메뉴 건너뛰기




Volumn 50, Issue 2, 2013, Pages 147-155

Analysis of plasma 3-methoxytyramine, normetanephrine and metanephrine by ultraperformance liquid chromatography-tandem mass spectrometry: Utility for diagnosis of dopamineproducing metastatic phaeochromocytoma

Author keywords

[No Author keywords available]

Indexed keywords

3 O METHYLDOPAMINE; DOPAMINE; METADRENALIN; NORMETADRENALIN;

EID: 84879442272     PISSN: 00045632     EISSN: 17581001     Source Type: Journal    
DOI: 10.1258/acb.2012.012112     Document Type: Article
Times cited : (99)

References (24)
  • 1
    • 2442534005 scopus 로고    scopus 로고
    • Advances in metanephrine testing for the diagnosis of pheochromocytoma
    • Singh RJ. Advances in metanephrine testing for the diagnosis of pheochromocytoma. Clin Lab Med 2004;24:85-103
    • (2004) Clin Lab Med , vol.24 , pp. 85-103
    • Singh, R.J.1
  • 2
    • 0037139449 scopus 로고    scopus 로고
    • Biochemical diagnosis of pheochromocytoma - which test is best?
    • Lenders JWM, Pacak K, Walther MM, et al. Biochemical diagnosis of pheochromocytoma - which test is best? JAMA 2002;287:1427-34
    • (2002) JAMA , vol.287 , pp. 1427-1434
    • Lenders, J.W.M.1    Pacak, K.2    Walther, M.M.3
  • 3
    • 79952223410 scopus 로고    scopus 로고
    • Measurements of plasma methoxytyramine, normetanephrine, and metanephrine as discriminators of different hereditary forms of pheochromocytoma
    • Eisenhofer G, Lenders JW, Timmers H, et al. Measurements of plasma methoxytyramine, normetanephrine, and metanephrine as discriminators of different hereditary forms of pheochromocytoma. Clin Chem 2011;57:411-20
    • (2011) Clin Chem , vol.57 , pp. 411-420
    • Eisenhofer, G.1    Lenders, J.W.2    Timmers, H.3
  • 4
    • 33644822473 scopus 로고    scopus 로고
    • Clinical presentation and penetrance of pheochromocytoma/paraganglioma syndromes
    • Benn DE, Gimenez-Roqueplo AP, Reilly JR, et al. Clinical presentation and penetrance of pheochromocytoma/paraganglioma syndromes. J Clin Endocrinol Metab 2006;91:827-36
    • (2006) J Clin Endocrinol Metab , vol.91 , pp. 827-836
    • Benn, D.E.1    Gimenez-Roqueplo, A.P.2    Reilly, J.R.3
  • 5
    • 84862772345 scopus 로고    scopus 로고
    • Plasma methoxytyramine: A novel biomarker of metastatic pheochromocytoma and paraganglioma in relation to established risk factors of tumour size, location and SDHB mutation status
    • Eisenhofer G, Lenders JW, Siegert G, et al. Plasma methoxytyramine: a novel biomarker of metastatic pheochromocytoma and paraganglioma in relation to established risk factors of tumour size, location and SDHB mutation status. Eur J Cancer 2012;48:1739-49
    • (2012) Eur J Cancer , vol.48 , pp. 1739-1749
    • Eisenhofer, G.1    Lenders, J.W.2    Siegert, G.3
  • 7
    • 3242704926 scopus 로고    scopus 로고
    • Development of enantioselective immunoassays for free plasma metanephrines
    • Manz B, Kuper M, Booltink E, Fischer-Brugge U. Development of enantioselective immunoassays for free plasma metanephrines. Ann NY Acad Sci 2004;1018:582-7
    • (2004) Ann NY Acad Sci , vol.1018 , pp. 582-587
    • Manz, B.1    Kuper, M.2    Booltink, E.3    Fischer-Brugge, U.4
  • 8
    • 33745831003 scopus 로고    scopus 로고
    • Multicenter study on the diagnostic value of a new RIA for the detection of free plasma metanephrines in the work-up for pheochromocytoma
    • Lenz T, Zorner J, Kirchmaier C, et al. Multicenter study on the diagnostic value of a new RIA for the detection of free plasma metanephrines in the work-up for pheochromocytoma. Ann NY Acad Sci 2006;1073:358-73
    • (2006) Ann NY Acad Sci , vol.1073 , pp. 358-373
    • Lenz, T.1    Zorner, J.2    Kirchmaier, C.3
  • 9
    • 47349114704 scopus 로고    scopus 로고
