of a management algorithm for difficult vascular access
    • 20947238 10.1016/j.resuscitation.2010.09.008
    • Gazin N, Auger H, Jabre P, Jaulin C, Lecarpentier E, Bertrand C, et al. Efficacy and safety of the EZ-IO intraosseous device: Out-of-hospital implementation of a management algorithm for difficult vascular access. Resuscitation. 2011;82(1):126-129
    • (2011) Resuscitation , vol.82 , Issue.1 , pp. 126-129
    • Gazin, N.1    Auger, H.2    Jabre, P.3    Jaulin, C.4    Lecarpentier, E.5    Bertrand, C.6
  • 8
    • 84857049932 scopus 로고    scopus 로고
    • Use of intraosseus infusion in the German air rescue service: Nationwide analysis in the time period 2005 to 2009
    • 21881928 10.1007/s00101-011-1937-5 1:STN:280:DC%2BC38%2FnvFynsA%3D%3D
    • Helm M, Hossfeld B, Schlechtriemen T, Braun J, Lampl L, Bernhard M. [Use of intraosseus infusion in the German air rescue service: nationwide analysis in the time period 2005 to 2009]. Anaesthesist. 2011;60(12):1119-1125
    • (2011) Anaesthesist , vol.60 , Issue.12 , pp. 1119-1125
    • Helm, M.1    Hossfeld, B.2    Schlechtriemen, T.3    Braun, J.4    Lampl, L.5    Bernhard, M.6
  • 9
    • 82055179219 scopus 로고    scopus 로고
    • Der Einsatz des intraossären Zugangs im präklinischen Notarztdienst
    • 10.1007/s10049-010-1381-0
    • Kellner P, Eggers M, Rachut B. Der Einsatz des intraossären Zugangs im präklinischen Notarztdienst. Notfall Rettungsmed. 2011;14:379-388
    • (2011) Notfall Rettungsmed , vol.14 , pp. 379-388
    • Kellner, P.1    Eggers, M.2    Rachut, B.3
  • 10
    • 79952299483 scopus 로고    scopus 로고
    • Pediatric emergency patients in the air rescue service. Mission reality with special consideration to "invasive" measures
    • 20635067 10.1007/s00101-010-1759-x 1:STN:280:DC%2BC3cbhtV2qtw%3D%3D
    • Helm M, Biehn G, Lampl L, Bernhard M. [Pediatric emergency patients in the air rescue service. Mission reality with special consideration to "invasive" measures]. Anaesthesist. 2010;59(10): 896-903
    • (2010) Anaesthesist , vol.59 , Issue.10 , pp. 896-903
    • Helm, M.1    Biehn, G.2    Lampl, L.3    Bernhard, M.4
  • 11
    • 80655128257 scopus 로고    scopus 로고
    • Efficacy of the EZ-IO needle driver for out-of-hospital intraosseous access - A preliminary, observational, multicenter study
    • 22029625 10.1186/1757-7241-19-65
    • Schalk R, Schweigkofler U, Lotz G, Zacharowski K, Latasch L, Byhahn C. Efficacy of the EZ-IO needle driver for out-of-hospital intraosseous access - a preliminary, observational, multicenter study. Scand J Trauma Resusc Emerg Med. 2011;19:65
    • (2011) Scand J Trauma Resusc Emerg Med , vol.19 , pp. 65
    • Schalk, R.1    Schweigkofler, U.2    Lotz, G.3    Zacharowski, K.4    Latasch, L.5    Byhahn, C.6
  • 12
    • 80052275167 scopus 로고    scopus 로고
    • Semiautomatic intraosseous devices in pediatric prehospital care
    • 21815731 10.3109/10903127.2011.598611
    • Myers LA, Russi CS, Arteaga GM. Semiautomatic intraosseous devices in pediatric prehospital care. Prehosp Emerg Care. 2011;15(4):473-476
    • (2011) Prehosp Emerg Care , vol.15 , Issue.4 , pp. 473-476
    • Myers, L.A.1    Russi, C.S.2    Arteaga, G.M.3
  • 13
    • 83455254080 scopus 로고    scopus 로고
    • Comparison of intraosseous versus central venous vascular access in adults under resuscitation in the emergency department with inaccessible peripheral veins
    • 21893125 10.1016/j.resuscitation.2011.08.017
