메뉴 건너뛰기




Volumn 185, Issue , 2013, Pages 725-734

A highly stable oxygen-independent glucose biosensor based on a chitosan-albumin cryogel incorporated with carbon nanotubes and ferrocene

Author keywords

Chitosan; Cryogel; Ferrocene; Glucose biosensor; Multi walled carbon nanotubes

Indexed keywords

BIOSENSOR APPLICATIONS; CRYOGELS; FERROCENES; FLOW-INJECTION SYSTEM; GLUCOSE BIOSENSOR; GLUCOSE CONCENTRATION; MICHAELIS-MENTEN CONSTANT; OPERATIONAL STABILITY;

EID: 84879346637     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2013.05.056     Document Type: Article
Times cited : (89)

References (45)
  • 1
    • 72549102910 scopus 로고    scopus 로고
    • Poly(ethylene glycol) cryogels as potential cell scaffolds: Effect of polymerization conditions on cryogel microstructure and properties
    • Y. Hwang, C. Zhang, and S. Varghese Poly(ethylene glycol) cryogels as potential cell scaffolds: effect of polymerization conditions on cryogel microstructure and properties Journal of Materials Chemistry 20 2010 345
    • (2010) Journal of Materials Chemistry , vol.20 , pp. 345
    • Hwang, Y.1    Zhang, C.2    Varghese, S.3
  • 2
    • 78651356750 scopus 로고    scopus 로고
    • Multiwalled carbon nanotubes/cryogel composite, a new sorbent for determination of trace polycyclic aromatic hydrocarbons
    • P. Kueseng, C. Thammakhet, P. Thavarungkul, and P. Kanatharana Multiwalled carbon nanotubes/cryogel composite, a new sorbent for determination of trace polycyclic aromatic hydrocarbons Microchemical Journal 96 2010 317 323
    • (2010) Microchemical Journal , vol.96 , pp. 317-323
    • Kueseng, P.1    Thammakhet, C.2    Thavarungkul, P.3    Kanatharana, P.4
  • 3
    • 33644615883 scopus 로고    scopus 로고
    • Characterization of a novel continuous supermacroporous monolithic cryogel embedded with nanoparticles for protein chromatography
    • K. Yao, J. Yun, S. Shen, L. Wang, X. He, and X. Yu Characterization of a novel continuous supermacroporous monolithic cryogel embedded with nanoparticles for protein chromatography Journal of Chromatography 1109 2006 103 110
    • (2006) Journal of Chromatography , vol.1109 , pp. 103-110
    • Yao, K.1    Yun, J.2    Shen, S.3    Wang, L.4    He, X.5    Yu, X.6
  • 4
    • 76449108618 scopus 로고    scopus 로고
    • Electrochemical reaction of fructose dehydrogenase on carbon cryogel electrodes with controlled pore sizes
    • S. Tsujimura, A. Nishina, Y. Hamano, K. Kano, and S. Shiraishi Electrochemical reaction of fructose dehydrogenase on carbon cryogel electrodes with controlled pore sizes Electrochemistry Communications 12 2010 446 449
    • (2010) Electrochemistry Communications , vol.12 , pp. 446-449
    • Tsujimura, S.1    Nishina, A.2    Hamano, Y.3    Kano, K.4    Shiraishi, S.5
  • 5
    • 79960347768 scopus 로고    scopus 로고
    • Efficient direct electron transfer of PQQ-glucose dehydrogenase on carbon cryogel electrodes at neutral pH
    • V. Flexer, F. Durand, S. Tsujimura, and N. Mano Efficient direct electron transfer of PQQ-glucose dehydrogenase on carbon cryogel electrodes at neutral pH Analytical Chemistry 83 2011 5721 5727
    • (2011) Analytical Chemistry , vol.83 , pp. 5721-5727
    • Flexer, V.1    Durand, F.2    Tsujimura, S.3    Mano, N.4
  • 6
    • 38348999498 scopus 로고    scopus 로고
    • Monolithic macroporous albumin/chitosan cryogel structure: A new matrix for enzyme immobilization
    • M. Hedström, F. Plieva, I. Galaev, and B. Mattiasson Monolithic macroporous albumin/chitosan cryogel structure: a new matrix for enzyme immobilization Analytical and Bioanalytical Chemistry 390 2008 907 912
