메뉴 건너뛰기




Volumn 27, Issue 2, 2013, Pages 113-123

Parameter selection in permutation entropy for an electroencephalographic measure of isoflurane anesthetic drug effect

Author keywords

Electroencephalographic signals; Isoflurane anesthesia; Permutation entropy; Pharmacokinetic pharmacodynamic modeling; Prediction probability

Indexed keywords

COEFFICIENT OF DETERMINATION; CORRELATION COEFFICIENT; ELECTROENCEPHALOGRAPHIC SIGNALS; ISOFLURANE; PARAMETER COMBINATION; PERMUTATION ENTROPY; PHARMACODYNAMIC MODELS; PREDICTION PROBABILITIES;

EID: 84879554470     PISSN: 13871307     EISSN: 15732614     Source Type: Journal    
DOI: 10.1007/s10877-012-9419-0     Document Type: Article
Times cited : (33)

References (29)
  • 1
    • 34548039932 scopus 로고    scopus 로고
    • Using EEG to monitor anesthesia drug effects during surgery
    • 17103250 10.1007/s10877-006-9044-x
    • Jameson LC, Sloan TB. Using EEG to monitor anesthesia drug effects during surgery. J Clin Monit Comput. 2006;20:445-72.
    • (2006) J Clin Monit Comput , vol.20 , pp. 445-472
    • Jameson, L.C.1    Sloan, T.B.2
  • 2
    • 78650295590 scopus 로고    scopus 로고
    • Monitoring the depth of anaesthesia
    • 22163504 10.3390/s101210896
    • Musizza B, Ribaric S. Monitoring the depth of anaesthesia. Sensors. 2010;10:10896-935.
    • (2010) Sensors , vol.10 , pp. 10896-10935
    • Musizza, B.1    Ribaric, S.2
  • 3
    • 0031657514 scopus 로고    scopus 로고
    • A primer for EEG signal processing in anesthesia
    • 9778016 10.1097/00000542-199810000-00023 1:STN:280:DyaK1cvkvFCntA%3D%3D
    • Rampil IJ. A primer for EEG signal processing in anesthesia. Anesthesiology. 1998;89:980-1002.
    • (1998) Anesthesiology , vol.89 , pp. 980-1002
    • Rampil, I.J.1
  • 5
  • 6
    • 34548028966 scopus 로고    scopus 로고
    • Measure of the electroencephalographic effects of sevoflurane using recurrence dynamics
    • 17709191 10.1016/j.neulet.2007.07.041 1:CAS:528:DC%2BD2sXpsFantb8%3D
    • Li X, Sleigh JW, Voss LJ, Ouyang G. Measure of the electroencephalographic effects of sevoflurane using recurrence dynamics. Neurosci Lett. 2007;424:47-50.
    • (2007) Neurosci Lett , vol.424 , pp. 47-50
    • Li, X.1    Sleigh, J.W.2    Voss, L.J.3    Ouyang, G.4
  • 7
    • 52649088747 scopus 로고    scopus 로고
    • Using permutation entropy to measure the electroencephalographic effects of sevoflurane
    • 18719442 10.1097/ALN.0b013e318182a91b 1:CAS:528:DC%2BD1cXhtVWnsbfN
    • Li X, Cui S, Voss LJ. Using permutation entropy to measure the electroencephalographic effects of sevoflurane. Anesthesiology. 2008;109:448-56.
    • (2008) Anesthesiology , vol.109 , pp. 448-456
    • Li, X.1    Cui, S.2    Voss, L.J.3
  • 8
    • 78549258505 scopus 로고    scopus 로고
    • Multiscale permutation entropy analysis of EEG recordings during sevoflurane anesthesia
    • 20581428 10.1088/1741-2560/7/4/046010
    • Li D, Li X, Liang Z, Voss LJ, Sleigh JW. Multiscale permutation entropy analysis of EEG recordings during sevoflurane anesthesia. J Neural Eng. 2010;7:046010.
    • (2010) J Neural Eng , vol.7 , pp. 046010
    • Li, D.1    Li, X.2    Liang, Z.3    Voss, L.J.4    Sleigh, J.W.5
  • 9
    • 54249131184 scopus 로고    scopus 로고
    • Validation of the index of consciousness during sevoflurane and remifentanil anaesthesia: A comparison with the bispectral index and the cerebral state index
    • 18723856 10.1093/bja/aen245 1:STN:280:DC%2BD1cnlvVOhsg%3D%3D
