메뉴 건너뛰기




Volumn 61, Issue 5, 2013, Pages 382-395

MicroCT versus sTSLIM 3D Imaging of the mouse cochlea

Author keywords

Light sheet fluorescence microscopy; Micro computed tomography; Mouse cochlea; Orthogonal plane fluorescence optical sectioning microscopy; Scanning thin sheet laser imaging microscopy

Indexed keywords

ANIMAL EXPERIMENT; ANIMAL TISSUE; ARTICLE; COCHLEA; COMPARATIVE STUDY; HISTOLOGY; LASER; MICRO-COMPUTED TOMOGRAPHY; MICROSCOPY; MOUSE; NONHUMAN; OPTICS; PRIORITY JOURNAL; QUALITATIVE ANALYSIS; QUANTITATIVE ANALYSIS; SCANNING THIN SHEET LASER IMAGING MICROSCOPY; SOFT TISSUE RADIOGRAPHY; THREE DIMENSIONAL IMAGING; TISSUE FIXATION; X RAY; ANIMAL; CONFOCAL MICROSCOPY; CYTOLOGY; EQUIPMENT; METHODOLOGY; RADIOGRAPHY;

EID: 84879291620     PISSN: 00221554     EISSN: None     Source Type: Journal    
DOI: 10.1369/0022155413478613     Document Type: Article
Times cited : (34)