    • (2008) Analytical and Bioanalytical Chemistry , vol.390 , pp. 907-912
    • Hedström, M.1    Plieva, F.2    Galaev, I.3    Mattiasson, B.4
  • 7
    • 34248578162 scopus 로고    scopus 로고
    • Amperometric ethanol biosensor based on poly(vinyl alcohol)-multiwalled carbon nanotube-alcohol dehydrogenase biocomposite
    • Y.-C. Tsai, J.-D. Huang, and C.-C. Chiu Amperometric ethanol biosensor based on poly(vinyl alcohol)-multiwalled carbon nanotube-alcohol dehydrogenase biocomposite Biosensors and Bioelectronics 22 2007 3051 3056
    • (2007) Biosensors and Bioelectronics , vol.22 , pp. 3051-3056
    • Tsai, Y.-C.1    Huang, J.-D.2    Chiu, C.-C.3
  • 8
    • 48649093214 scopus 로고    scopus 로고
    • Immobilization of horseradish peroxidase on chitosan/silica sol-gel hybrid membranes for the preparation of hydrogen peroxide biosensor
    • W. Li, R. Yuan, Y. Chai, L. Zhou, S. Chen, and N. Li Immobilization of horseradish peroxidase on chitosan/silica sol-gel hybrid membranes for the preparation of hydrogen peroxide biosensor Journal of Biochemical and Biophysical Methods 70 2008 830 837
    • (2008) Journal of Biochemical and Biophysical Methods , vol.70 , pp. 830-837
    • Li, W.1    Yuan, R.2    Chai, Y.3    Zhou, L.4    Chen, S.5    Li, N.6
  • 9
    • 80755163631 scopus 로고    scopus 로고
    • Mediator-free electrochemical biosensor based on buckypaper with enhanced stability and sensitivity for glucose detection
    • A. Ahmadalinezhad, G. Wu, and A. Chen Mediator-free electrochemical biosensor based on buckypaper with enhanced stability and sensitivity for glucose detection Biosensors and Bioelectronics 2011
    • (2011) Biosensors and Bioelectronics
    • Ahmadalinezhad, A.1    Wu, G.2    Chen, A.3
  • 11
    • 33748861277 scopus 로고    scopus 로고
    • Glucose biosensor based on the layer-by-layer self-assembling of glucose oxidase and chitosan derivatives on a thiolated gold surface
    • S. Miscoria, J. Desbrieres, G. Barrera, P. Labbe, and G. Rivas Glucose biosensor based on the layer-by-layer self-assembling of glucose oxidase and chitosan derivatives on a thiolated gold surface Analytica Chimica Acta 578 2006 137 144
    • (2006) Analytica Chimica Acta , vol.578 , pp. 137-144
    • Miscoria, S.1    Desbrieres, J.2    Barrera, G.3    Labbe, P.4    Rivas, G.5
  • 12
    • 34248591288 scopus 로고    scopus 로고
    • Multilayer assembly of positively charged polyelectrolyte and negatively charged glucose oxidase on a 3D Nafion network for detecting glucose
    • X. Chen, X. Yan, K.A. Khor, and B.K. Tay Multilayer assembly of positively charged polyelectrolyte and negatively charged glucose oxidase on a 3D Nafion network for detecting glucose Biosensors and Bioelectronics 22 2007 3256 3260
    • (2007) Biosensors and Bioelectronics , vol.22 , pp. 3256-3260
    • Chen, X.1    Yan, X.2    Khor, K.A.3    Tay, B.K.4
  • 13
    • 79960449145 scopus 로고    scopus 로고
    • Evaluation of amperometric glucose biosensors based on glucose oxidase encapsulated within enzymatically synthesized polyaniline and polypyrrole
    • A. Kausaite-Minkstimiene, V. Mazeiko, A. Ramanaviciene, and A. Ramanavicius Evaluation of amperometric glucose biosensors based on glucose oxidase encapsulated within enzymatically synthesized polyaniline and polypyrrole Sensors and Actuators B: Chemical 158 2011 278 285
    • (2011) Sensors and Actuators B: Chemical , vol.158 , pp. 278-285
    • Kausaite-Minkstimiene, A.1    Mazeiko, V.2    Ramanaviciene, A.3    Ramanavicius, A.4
  • 15
    • 46549086907 scopus 로고    scopus 로고
    • A sensitive biosensor based on Os-complex mediator and glucose oxidase for low concentration glucose determination
