메뉴 건너뛰기




Volumn 139, Issue 5, 2013, Pages 502-510

Estimating discharge measurement uncertainty using the interpolated variance estimator

Author keywords

Stream gauging; Streamflow; Uncertainty

Indexed keywords

DISCHARGE (FLUID MECHANICS); ESTIMATION; STREAM FLOW; VELOCITY; WATER RESOURCES;

EID: 84879599070     PISSN: 07339429     EISSN: None     Source Type: Journal    
DOI: 10.1061/(ASCE)HY.1943-7900.0000695     Document Type: Article
Times cited : (36)

References (12)
  • 1
    • 0000486785 scopus 로고
    • Accuracy of current meter measurements
    • Carter, R. W., and Anderson, I. E. (1963). "Accuracy of current meter measurements." J. Hydraul. Div., 89(HY4), 105-115.
    • (1963) J. Hydraul. Div. , vol.89 , Issue.HY4 , pp. 105-115
    • Carter, R.W.1    Anderson, I.E.2
  • 2
    • 70350195388 scopus 로고
    • The magnitude of errors at flow measurement stations
    • Water Resources Board, Reading, UK
    • Herschy, R. (1971). "The magnitude of errors at flow measurement stations." Technical Rep., Water Resources Board, Reading, UK.
    • (1971) Technical Rep.
    • Herschy, R.1
  • 3
    • 0347026484 scopus 로고
    • The accuracy of existing and new methods of river gauging. Technical Rep.
    • Dept of Geography, Univ. of Reading, Reading, UK.
    • Herschy, R. (1975). "The accuracy of existing and new methods of river gauging." Technical Rep., Dept. of Geography, Univ. of Reading, Reading, UK.
    • (1975)
    • Herschy, R.1
  • 4
    • 85040849260 scopus 로고
    • Streamflow measurement
    • Elsevier, Essex, UK.
    • Herschy, R. (1985). Streamflow measurement, Elsevier, Essex, UK.
    • (1985)
    • Herschy, R.1
  • 5
    • 20044382164 scopus 로고    scopus 로고
    • Uncertainties in hydrometric measurements. Hydrometry
    • 2nd Ed, John Wiley, New York
    • Herschy, R. (1999). "Uncertainties in hydrometric measurements." Hydrometry, 2nd Ed., John Wiley, New York, 355-370.
    • (1999) , pp. 355-370
    • Herschy, R.1
  • 6
    • 77949327969 scopus 로고    scopus 로고
    • Hydrometry- measurement of liquid flow in open channels using current-meters or floats
    • International Standards Organization (ISO)
    • International Standards Organization (ISO). (2007a). "Hydrometry- measurement of liquid flow in open channels using current-meters or floats." ISO 748.
    • (2007) , vol.748
  • 7
    • 85172041709 scopus 로고    scopus 로고
    • Hydrometry- velocity-area method using current-meters-collection
    • International Standards Organization (ISO). and processing of data for determination of uncertainties in flow measurement ISO 1088
    • International Standards Organization (ISO). (2007b). "Hydrometry- velocity-area method using current-meters-collection and processing of data for determination of uncertainties in flow measurement." ISO 1088.
    • (2007)
  • 8
    • 77950898128 scopus 로고    scopus 로고
    • Evalulation of measurement data-Guide to the expression of uncertainty in measurement
    • (GUM 1995 with minor corrections)
    • Joint Committee for Guides in Metrology (JCGM). (2008). "Evalulation of measurement data-Guide to the expression of uncertainty in measurement." (GUM 1995 with minor corrections), 100.
    • (2008) Joint Committee for Guides in Metrology , vol.100
  • 9
    • 0024163837 scopus 로고
    • Uncertainties in the single determination of river discharge: a literature review
    • Pelletier, P. M. (1988). "Uncertainties in the single determination of river discharge: a literature review." Canadian Journal of Civil Engineering, 15(5), 834-850.
    • (1988) Canadian Journal of Civil Engineering , vol.15 , Issue.5 , pp. 834-850
    • Pelletier, P.M.1
  • 10
    • 0002194608 scopus 로고
    • Measurement and computation of streamflow
    • Volume 1. measurement of stage and discharge. 2175,US. Geological Survey, Washington, DC
    • Rantz, S., et al. (1982). "Measurement and computation of streamflow: Volume 1. measurement of stage and discharge." Water-Supply Paper 2175, U.S. Geological Survey, Washington, DC.
    • (1982) Water-Supply Paper
    • Rantz, S.1
  • 11
    • 0003606724 scopus 로고
    • Determination of error in individual discharge measurements.
    • US. Geological Survey, Norcross, GA Open-File Rep. 92-144
    • Sauer, V., and Meyer, R. (1992). "Determination of error in individual discharge measurements." Open-File Rep. 92-144, U.S. Geological Survey, Norcross, GA.
    • (1992)
    • Sauer, V.1    Meyer, R.2
  • 12
    • 84862576458 scopus 로고    scopus 로고
    • Discharge measurements at gaging stations.Techniques and Methods 3A8
    • US. Geological Survey, Reston, VA
    • Turnipseed, D. P., and Sauer, V. (2010). "Discharge measurements at gaging stations." Techniques and Methods 3A8, U.S. Geological Survey, Reston, VA.
    • (2010)
    • Turnipseed, D.P.1    Sauer, V.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.