References (28)
  • 1
    • 84873890334 scopus 로고    scopus 로고
    • The OPFOS microscopy family: High-resolution optical sectioning of biomedical specimens
    • 2012:(Article ID 206238)1-9. doi:10.1155/2012/206238
    • Buytaert J. AN, Descamps E, Adriaens D, Dirckx JJJ. 2012. The OPFOS microscopy family: High-resolution optical sectioning of biomedical specimens. Anat Res Int. 2012:(Article ID 206238)1-9. doi:10.1155/2012/206238
    • (2012) Anat Res Int.
    • Buytaert, J.A.N.1    Descamps, E.2    Adriaens, D.3    Dirckx, J.J.J.4
  • 2
    • 34247552261 scopus 로고    scopus 로고
    • Design and quantitative resolution measurements of an optical virtual sectioning threedimensional imaging technique for biomedical specimens, featuring two-micrometer slicing resolution
    • doi:10.1117/1.2671712
    • Buytaert J. AN, Dirckx JJJ. 2007. Design and quantitative resolution measurements of an optical virtual sectioning threedimensional imaging technique for biomedical specimens, featuring two-micrometer slicing resolution. J Biomed Opt. 12(1):014039. doi:10.1117/1.2671712
    • (2007) J Biomed Opt. , vol.12 , Issue.1 , pp. 014039
    • Buytaert, J.A.N.1    Dirckx, J.J.J.2
  • 3
    • 84855716976 scopus 로고    scopus 로고
    • Realistic 3D computer model of the gerbil middle ear, featuring accurate morphology of bone and soft tissue structures
    • doi:10.1007/s10162-011-0281-4
    • Buytaert J. AN, Salih WHM, Dierick M, Jacobs P, Dirckx JJJ. 2011. Realistic 3D computer model of the gerbil middle ear, featuring accurate morphology of bone and soft tissue structures. J Assoc Res Otolaryngol. 12:681-696. doi:10.1007/s10162-011-0281-4
    • (2011) J Assoc Res Otolaryngol. , vol.12 , pp. 681-696
    • Buytaert, J.A.N.1    Salih, W.H.M.2    Dierick, M.3    Jacobs, P.4    Dirckx, J.J.J.5
  • 4
    • 84873925675 scopus 로고    scopus 로고
    • A qualitative comparison of 3D visualization in Xenopus laevis using a traditional method and a non-destructive method
    • Descamps E., Buytaert J., De Kegel B., Dirckx J., and Adriaens D. (2012). A qualitative comparison of 3D visualization in Xenopus laevis using a traditional method and a non-destructive method. Belgian J Zool. 142:99-111.
    • (2012) Belgian J Zool. , vol.142 , pp. 99-111
    • Descamps, E.1    Buytaert, J.2    de Kegel, B.3    Dirckx, J.4    Adriaens, D.5
  • 5
    • 3242715161 scopus 로고    scopus 로고
    • Octopus, a fast and user-friendly tomographic reconstruction package developed in LabView®
    • Retrieved from
    • Dierick M., Masschaele B, Hoorebeke LV. 2004. Octopus, a fast and user-friendly tomographic reconstruction package developed in LabView®. Meas Sci Tech. 15:1366-1370. Retrieved from http://iopscience.iop.org/0957-0233/15/7/020
    • (2004) Meas Sci Tech. , vol.15 , pp. 1366-1370
    • Dierick, M.1    Masschaele, B.2    Hoorebeke, L.V.3
  • 8
    • 0028209765 scopus 로고
    • Imaging the cochlea by magnetic resonance microscopy
    • doi:10.1016/0378-5955(94)90058-2
    • Henson M.M., Henson OW, Gewalt SL, Wilson JL, Johnson GA. 1994. Imaging the cochlea by magnetic resonance microscopy. Hear Res. 75:75-80. doi:10.1016/0378-5955(94)90058-2
    • (1994) Hear Res. , vol.75 , pp. 75-80
    • Henson, M.M.1    Henson, O.W.2    Gewalt, S.L.3    Wilson, J.L.4    Johnson, G.A.5
  • 9
    • 59149107083 scopus 로고    scopus 로고
    • Three-dimensional reconstruction of the guinea pig inner ear, comparison of OPFOS and light microscopy, applications of 3D reconstruction
    • doi:10.1111/j.1365-2818. 2009.03115.x
    • Hofman R., Segenhout JM, Wit HP. 2009. Three-dimensional reconstruction of the guinea pig inner ear, comparison of OPFOS and light microscopy, applications of 3D reconstruction. J Microsc. 233:251-257. doi:10.1111/j.1365-2818. 2009.03115.x
    • (2009) J Microsc. , vol.233 , pp. 251-257
    • Hofman, R.1    Segenhout, J.M.2    Wit, H.P.3
  • 10
    • 0014046125 scopus 로고
    • Some aspects of fixation with glutaraldehyde