    • L. Jiang, H. Liu, J. Liu, Q. Yang, and X. Cai A sensitive biosensor based on Os-complex mediator and glucose oxidase for low concentration glucose determination Journal of Electroanalytical Chemistry 619-620 2008 11 16
    • (2008) Journal of Electroanalytical Chemistry , vol.619-620 , pp. 11-16
    • Jiang, L.1    Liu, H.2    Liu, J.3    Yang, Q.4    Cai, X.5
  • 16
    • 19744375756 scopus 로고    scopus 로고
    • Evaluation of an amperometric glucose biosensor based on a ruthenium complex mediator of low redox potential
    • K. Yamamoto, H. Zeng, Y. Shen, M. Ahmed, and T. Kato Evaluation of an amperometric glucose biosensor based on a ruthenium complex mediator of low redox potential Talanta 66 2005 1175 1180
    • (2005) Talanta , vol.66 , pp. 1175-1180
    • Yamamoto, K.1    Zeng, H.2    Shen, Y.3    Ahmed, M.4    Kato, T.5
  • 17
    • 58149392829 scopus 로고    scopus 로고
    • Amperometric sensor based on ferrocene-modified multiwalled carbon nanotube nanocomposites as electron mediator for the determination of glucose
    • J.-D. Qiu, W.-M. Zhou, J. Guo, R. Wang, and R.-P. Liang Amperometric sensor based on ferrocene-modified multiwalled carbon nanotube nanocomposites as electron mediator for the determination of glucose Analytical Biochemistry 385 2009 264 269
    • (2009) Analytical Biochemistry , vol.385 , pp. 264-269
    • Qiu, J.-D.1    Zhou, W.-M.2    Guo, J.3    Wang, R.4    Liang, R.-P.5
  • 18
    • 80052270642 scopus 로고    scopus 로고
    • Construction of reagentless glucose biosensor based on ferrocene conjugated polypyrrole
    • M. Şenel Construction of reagentless glucose biosensor based on ferrocene conjugated polypyrrole Synthetic Metals 161 2011 1861 1868
    • (2011) Synthetic Metals , vol.161 , pp. 1861-1868
    • Şenel, M.1
  • 19
    • 34547894786 scopus 로고    scopus 로고
    • Synthesis of ferrocene-branched chitosan derivatives: Redox polysaccharides and their application to reagentless enzyme-based biosensors
    • W. Yang, H. Zhou, and C. Sun Synthesis of ferrocene-branched chitosan derivatives: redox polysaccharides and their application to reagentless enzyme-based biosensors Macromolecular Rapid Communications 28 2007 265 270
    • (2007) Macromolecular Rapid Communications , vol.28 , pp. 265-270
    • Yang, W.1    Zhou, H.2    Sun, C.3
  • 20
    • 51649122897 scopus 로고    scopus 로고
    • Amperometric sulfite sensor based on multiwalled carbon nanotubes/ferrocene-branched chitosan composites
    • H. Zhou, W. Yang, and C. Sun Amperometric sulfite sensor based on multiwalled carbon nanotubes/ferrocene-branched chitosan composites Talanta 77 2008 366 371
    • (2008) Talanta , vol.77 , pp. 366-371
    • Zhou, H.1    Yang, W.2    Sun, C.3
  • 21
    • 73449109797 scopus 로고    scopus 로고
    • Synergistic contributions of fullerene ferrocene, chitosan and ionic liquid towards improved performance for a glucose sensor
    • W. Zhilei, L. Zaijun, S. Xiulan, F. Yinjun, and L. Junkang Synergistic contributions of fullerene ferrocene, chitosan and ionic liquid towards improved performance for a glucose sensor Biosensors and Bioelectronics 25 2010 1434 1438
    • (2010) Biosensors and Bioelectronics , vol.25 , pp. 1434-1438
    • Zhilei, W.1    Zaijun, L.2    Xiulan, S.3    Yinjun, F.4    Junkang, L.5
  • 22
    • 58149392829 scopus 로고    scopus 로고
    • Amperometric sensor based on ferrocene-modified multiwalled carbon nanotube nanocomposites as electron mediator for the determination of glucose
    • J. Qiu, W. Zhou, J. Guo, R. Wang, and R. Liang Amperometric sensor based on ferrocene-modified multiwalled carbon nanotube nanocomposites as electron mediator for the determination of glucose Analytical Biochemistry 385 2009 264 269
