Volumn 12, Issue 2, 2013, Pages 147-151

Three-dimensional visualization of endolymphatic hydrops after intravenous administration of single-dose gadodiamide

Author keywords

3D imaging; Intravenous; Magnetic resonance imaging; Me nie re's disease

Indexed keywords

CONTRAST MEDIUM; DIAGNOSTIC AGENT; GADODIAMIDE; GADOLINIUM PENTETATE;

EID: 84879408025     PISSN: 13473182     EISSN: 18802206     Source Type: Journal    
DOI: 10.2463/mrms.2012-0050     Document Type: Note
Times cited : (14)

References (12)
  • 1
    • 33947149304 scopus 로고    scopus 로고
    • Visualization of endolymphatic hydrops in patients with Meá nieà re's disease
    • Nakashima T, Naganawa S, Sugiura M, et al. Visualization of endolymphatic hydrops in patients with Meá nieà re's disease. Laryngoscope 2007; 117: 415-420.
    • (2007) Laryngoscope , vol.117 , pp. 415-420
    • Nakashima, T.1    Naganawa, S.2    Sugiura, M.3
  • 2
    • 0026360056 scopus 로고
    • Pathogenesis and pathophysiology of Meá nieà re's disease
    • Paparella MM. Pathogenesis and pathophysiology of Meá nieà re's disease. Acta Otolaryngol Suppl 1991; 485:26-35.
    • (1991) Acta Otolaryngol Suppl , vol.485 , pp. 26-35
    • Paparella, M.M.1
  • 3
    • 61649093600 scopus 로고    scopus 로고
    • 3D computerized model of endolymphatic hydrops from specimens of temporal bone
    • Teranishi M, Yoshida T, Katayama N, et al. 3D computerized model of endolymphatic hydrops from specimens of temporal bone. Acta Otolaryngol 2009; 43-47.
    • (2009) Acta Otolaryngol , pp. 43-47
    • Teranishi, M.1    Yoshida, T.2    Katayama, N.3
  • 4
    • 74049148764 scopus 로고    scopus 로고
    • Three-dimensional (3D) visualization of endolymphatic hydrops after intratympanic injection of Gd-DTPA: Optimization of a 3D-real inversion-recovery turbo spin-echo (TSE) sequence and application of a 32-channel head coil at 3T
    • Naganawa S, Ishihara S, Iwano S, Sone M, Nakashima T. Three-dimensional (3D) visualization of endolymphatic hydrops after intratympanic injection of Gd-DTPA: optimization of a 3D-real inversion-recovery turbo spin-echo (TSE) sequence and application of a 32-channel head coil at 3T. J Magn Reson Imaging 2010; 31:210-214.
    • (2010) J Magn Reson Imaging , vol.31 , pp. 210-214
    • Naganawa, S.1    Ishihara, S.2    Iwano, S.3    Sone, M.4    Nakashima, T.5
  • 5
    • 79955686765 scopus 로고    scopus 로고
    • Visualization of endolymphatic hydrops in Meá nieà re's disease with singledose intravenous gadolinium-based contrast media using heavily T2-weighted 3D-FLAIR
    • Naganawa S, Yamazaki M, Kawai H, Bokura K, Sone M, Nakashima T. Visualization of endolymphatic hydrops in Meá nieà re's disease with singledose intravenous gadolinium-based contrast media using heavily T2-weighted 3D-FLAIR. Magn Reson Med Sci 2010; 9:237-242.
    • (2010) Magn Reson Med Sci , vol.9 , pp. 237-242
    • Naganawa, S.1    Yamazaki, M.2    Kawai, H.3    Bokura, K.4    Sone, M.5    Nakashima, T.6
  • 6
    • 84863854391 scopus 로고    scopus 로고
    • Imaging of endolymphatic and perilymphatic fluid after intravenous administration of single dose gadodiamide
    • Naganawa S, Yamazaki M, Kawai H, Bokura K, Sone M, Nakashima T. Imaging of endolymphatic and perilymphatic fluid after intravenous administration of single dose gadodiamide. Magn Reson Med Sci 2012; 11:145-150.
    • (2012) Magn Reson Med Sci , vol.11 , pp. 145-150
    • Naganawa, S.1    Yamazaki, M.2    Kawai, H.3    Bokura, K.4    Sone, M.5    Nakashima, T.6