    • Leidel BA, Kirchhoff C, Bogner V, Braunstein V, Biberthaler P, Kanz KG. Comparison of intraosseous versus central venous vascular access in adults under resuscitation in the emergency department with inaccessible peripheral veins. Resuscitation. 2012;83(1):40-45
    • (2012) Resuscitation , vol.83 , Issue.1 , pp. 40-45
    • Leidel, B.A.1    Kirchhoff, C.2    Bogner, V.3    Braunstein, V.4    Biberthaler, P.5    Kanz, K.G.6
  • 15
    • 81555211146 scopus 로고    scopus 로고
    • Intraosseous versus intravenous vascular access during out-of-hospital cardiac arrest: A randomized controlled trial
    • 21856044 10.1016/j.annemergmed.2011.07.020
    • Reades R, Studnek JR, Vandeventer S, Garrett J. Intraosseous versus intravenous vascular access during out-of-hospital cardiac arrest: a randomized controlled trial. Ann Emerg Med. 2011;58(6):509-516
    • (2011) Ann Emerg Med , vol.58 , Issue.6 , pp. 509-516
    • Reades, R.1    Studnek, J.R.2    Vandeventer, S.3    Garrett, J.4
  • 16
    • 64949149914 scopus 로고    scopus 로고
    • Compartment syndrome following intraosseous infusion
    • 19292404 10.3928/01477447-20080801-17
    • Moen TC, Sarwark JF. Compartment syndrome following intraosseous infusion. Orthopedics. 2008;31(8):815
    • (2008) Orthopedics , vol.31 , Issue.8 , pp. 815
    • Moen, T.C.1    Sarwark, J.F.2
  • 17
    • 0028039965 scopus 로고
    • Intraosseous extravasation complication reports
    • 8304621 10.1016/S0196-0644(94)70053-2 1:STN:280:DyaK2c7js1yjtQ%3D%3D
    • Simmons CM, Johnson NE, Perkin RM, van Stralen D. Intraosseous extravasation complication reports. Ann Emerg Med. 1994;23(2):363-366
    • (1994) Ann Emerg Med , vol.23 , Issue.2 , pp. 363-366
    • Simmons, C.M.1    Johnson, N.E.2    Perkin, R.M.3    Van Stralen, D.4
  • 18
    • 0142178241 scopus 로고    scopus 로고
    • Tibial fracture as a complication of intraosseous infusion during pediatric resuscitation
    • 14566140 10.1097/01.TA.0000100170.61381.63
    • Bowley DM, Loveland J, Pitcher GJ. Tibial fracture as a complication of intraosseous infusion during pediatric resuscitation. J Trauma. 2003;55(4):786-787
    • (2003) J Trauma , vol.55 , Issue.4 , pp. 786-787
    • Bowley, D.M.1    Loveland, J.2    Pitcher, G.J.3
  • 19
    • 0025353277 scopus 로고
    • Complications of intraosseous infusion
    • 2386580 10.1016/S0196-0644(05)82504-1 1:STN:280:DyaK3c3mt1ShsA%3D%3D
    • Melker RJ, Miller G, Gearen P, Molliter L. Complications of intraosseous infusion. Ann Emerg Med. 1990;19(6):731-732
    • (1990) Ann Emerg Med , vol.19 , Issue.6 , pp. 731-732
    • Melker, R.J.1    Miller, G.2    Gearen, P.3    Molliter, L.4
  • 20
    • 45849153071 scopus 로고    scopus 로고
    • Cerebral arterial air embolism in a child after intraosseous infusion
    • 18247071 10.1007/s10140-007-0681-2
    • van Rijn RR, Knoester H, Maes A, van der Wal AC, Kubat B. Cerebral arterial air embolism in a child after intraosseous infusion. Emerg Radiol. 2008;15(4): 259-6252
    • (2008) Emerg Radiol , vol.15 , Issue.4 , pp. 259-6252
    • Van Rijn, R.R.1    Knoester, H.2    Maes, A.3    Van Der Wal, A.C.4    Kubat, B.5
  • 21
    • 0022180944 scopus 로고
    • Intraosseous infusion: An alternative route of pediatric intravascular access
    • 4025988 10.1016/S0196-0644(85)80639-9 1:STN:280:DyaL2M3nslCqsA%3D%3D
    • Rosetti VA, Thompson BM, Miller J, Mateer JR, Aprahamian C. Intraosseous infusion: an alternative route of pediatric intravascular access. Ann Emerg Med. 1985;14(9):885-888
    • (1985) Ann Emerg Med , vol.14 , Issue.9 , pp. 885-888
    • Rosetti, V.A.1    Thompson, B.M.2    Miller, J.3    Mateer, J.R.4    Aprahamian, C.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.