    • (2009) Analytical Biochemistry , vol.385 , pp. 264-269
    • Qiu, J.1    Zhou, W.2    Guo, J.3    Wang, R.4    Liang, R.5
  • 23
    • 67649882498 scopus 로고    scopus 로고
    • Voltammetric sensor for glutathione determination based on ferrocene-modified carbon paste electrode
    • J.B. Raoof, R. Ojani, and M. Kolbadinezhad Voltammetric sensor for glutathione determination based on ferrocene-modified carbon paste electrode Journal of Solid State Electrochemistry 13 2008 1411 1416
    • (2008) Journal of Solid State Electrochemistry , vol.13 , pp. 1411-1416
    • Raoof, J.B.1    Ojani, R.2    Kolbadinezhad, M.3
  • 25
    • 77953494285 scopus 로고    scopus 로고
    • Glucose biosensors: An overview of use in clinical practice
    • E.H. Yoo, and S.Y. Lee Glucose biosensors: an overview of use in clinical practice Sensors 10 2010 4558 4576
    • (2010) Sensors , vol.10 , pp. 4558-4576
    • Yoo, E.H.1    Lee, S.Y.2
  • 26
    • 24644517543 scopus 로고    scopus 로고
    • Investigations of the effects of glyoxal cross-linking on the structure and properties of chitosan fiber
    • Q. Yang, F. Dou, B. Liang, and Q. Shen Investigations of the effects of glyoxal cross-linking on the structure and properties of chitosan fiber Carbohydrate Polymers 61 2005 393 398
    • (2005) Carbohydrate Polymers , vol.61 , pp. 393-398
    • Yang, Q.1    Dou, F.2    Liang, B.3    Shen, Q.4
  • 31
    • 56049122155 scopus 로고    scopus 로고
    • Ferrocene-modified multiwalled carbon nanotubes as building block for construction of reagentless enzyme-based biosensors
    • J.-D. Qiu, M.-Q. Deng, R.-P. Liang, and M. Xiong Ferrocene-modified multiwalled carbon nanotubes as building block for construction of reagentless enzyme-based biosensors Sensors and Actuators B: Chemical 135 2008 181 187
    • (2008) Sensors and Actuators B: Chemical , vol.135 , pp. 181-187
    • Qiu, J.-D.1    Deng, M.-Q.2    Liang, R.-P.3    Xiong, M.4
  • 32
    • 18044367934 scopus 로고    scopus 로고
    • Development of a carbon film electrode ferrocene, mediated glucose biosensor
    • M.E. Ghica, and C.M.A. Brett Development of a carbon film electrode ferrocene, mediated glucose biosensor Analytical Letters 38 2005 907 920
    • (2005) Analytical Letters , vol.38 , pp. 907-920
    • Ghica, M.E.1    Brett, C.M.A.2
  • 34
    • 33750478368 scopus 로고    scopus 로고
    • Association between intronic SNP in urate-anion exchanger gene, SLC22A12, and serum uric acid levels in Japanese
    • Y. Shima, K. Teruya, and H. Ohta Association between intronic SNP in urate-anion exchanger gene, SLC22A12, and serum uric acid levels in Japanese Life Sciences 79 2006 2234
    • (2006) Life Sciences , vol.79 , pp. 2234
    • Shima, Y.1    Teruya, K.2    Ohta, H.3
  • 35
    • 79956072230 scopus 로고    scopus 로고
    • Vitamin C: A concentration-function approach yields pharmacology and therapeutic discoveries
    • M. Levine, S.J. Padayatty, and M.G. Espey Vitamin C: a concentration-function approach yields pharmacology and therapeutic discoveries Advances in Nutrition 2 2011 78 88
    • (2011) Advances in Nutrition , vol.2 , pp. 78-88
    • Levine, M.1    Padayatty, S.J.2    Espey, M.G.3
  • 36
    • 77957356718 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on a triangular silver nanoprisms/chitosan composite film as immobilization matrix
    • W. Shi, and Z. Ma Amperometric glucose biosensor based on a triangular silver nanoprisms/chitosan composite film as immobilization matrix Biosensors and Bioelectronics 26 2010 1098 1103