    • Hopwood D. 1967. Some aspects of fixation with glutaraldehyde. J Anat. 101(Pt.1):83-92.
    • (1967) J Anat. , vol.101 , Issue.PART 1 , pp. 83-92
    • Hopwood, D.1
  • 11
    • 33748582307 scopus 로고    scopus 로고
    • Tissue shrinkage after fixation with formalin injection of prostatectomy specimens
    • doi:10.1007/s00428-006-0259-5
    • Jonmarker S., Valdman A, Lindberg A, Hellström M, Egevad L. 2006. Tissue shrinkage after fixation with formalin injection of prostatectomy specimens. Virchows Arch. 449:297-301. doi:10.1007/s00428-006-0259-5
    • (2006) Virchows Arch. , vol.449 , pp. 297-301
    • Jonmarker, S.1    Valdman, A.2    Lindberg, A.3    Hellström, M.4    Egevad, L.5
  • 12
    • 56449123775 scopus 로고    scopus 로고
    • Reconstruction of zebrafish early embryonic development by scanned light sheet microscopy
    • doi:10.1126/science.1162493
    • Keller P.J., Schmidt AD, Wittbrodt J, Stelzer EHK. 2008. Reconstruction of zebrafish early embryonic development by scanned light sheet microscopy. Science. 322(5904):1065-1069. doi:10.1126/science.1162493
    • (2008) Science. , vol.322 , Issue.5904 , pp. 1065-1069
    • Keller, P.J.1    Schmidt, A.D.2    Wittbrodt, J.3    Stelzer, E.H.K.4
  • 13
    • 0020663965 scopus 로고
    • Changes in dimensions of large cancellous bone specimens during histological preparation as measured on slabs from human femoral heads
    • Retrieved from
    • Lane J., Ráliš Z. 1983. Changes in dimensions of large cancellous bone specimens during histological preparation as measured on slabs from human femoral heads. Calcif Tissue Internat. 35:1-4. Retrieved from http://www.springerlink.com/ index/7120147402051661.pdf
    • (1983) Calcif Tissue Internat. , vol.35 , pp. 1-4
    • Lane, J.1    Ráliš, Z.2
  • 15
    • 77953151807 scopus 로고    scopus 로고
    • Scanning light-sheet microscopy in the whole mouse brain with HiLo background rejection
    • doi:10.1117/1.3324890
    • Mertz J., Kim J. 2011. Scanning light-sheet microscopy in the whole mouse brain with HiLo background rejection. J Biomed Opt. 15(1):016027. doi:10.1117/1.3324890
    • (2011) J Biomed Opt. , vol.15 , Issue.1 , pp. 016027
    • Mertz, J.1    Kim, J.2
  • 16
    • 61649124483 scopus 로고    scopus 로고
    • MicroCT for developmental biology: A versatile tool for high-contrast 3D imaging at histological resolutions
    • doi:10.1002/ dvdy.21857
    • Metscher BD. 2009a. MicroCT for developmental biology: a versatile tool for high-contrast 3D imaging at histological resolutions. Dev Dynamics. 238:632-640. doi:10.1002/ dvdy.21857
    • (2009) Dev Dynamics. , vol.238 , pp. 632-640
    • Metscher, B.D.1
  • 17
    • 68749106020 scopus 로고    scopus 로고
    • MicroCT for comparative morphology: Simple staining methods allow high-contrast 3D imaging of diverse non-mineralized animal tissues
    • doi:10.1186/1472-6793-9-11
    • Metscher BD. 2009b. MicroCT for comparative morphology: Simple staining methods allow high-contrast 3D imaging of diverse non-mineralized animal tissues. BMC Physiol. 9(11):1-14. doi:10.1186/1472-6793-9-11
    • (2009) BMC Physiol. , vol.9 , Issue.11 , pp. 1-14
    • Metscher, B.D.1
  • 18
    • 18444365667 scopus 로고    scopus 로고
    • Effects of dehydration mediums and temperature on total dehydration time and tissue shrinkage
    • Rown M. AB, Eed RBR, Enry RWH. 2002. Effects of dehydration mediums and temperature on total dehydration time and tissue shrinkage. J Internat Soc Plastination. 17:28-33.
    • (2002) J Internat Soc Plastination. , vol.17 , pp. 28-33
    • Rown, M.A.B.1    Eed, R.B.R.2    Enry, R.W.H.3
  • 19
    • 84857501171 scopus 로고    scopus 로고
    • Open access high-resolution 3D morphology models of cat, gerbil, rabbit, rat and human ossicular chains
    • doi:10.1016/j.heares.2011.12.004
