메뉴 건너뛰기




Volumn 184, Issue , 2013, Pages 247-253

Upper extremity reachable workspace evaluation with kinect

Author keywords

Goniometry; Kinect; Reachable workspace; Upper limb evaluation

Indexed keywords

VIRTUAL REALITY;

EID: 84879512032     PISSN: 09269630     EISSN: 18798365     Source Type: Conference Proceeding    
DOI: 10.3233/978-1-61499-209-7-247     Document Type: Conference Paper
Times cited : (35)

References (8)
  • 1
    • 0347360314 scopus 로고    scopus 로고
    • Evidence-based rating of upper-extremity motor function tests used for people following a stroke
    • E. Croarkin, J. Danoff and C. Barnes, Evidence-based rating of upper-extremity motor function tests used for people following a stroke, Physical Therapy 84 (2008), 62-74.
    • (2008) Physical Therapy , vol.84 , pp. 62-74
    • Croarkin, E.1    Danoff, J.2    Barnes, C.3
  • 2
    • 77953847670 scopus 로고    scopus 로고
    • Reliability of shoulder range of motion comparing a goniometer to a digital level
    • M. Mullaney, M. McHugh, C. Johnson and T. Tyler, Reliability of shoulder range of motion comparing a goniometer to a digital level, Physiother Theory Pract 26 (2010), 327-333.
    • (2010) Physiother Theory Pract , vol.26 , pp. 327-333
    • Mullaney, M.1    McHugh, M.2    Johnson, C.3    Tyler, T.4
  • 3
    • 0023609042 scopus 로고
    • Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity
    • R. Gajdosik and R. Bohannon, Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity, Phys Ther 67 (1987), 1867-1872.
    • (1987) Phys Ther , vol.67 , pp. 1867-1872
    • Gajdosik, R.1    Bohannon, R.2
  • 4
    • 33751508772 scopus 로고    scopus 로고
    • A kinematic model of the shoulder complex to evaluate the arm-reachable workspace
    • N. Klopcar, M. Tomsic and J. Lenarcic, A kinematic model of the shoulder complex to evaluate the arm-reachable workspace, Journal of Biomechanics 40 (2007), 86-91.
    • (2007) Journal of Biomechanics , vol.40 , pp. 86-91
    • Klopcar, N.1    Tomsic, M.2    Lenarcic, J.3
  • 5
    • 84866454704 scopus 로고    scopus 로고
    • Development and application of stereo camera-based upper extremity workspace evaluation in patients with neuromuscular diseases
    • G. Kurillo, J. J. Han, R. T. Abresch, A. Nicorici, P. Yan and R. Bajcsy, Development and application of stereo camera-based upper extremity workspace evaluation in patients with neuromuscular diseases, PLoS ONE 7 (2012).
    • (2012) PLoS ONE , vol.7
    • Kurillo, G.1    Han, J.J.2    Abresch, R.T.3    Nicorici, A.4    Yan, P.5    Bajcsy, R.6
  • 6
    • 84857612141 scopus 로고    scopus 로고
    • Accuracy and resolution of Kinect depth data for indoor mapping applications
    • K. Khoshelham and S. O. Elberink, Accuracy and resolution of Kinect depth data for indoor mapping applications, Sensors 12 (2012), 1437-1454.
    • (2012) Sensors , vol.12 , pp. 1437-1454
    • Khoshelham, K.1    Elberink, S.O.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.