    • Comparison of free plasma metanephrines enzyme immunoassay with I-131-MIBG scan in diagnosis of pheochromocytoma
    • Gao YC, Lu HK, Luo QY, Chen LB, Ding Y, Zhu RS. Comparison of free plasma metanephrines enzyme immunoassay with I-131-MIBG scan in diagnosis of pheochromocytoma. Clin Exp Med 2008;8:87-91
    • (2008) Clin Exp Med , vol.8 , pp. 87-91
    • Gao, Y.C.1    Lu, H.K.2    Luo, Q.Y.3    Chen, L.B.4    Ding, Y.5    Zhu, R.S.6
  • 10
    • 70350404860 scopus 로고    scopus 로고
    • The value of immunoassays for metanephrines in the biochemical diagnosis of pheochromocytomas
    • Unger N, Deutschbein T, Walz MK, Mann K, Petersenn S. The value of immunoassays for metanephrines in the biochemical diagnosis of pheochromocytomas. Horm Metab Res 2009;41:676-9
    • (2009) Horm Metab Res , vol.41 , pp. 676-679
    • Unger, N.1    Deutschbein, T.2    Walz, M.K.3    Mann, K.4    Petersenn, S.5
  • 11
    • 1542358864 scopus 로고    scopus 로고
    • Measurement of plasma free metanephrine and normetanephrine by liquid chromatographym-tandem mass spectrometry for diagnosis of pheochromocytoma
    • Lagerstedt SA, O'Kane DJ, Singh RJ. Measurement of plasma free metanephrine and normetanephrine by liquid chromatographym-tandem mass spectrometry for diagnosis of pheochromocytoma. Clin Chem 2004;50:603-11
    • (2004) Clin Chem , vol.50 , pp. 603-611
    • Lagerstedt, S.A.1    O'Kane, D.J.2    Singh, R.J.3
  • 12
    • 54049120090 scopus 로고    scopus 로고
    • Isopropanol protein precipitation for the analysis of plasma free metanephrines by liquid chromatography-tandem mass spectrometry
    • Marney LC, Laha TJ, Baird GS, Rainey PM, Hoofnagle AN. Isopropanol protein precipitation for the analysis of plasma free metanephrines by liquid chromatography-tandem mass spectrometry. Clin Chem 2008;54:1729-32
    • (2008) Clin Chem , vol.54 , pp. 1729-1732
    • Marney, L.C.1    Laha, T.J.2    Baird, G.S.3    Rainey, P.M.4    Hoofnagle, A.N.5
  • 13
    • 77649189127 scopus 로고    scopus 로고
    • Performance of plasma free metanephrines measured by liquid chromatography-tandem mass spectrometry in the diagnosis of pheochromocytoma
    • Peaston RT, Graham KS, Chambers E, van der Molen JC, Ball S. Performance of plasma free metanephrines measured by liquid chromatography-tandem mass spectrometry in the diagnosis of pheochromocytoma. Clin Chim Acta 2010;411:546-52
    • (2010) Clin Chim Acta , vol.411 , pp. 546-552
    • Peaston, R.T.1    Graham, K.S.2    Chambers, E.3    van der Molen, J.C.4    Ball, S.5
  • 14
    • 79960564457 scopus 로고    scopus 로고
    • Quantitative measurement of plasma free metanephrines by ion-pairing solid phase extraction and liquid chromatography-tandem mass spectrometry with porous graphitic carbon column
    • He X, Gabler J, Yuan C, Wang S, Shi Y, Kozak M. Quantitative measurement of plasma free metanephrines by ion-pairing solid phase extraction and liquid chromatography-tandem mass spectrometry with porous graphitic carbon column. J Chromatogr B 2011;879:2355-9
    • (2011) J Chromatogr B , vol.879 , pp. 2355-2359
    • He, X.1    Gabler, J.2    Yuan, C.3    Wang, S.4    Shi, Y.5    Kozak, M.6
  • 15
    • 79960455303 scopus 로고    scopus 로고
    • Improved plasma free metadrenaline analysis requires mixed mode cation exchange solid-phase extraction prior to liquid chromatography tandem mass spectrometry detection
    • Clarke MW, Cooke B, Hoad K, Glendenning P. Improved plasma free metadrenaline analysis requires mixed mode cation exchange solid-phase extraction prior to liquid chromatography tandem mass spectrometry detection. Ann Clin Biochem 2011;48:352-7
    • (2011) Ann Clin Biochem , vol.48 , pp. 352-357
    • Clarke, M.W.1    Cooke, B.2    Hoad, K.3    Glendenning, P.4
  • 16
    • 34548356575 scopus 로고    scopus 로고