    • Revuelta M, Paniagua P, Campos JM, Fernández JA, Martinez A, Jospin M, Litvan H. Validation of the index of consciousness during sevoflurane and remifentanil anaesthesia: a comparison with the bispectral index and the cerebral state index. Br J Anaesth. 2008;101:653-8.
    • (2008) Br J Anaesth , vol.101 , pp. 653-658
    • Revuelta, M.1    Paniagua, P.2    Campos, J.M.3    Fernández, J.A.4    Martinez, A.5    Jospin, M.6    Litvan, H.7
  • 10
    • 0342980314 scopus 로고    scopus 로고
    • Approximate entropy as an electroencephalographic measure of anesthetic drug effect during desflurane anesthesia
    • 10719951 10.1097/00000542-200003000-00016 1:CAS:528:DC%2BD3cXitVCrt78%3D
    • Bruhn J, Ropcke H, Hoeft A. Approximate entropy as an electroencephalographic measure of anesthetic drug effect during desflurane anesthesia. Anesthesiology. 2000;92:715-26.
    • (2000) Anesthesiology , vol.92 , pp. 715-726
    • Bruhn, J.1    Ropcke, H.2    Hoeft, A.3
  • 11
    • 33744971857 scopus 로고    scopus 로고
    • Comparison of entropy and complexity measures for the assessment of depth of sedation
    • 16761834 10.1109/TBME.2006.873543
    • Ferenets R, Lipping T, Anier A, Jäntti V, Melto S, Hovilehto S. Comparison of entropy and complexity measures for the assessment of depth of sedation. IEEE Trans Biomed Eng. 2006;53:1067-77.
    • (2006) IEEE Trans Biomed Eng , vol.53 , pp. 1067-1077
    • Ferenets, R.1    Lipping, T.2    Anier, A.3    Jäntti, V.4    Melto, S.5    Hovilehto, S.6
  • 12
    • 4243997063 scopus 로고    scopus 로고
    • Permutation entropy: A natural complexity measure for time series
    • 12005759 10.1103/PhysRevLett.88.174102
    • Bandt C, Pompe B. Permutation entropy: a natural complexity measure for time series. Phys Rev Lett. 2002;88:174102.
    • (2002) Phys Rev Lett , vol.88 , pp. 174102
    • Bandt, C.1    Pompe, B.2
  • 13
    • 13444273551 scopus 로고    scopus 로고
    • Ordinal time series analysis
    • 10.1016/j.ecolmodel.2004.04.003
    • Bandt C. Ordinal time series analysis. Ecol Model. 2005;182:229-38.
    • (2005) Ecol Model , vol.182 , pp. 229-238
    • Bandt, C.1
  • 14
    • 56449085745 scopus 로고    scopus 로고
    • Permutation entropy of the electroencephalogram: A measure of anaesthetic drug effect
    • 18852113 10.1093/bja/aen290 1:CAS:528:DC%2BD1cXhtl2hu7jM
    • Olofsen E, Sleigh JW, Dahan A. Permutation entropy of the electroencephalogram: a measure of anaesthetic drug effect. Br J Anaesth. 2008;101:810-21.
    • (2008) Br J Anaesth , vol.101 , pp. 810-821
    • Olofsen, E.1    Sleigh, J.W.2    Dahan, A.3
  • 15
    • 58149303225 scopus 로고    scopus 로고
    • Electroencephalographic order pattern analysis for the separation of consciousness and unconsciousness: An analysis of approximate entropy, permutation entropy, recurrence rate, and phase coupling of order recurrence plots
    • 19034098 10.1097/ALN.0b013e31818d6c55
    • Jordan D, Stockmanns G, Kochs EF, Pilge S, Schneider G. Electroencephalographic order pattern analysis for the separation of consciousness and unconsciousness: an analysis of approximate entropy, permutation entropy, recurrence rate, and phase coupling of order recurrence plots. Anesthesiology. 2008;109:1014-22.
    • (2008) Anesthesiology , vol.109 , pp. 1014-1022
    • Jordan, D.1    Stockmanns, G.2    Kochs, E.F.3    Pilge, S.4    Schneider, G.5
  • 16
    • 37649028653 scopus 로고    scopus 로고
    • Detecting dynamical changes in time series using the permutation entropy
    • 10.1103/PhysRevE.70.046217