    • Salih W. HM, Buytaert JAN, Aerts JRM, Vanderniepen P, Dierick M, Dirckx JJJ. 2012. Open access high-resolution 3D morphology models of cat, gerbil, rabbit, rat and human ossicular chains. Hear Res. 284:1-5. doi:10.1016/j.heares.2011.12.004
    • (2012) Hear Res. , vol.284 , pp. 1-5
    • Salih, W.H.M.1    Buytaert, J.A.N.2    Aerts, J.R.M.3    Vanderniepen, P.4    Dierick, M.5    Dirckx, J.J.J.6
  • 20
    • 79953778457 scopus 로고    scopus 로고
    • Light sheet fluorescence microscopy: A review
    • doi:10.1369/0022155410394857
    • Santi PA. 2011. Light sheet fluorescence microscopy: a review. J Histochem Cytochem. 59:129-138. doi:10.1369/0022155410394857
    • (2011) J Histochem Cytochem. , vol.59 , pp. 129-138
    • Santi, P.A.1
  • 23
    • 4544225743 scopus 로고    scopus 로고
    • Microwave exposure increases bone demineralization rate independent of temperature
    • doi:10.1111/j.0022-2720.2004.01382.x
    • Tinling S.P., Giberson RT, Kullar RS. 2004. Microwave exposure increases bone demineralization rate independent of temperature. J Microsc. 215(Pt 3):230-235. doi:10.1111/j.0022-2720.2004.01382.x
    • (2004) J Microsc. , vol.215 , Issue.PART 3 , pp. 230-235
    • Tinling, S.P.1    Giberson, R.T.2    Kullar, R.S.3
  • 24
    • 16344385987 scopus 로고    scopus 로고
    • Morphology of the endolymphatic sac in the guinea pig after an acute endolymphatic hydrops
    • doi:10.1016/j.heares.2004.10.010
    • Valk W.L., Wit HP, Segenhout JM, Dijk F, van der Want JJL, Albers FWJ. 2005. Morphology of the endolymphatic sac in the guinea pig after an acute endolymphatic hydrops. Hear Res. 202:180-187. doi:10.1016/j.heares.2004.10.010
    • (2005) Hear Res. , vol.202 , pp. 180-187
    • Valk, W.L.1    Wit, H.P.2    Segenhout, J.M.3    Dijk, F.4    van der Want, J.J.L.5    Albers, F.W.J.6
  • 25
    • 0036768312 scopus 로고    scopus 로고
    • Imaging the intact guinea pig tympanic bulla by orthogonal-plane fluorescence optical sectioning microscopy
    • doi:10.1016/S0378-5955(02)00493-8
    • Voie AH. 2002. Imaging the intact guinea pig tympanic bulla by orthogonal-plane fluorescence optical sectioning microscopy. Hear Res. 171:119-128. doi:10.1016/S0378-5955(02)00493-8
    • (2002) Hear Res. , vol.171 , pp. 119-128
    • Voie, A.H.1
  • 26
    • 0038353481 scopus 로고    scopus 로고
    • Corrigendum to "Imaging the intact guinea pig tympanic bulla by orthogonal plane fluorescence optical sectioning microscopy"
    • doi:10.1016/ S0378-5955(03)00167-9
    • Voie AH. 2003. Corrigendum to "Imaging the intact guinea pig tympanic bulla by orthogonal plane fluorescence optical sectioning microscopy. " Hear Res. 181:144. doi:10.1016/ S0378-5955(03)00167-9
    • (2003) Hear Res , vol.181 , pp. 144
    • Voie, A.H.1
  • 27
    • 0027270794 scopus 로고
    • Orthogonal-plane fluorescence optical sectioning: Three-dimensional imaging of macroscopic biological specimens
    • doi:10.1111/j.1365-2818.1993.tb03346.x
    • Voie AH, Burns DH, Spelman FA. 1993. Orthogonal-plane fluorescence optical sectioning: three-dimensional imaging of macroscopic biological specimens. J Microsc. 170:229-236. doi:10.1111/j.1365-2818.1993.tb03346.x
    • (1993) J Microsc. , vol.170 , pp. 229-236
    • Voie, A.H.1    Burns, D.H.2    Spelman, F.A.3
  • 28
    • 79951917264 scopus 로고    scopus 로고
    • Industrial computer tomography for dimensional metrology: Overview of influence factors and improvement strategies
    • In J. Buytaert and J. Dirckx (Eds.), Herzogenrath, Germany: Shaker Verlag
    • Welkenhuyzen F., Kiekens K, Pierlet M, Dewulf W. 2010. Industrial computer tomography for dimensional metrology: overview of influence factors and improvement strategies. In J. Buytaert and J. Dirckx (Eds.), Optical measurement techniques for systems and structures (pp. 401-410). Herzogenrath, Germany: Shaker Verlag.
    • (2010) Optical measurement techniques for systems and structures , pp. 401-410
    • Welkenhuyzen, F.1    Kiekens, K.2    Pierlet, M.3    Dewulf, W.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.