    • (2010) Biosensors and Bioelectronics , vol.26 , pp. 1098-1103
    • Shi, W.1    Ma, Z.2
  • 37
    • 79952817809 scopus 로고    scopus 로고
    • Palladium nanoparticle/chitosan-grafted graphene nanocomposites for construction of a glucose biosensor
    • Q. Zeng, J.-S. Cheng, X.-F. Liu, H.-T. Bai, and J.-H. Jiang Palladium nanoparticle/chitosan-grafted graphene nanocomposites for construction of a glucose biosensor Biosensors and Bioelectronics 26 2011 3456 3463
    • (2011) Biosensors and Bioelectronics , vol.26 , pp. 3456-3463
    • Zeng, Q.1    Cheng, J.-S.2    Liu, X.-F.3    Bai, H.-T.4    Jiang, J.-H.5
  • 38
    • 76449114378 scopus 로고    scopus 로고
    • A new amperometric glucose biosensor based on platinum nanoparticles/polymerized ionic liquid-carbon nanotubes nanocomposites
    • X. Chu, B. Wu, C. Xiao, X. Zhang, and J. Chen A new amperometric glucose biosensor based on platinum nanoparticles/polymerized ionic liquid-carbon nanotubes nanocomposites Electrochimica Acta 55 2010 2848 2852
    • (2010) Electrochimica Acta , vol.55 , pp. 2848-2852
    • Chu, X.1    Wu, B.2    Xiao, C.3    Zhang, X.4    Chen, J.5
  • 39
    • 33847746205 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on electrodeposition of platinum nanoparticles onto covalently immobilized carbon nanotube electrode
    • X. Chu, D. Duan, G. Shen, and R. Yu Amperometric glucose biosensor based on electrodeposition of platinum nanoparticles onto covalently immobilized carbon nanotube electrode Talanta 71 2007 2040 2047
    • (2007) Talanta , vol.71 , pp. 2040-2047
    • Chu, X.1    Duan, D.2    Shen, G.3    Yu, R.4
  • 41
    • 0028410848 scopus 로고
    • Ultrafiltration of lysozyme and bovine serum albumin with polysulfone membranes modified with quaternized polyvinylimidazole
    • L. Millesime, C. Amiel, and B. Chaufer Ultrafiltration of lysozyme and bovine serum albumin with polysulfone membranes modified with quaternized polyvinylimidazole Journal of Membrane Science 89 1994 223 234
    • (1994) Journal of Membrane Science , vol.89 , pp. 223-234
    • Millesime, L.1    Amiel, C.2    Chaufer, B.3
  • 42
    • 77952322059 scopus 로고    scopus 로고
    • Chitosan-bovine serum albumin complex formation: A model to design an enzyme isolation method by polyelectrolyte precipitation
    • V. Boeris, B. Farruggia, and G. Picó Chitosan-bovine serum albumin complex formation: a model to design an enzyme isolation method by polyelectrolyte precipitation Journal of Chromatography B 878 2010 1543 1548
    • (2010) Journal of Chromatography B , vol.878 , pp. 1543-1548
    • Boeris, V.1    Farruggia, B.2    Picó, G.3
  • 43
    • 58149165037 scopus 로고    scopus 로고
    • A glucose biosensor based on Prussian blue/chitosan hybrid film
    • X. Wang, H. Gu, F. Yin, and Y. Tu A glucose biosensor based on Prussian blue/chitosan hybrid film Biosensors and Bioelectronics 24 2009 1527 1530
    • (2009) Biosensors and Bioelectronics , vol.24 , pp. 1527-1530
    • Wang, X.1    Gu, H.2    Yin, F.3    Tu, Y.4
  • 44
    • 33845462132 scopus 로고    scopus 로고
    • Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode
    • B.-Y. Wu, S.-H. Hou, F. Yin, J. Li, Z.-X. Zhao, J.-D. Huang, and Q. Chen Amperometric glucose biosensor based on layer-by-layer assembly of multilayer films composed of chitosan, gold nanoparticles and glucose oxidase modified Pt electrode Biosensors and Bioelectronics 22 2007 838 844
    • (2007) Biosensors and Bioelectronics , vol.22 , pp. 838-844
    • Wu, B.-Y.1    Hou, S.-H.2    Yin, F.3    Li, J.4    Zhao, Z.-X.5    Huang, J.-D.6    Chen, Q.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.