    • Cao Y, Tung WW, Gao JB, Protopopescu VA, Hively LM. Detecting dynamical changes in time series using the permutation entropy. Phys Rev E. 2004;70:046217.
    • (2004) Phys Rev e , vol.70 , pp. 046217
    • Cao, Y.1    Tung, W.W.2    Gao, J.B.3    Protopopescu, V.A.4    Hively, L.M.5
  • 17
    • 0036897498 scopus 로고    scopus 로고
    • Changes of electroencephalographic bicoherence during isoflurane anesthesia combined with epidural anesthesia
    • 12459666 10.1097/00000542-200212000-00012 1:CAS:528:DC%2BD38XptFGms7Y%3D
    • Hagihira S, Takashina M, Mori T, Mashimo T, Yoshiya I. Changes of electroencephalographic bicoherence during isoflurane anesthesia combined with epidural anesthesia. Anesthesiology. 2002;97:1409-15.
    • (2002) Anesthesiology , vol.97 , pp. 1409-1415
    • Hagihira, S.1    Takashina, M.2    Mori, T.3    Mashimo, T.4    Yoshiya, I.5
  • 18
    • 33846040301 scopus 로고    scopus 로고
    • Removal of ocular artifacts from EEG using adaptive thresholding of wavelet coefficients
    • 17124338 10.1088/1741-2560/3/4/011 1:STN:280:DC%2BD28nos1SjtA%3D%3D
    • Krishnaveni V, Jayaraman S, Anitha L, Ramadoss K. Removal of ocular artifacts from EEG using adaptive thresholding of wavelet coefficients. J Neural Eng. 2006;3:338-46.
    • (2006) J Neural Eng , vol.3 , pp. 338-346
    • Krishnaveni, V.1    Jayaraman, S.2    Anitha, L.3    Ramadoss, K.4
  • 19
    • 29844444887 scopus 로고    scopus 로고
    • Pharmacokinetic-pharmacodynamic modeling the hypnotic effect of sevoflurane using the spectral entropy of the electroencephalogram
    • 16368811 10.1213/01.ane.0000184825.65124.24 1:CAS:528:DC%2BD2MXhtlSqurbP
    • Mckay ID, Voss LJ, Sleigh JW, Barnard JP, Johannsen EK. Pharmacokinetic-pharmacodynamic modeling the hypnotic effect of sevoflurane using the spectral entropy of the electroencephalogram. Anesth Analg. 2006;102:91-7.
    • (2006) Anesth Analg , vol.102 , pp. 91-97
    • McKay, I.D.1    Voss, L.J.2    Sleigh, J.W.3    Barnard, J.P.4    Johannsen, E.K.5
  • 20
    • 54149084130 scopus 로고    scopus 로고
    • Analysis of depth of anesthesia with Hilbert-Huang spectral entropy
    • 18812265 10.1016/j.clinph.2008.08.006
    • Li X, Li D, Liang Z, Voss LJ, Sleigh JW. Analysis of depth of anesthesia with Hilbert-Huang spectral entropy. Clin Neurophysiol. 2008;119:2465-75.
    • (2008) Clin Neurophysiol , vol.119 , pp. 2465-2475
    • Li, X.1    Li, D.2    Liang, Z.3    Voss, L.J.4    Sleigh, J.W.5
  • 21
    • 0030021080 scopus 로고    scopus 로고
    • Measuring the performance of anesthetic depth indicators
    • 8572353 10.1097/00000542-199601000-00005 1:STN:280:DyaK287lt1Wnuw%3D%3D
    • Smith WD, Dutton RC, Smith NT. Measuring the performance of anesthetic depth indicators. Anesthesiology. 1996;84:38-51.
    • (1996) Anesthesiology , vol.84 , pp. 38-51
    • Smith, W.D.1    Dutton, R.C.2    Smith, N.T.3
  • 22
    • 3042687108 scopus 로고    scopus 로고
    • Spectral entropy as an electroencephalographic measure of anesthetic drug effect: A comparison with bispectral index and processed midlatency auditory evoked response
    • 15220769 10.1097/00000542-200407000-00008 1:CAS:528:DC%2BD2cXlt1SksLw%3D
    • Vanluchene AL, Vereecke H, Thas O, Mortier EP, Shafer SL, Struys MM. Spectral entropy as an electroencephalographic measure of anesthetic drug effect: a comparison with bispectral index and processed midlatency auditory evoked response. Anesthesiology. 2004;101:34-42.
    • (2004) Anesthesiology , vol.101 , pp. 34-42