  • 7
    • 84867866320 scopus 로고    scopus 로고
    • Imaging of Meá nieà re's disease after intravenous administration of single dose gadodiamide: Utility of subtraction images with different inversion time
    • Naganawa S, Yamazaki M, Kawai H, Bokura K, Sone M, Nakashima T. Imaging of Meá nieà re's disease after intravenous administration of single dose gadodiamide: utility of subtraction images with different inversion time. Magn Reson Med Sci 2012; 11:213-219.
    • (2012) Magn Reson Med Sci , vol.11 , pp. 213-219
    • Naganawa, S.1    Yamazaki, M.2    Kawai, H.3    Bokura, K.4    Sone, M.5    Nakashima, T.6
  • 8
    • 84875623373 scopus 로고    scopus 로고
    • Imaging of Meá nieà re's disease after intravenous administration of singledose gadodiamide: Utility of multiplication of MR cisternography and HYDROPS image
    • Naganawa S, Yamazaki M, Kawai H, Bokura K, Sone M, Nakashima T. Imaging of Meá nieà re's disease after intravenous administration of singledose gadodiamide: utility of multiplication of MR cisternography and HYDROPS image. Magn Reson Med Sci 2013; 12:63-68.
    • (2013) Magn Reson Med Sci , vol.12 , pp. 63-68
    • Naganawa, S.1    Yamazaki, M.2    Kawai, H.3    Bokura, K.4    Sone, M.5    Nakashima, T.6
  • 9
    • 0029029969 scopus 로고
    • Committee on Hearing and Equilibrium guidelines for the diagnosis and evaluation of therapy in Meá nieà re's disease American Academy of Otolaryngology-Head and Neck Foundation, Inc
    • Committee on Hearing and Equilibrium guidelines for the diagnosis and evaluation of therapy in Meá nieà re's disease. American Academy of Otolaryngology-Head and Neck Foundation, Inc. Otolaryngol Head Neck Surg 1995; 113:181-185.
    • (1995) Otolaryngol Head Neck Surg , vol.113 , pp. 181-185
  • 10
    • 52049117139 scopus 로고    scopus 로고
    • Separate visualization of endolymphatic space, perilymphatic space and bone by a single pulse sequence; 3D-inversion recovery imaging utilizing real reconstruction after intratympanic Gd-DTPA administration at 3 Tesla
    • Naganawa S, Satake H, Kawamura M, Fukatsu H, Sone M, Nakashima T. Separate visualization of endolymphatic space, perilymphatic space and bone by a single pulse sequence; 3D-inversion recovery imaging utilizing real reconstruction after intratympanic Gd-DTPA administration at 3 Tesla. Eur Radiol 2008; 18:920-924.
    • (2008) Eur Radiol , vol.18 , pp. 920-924
    • Naganawa, S.1    Satake, H.2    Kawamura, M.3    Fukatsu, H.4    Sone, M.5    Nakashima, T.6
  • 11
    • 83655164452 scopus 로고    scopus 로고
    • In vivo visualization of endolyphatic hydrops in patients with Meniere's disease: Correlation with audiovestibular function
    • Gurkov R, Flatz W, Louza J, Strupp M, Krause E. In vivo visualization of endolyphatic hydrops in patients with Meniere's disease: correlation with audiovestibular function. Eur Arch Otorhinolaryngol 2011; 268:1743-1748.
    • (2011) Eur Arch Otorhinolaryngol , vol.268 , pp. 1743-1748
    • Gurkov, R.1    Flatz, W.2    Louza, J.3    Strupp, M.4    Krause, E.5
  • 12
    • 77955721834 scopus 로고    scopus 로고
    • Hypothetical mechanism for vertigo in Meá nieà re's disease
    • Gibson WP. Hypothetical mechanism for vertigo in Meá nieà re's disease. Otolaryngol Clin North Am 2010; 43:1019-1027.
    • (2010) Otolaryngol Clin North Am , vol.43 , pp. 1019-1027
    • Gibson, W.P.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.