    • Plasma free metanephrine measurement using automated online solid-phase extraction HPLC-tandem mass spectrometry
    • de Jong WH, Graham KS, van der Molen JC, et al. Plasma free metanephrine measurement using automated online solid-phase extraction HPLC-tandem mass spectrometry. Clin Chem 2007;53:1684-93
    • (2007) Clin Chem , vol.53 , pp. 1684-1693
    • de Jong, W.H.1    Graham, K.S.2    van der Molen, J.C.3
  • 17
    • 77749327332 scopus 로고    scopus 로고
    • Pilot quality assurance programme for plasma metanephrines
    • Pillai D, Callen S. Pilot quality assurance programme for plasma metanephrines. Ann Clin Biochem 2010;47:137-42
    • (2010) Ann Clin Biochem , vol.47 , pp. 137-142
    • Pillai, D.1    Callen, S.2
  • 18
    • 0036183380 scopus 로고    scopus 로고
    • Validation of liquid chromatography-tandem mass spectrometry method for analysis of urinary conjugated metanephrine and normetanephrine for screening of pheochromocytoma
    • Taylor RL, Singh RJ. Validation of liquid chromatography-tandem mass spectrometry method for analysis of urinary conjugated metanephrine and normetanephrine for screening of pheochromocytoma. Clin Chem 2002;48:533-9
    • (2002) Clin Chem , vol.48 , pp. 533-539
    • Taylor, R.L.1    Singh, R.J.2
  • 19
    • 0346158187 scopus 로고    scopus 로고
    • A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts
    • Mallet CR, Lu Z, Mazzeo JR. A study of ion suppression effects in electrospray ionization from mobile phase additives and solid-phase extracts. Rapid Commun Mass Spectrom 2004;18:49-58
    • (2004) Rapid Commun Mass Spectrom , vol.18 , pp. 49-58
    • Mallet, C.R.1    Lu, Z.2    Mazzeo, J.R.3
  • 20
    • 77953685375 scopus 로고    scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Int J Nurs Stud 2010;47:931-6
    • (2010) Int J Nurs Stud , vol.47 , pp. 931-936
    • Bland, J.M.1    Altman, D.G.2
  • 21
    • 84879449428 scopus 로고    scopus 로고
    • Reference intervals for plasma free metanephrines with an age-adjustment for normetanephrine for optimised laboratory testing of phaeochromocytoma
    • in press
    • Eisenhofer G, Lattke P, Herberg M, et al. Reference intervals for plasma free metanephrines with an age-adjustment for normetanephrine for optimised laboratory testing of phaeochromocytoma. Ann Clin Biochem 2012; in press
    • (2012) Ann Clin Biochem
    • Eisenhofer, G.1    Lattke, P.2    Herberg, M.3
  • 22
    • 33847378040 scopus 로고    scopus 로고
    • Is supine rest necessary before blood sampling for plasma metanephrines?
    • Lenders JW, Willemsen JJ, Eisenhofer G, et al. Is supine rest necessary before blood sampling for plasma metanephrines? Clin Chem 2007;53:352-4
    • (2007) Clin Chem , vol.53 , pp. 352-354
    • Lenders, J.W.1    Willemsen, J.J.2    Eisenhofer, G.3
  • 23
    • 84865024420 scopus 로고    scopus 로고
    • Rapid circulatory clearances and half-lives of plasma free metanephrines
    • Eisenhofer G, Lenders J. Rapid circulatory clearances and half-lives of plasma free metanephrines. Clin Endocrinol (Oxf) 2012;77:484-5
    • (2012) Clin Endocrinol (Oxf) , vol.77 , pp. 484-485
    • Eisenhofer, G.1    Lenders, J.2
  • 24
    • 68549101576 scopus 로고    scopus 로고
    • Dietary influences on plasma and urinary metanephrines: Implications for diagnosis of catecholamine-producing tumors
    • de Jong WH, Eisenhofer G, Post WJ, Muskiet FA, de Vries EG, Kema IP. Dietary influences on plasma and urinary metanephrines: implications for diagnosis of catecholamine-producing tumors. J Clin Endocrinol Metab 2009;94:2841-2849
    • (2009) J Clin Endocrinol Metab , vol.94 , pp. 2841-2849
    • de Jong, W.H.1    Eisenhofer, G.2    Post, W.J.3    Muskiet, F.A.4    de Vries, E.G.5    Kema, I.P.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.