    • Vanluchene, A.L.1    Vereecke, H.2    Thas, O.3    Mortier, E.P.4    Shafer, S.L.5    Struys, M.M.6
  • 24
    • 38549125943 scopus 로고    scopus 로고
    • k), and signal-to-noise ratios of different electroencephalographic parameters during administration of desflurane, isoflurane, and sevoflurane in rats
    • 18212573 10.1097/01.anes.0000300074.04200.b1 1:CAS:528: DC%2BD1cXosFShtg%3D%3D
    • k), and signal-to-noise ratios of different electroencephalographic parameters during administration of desflurane, isoflurane, and sevoflurane in rats. Anesthesiology. 2008;108:276-85.
    • (2008) Anesthesiology , vol.108 , pp. 276-285
    • Ihmsen, H.1    Schywalsky, M.2    Plettke, R.3    Priller, M.4    Walz, F.5    Schwilden, H.6
  • 25
    • 0033779447 scopus 로고    scopus 로고
    • Electroencephalogram approximate entropy correctly classifies the occurrence of burst suppression pattern as increasing anesthetic drug effect
    • 11020750 10.1097/00000542-200010000-00018 1:CAS:528:DC%2BD3cXnsFGjsbk%3D
    • Bruhn J, Röpcke H, Rehberg B, Bouillon T, Hoeft A. Electroencephalogram approximate entropy correctly classifies the occurrence of burst suppression pattern as increasing anesthetic drug effect. Anesthesiology. 2000;93:981-5.
    • (2000) Anesthesiology , vol.93 , pp. 981-985
    • Bruhn, J.1    Röpcke, H.2    Rehberg, B.3    Bouillon, T.4    Hoeft, A.5
  • 26
    • 1642270538 scopus 로고    scopus 로고
    • Electroencephalographic bicoherence is sensitive to noxious stimuli during isoflurane or sevoflurane anesthesia
    • 15087616 10.1097/00000542-200404000-00011 1:CAS:528:DC%2BD2cXjs1ahurs%3D
    • Hagihira S, Takashina M, Mori T, Ueyama H, Mashimo T. Electroencephalographic bicoherence is sensitive to noxious stimuli during isoflurane or sevoflurane anesthesia. Anesthesiology. 2004;100:818-25.
    • (2004) Anesthesiology , vol.100 , pp. 818-825
    • Hagihira, S.1    Takashina, M.2    Mori, T.3    Ueyama, H.4    Mashimo, T.5
  • 27
    • 77956871966 scopus 로고    scopus 로고
    • The effect of skin incision on the electroencephalogram during general anesthesia maintained with propofol or desflurane
    • 20680669 10.1007/s10877-010-9251-3
    • Sleigh JW, Leslie K, Voss LJ. The effect of skin incision on the electroencephalogram during general anesthesia maintained with propofol or desflurane. J Clin Monit Comput. 2010;24:307-18.
    • (2010) J Clin Monit Comput , vol.24 , pp. 307-318
    • Sleigh, J.W.1    Leslie, K.2    Voss, L.J.3
  • 28
    • 0348019123 scopus 로고    scopus 로고
    • Does bispectral analysis of the electroencephalogram add anything but complexity?
    • 14665546 10.1093/bja/aeh003 1:STN:280:DC%2BD3srosVSrsw%3D%3D
    • Miller A, Sleigh JW, Barnard J, Steyn-Ross DA. Does bispectral analysis of the electroencephalogram add anything but complexity? Br J Anaesth. 2004;92:8-13.
    • (2004) Br J Anaesth , vol.92 , pp. 8-13
    • Miller, A.1    Sleigh, J.W.2    Barnard, J.3    Steyn-Ross, D.A.4
  • 29
    • 0034817227 scopus 로고    scopus 로고
    • Practical issues in bispectral analysis of electroencephalographic signals
    • 11574365 10.1097/00000539-200110000-00032 1:STN:280: DC%2BD3Mrisl2ktQ%3D%3D
    • Hagihira S, Takashina M, Mori T, Mashimo T, Yoshiya I. Practical issues in bispectral analysis of electroencephalographic signals. Anesth Analg. 2001;93:966-70.
    • (2001) Anesth Analg , vol.93 , pp. 966-970
    • Hagihira, S.1    Takashina, M.2    Mori, T.3    Mashimo, T.4    Yoshiya, I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.