메뉴 건너뛰기




Volumn 17, Issue 6, 2013, Pages 1543-1552

The synthesis and characterization of thiol-based aryl diazonium modified glassy carbon electrode for the voltammetric determination of low levels of Hg(II)

Author keywords

Diazonium; Glassy carbon; Mercury; Surface modification; Voltammetry

Indexed keywords

DIAZONIUM; ELECTROCHEMICAL BEHAVIOUR; ELECTROCHEMICAL DETERMINATION; ELECTROLYTE SOLUTIONS; LINEAR SWEEP ANODIC STRIPPING VOLTAMMETRIES; MODIFIED GLASSY CARBON ELECTRODE; SYNTHESIS AND CHARACTERIZATIONS; VOLTAMMETRIC DETERMINATION;

EID: 84879230400     PISSN: 14328488     EISSN: None     Source Type: Journal    
DOI: 10.1007/s10008-013-2009-3     Document Type: Article
Times cited : (12)

References (46)
  • 3
    • 0000445656 scopus 로고
    • 10.1021/ac00115a029 1:CAS:528:DyaK2MXosVagsro%3D
    • Zen JM, Chung MJ (1995) Anal Chem 67:3571-3577
    • (1995) Anal Chem , vol.67 , pp. 3571-3577
    • Zen, J.M.1    Chung, M.J.2
  • 6
    • 0001442841 scopus 로고
    • 10.1038/362703b0 1:CAS:528:DyaK3sXisVKmsL8%3D
    • Turyan I, Mandler D (1993) Nature 362:703-704
    • (1993) Nature , vol.362 , pp. 703-704
    • Turyan, I.1    Mandler, D.2
  • 8
    • 0034955811 scopus 로고    scopus 로고
    • 10.1002/1521-4109(200105)13:8/9<653: AID-ELAN653>3.0.CO;2-J 1:CAS:528:DC%2BD3MXkslegurY%3D
    • Turyan I, Atiya M, Mandler D (2001) Electroanalysis 13:653-659
    • (2001) Electroanalysis , vol.13 , pp. 653-659
    • Turyan, I.1    Atiya, M.2    Mandler, D.3
  • 11
    • 0035843859 scopus 로고    scopus 로고
    • Determination of mercury in process and lagoon waters by inductively coupled plasma-mass spectrometric analysis after electrochemical preconcentration: Comparison with anodic stripping at gold and polymer coated electrodes
    • DOI 10.1016/S0003-2670(01)00838-8, PII S0003267001008388
    • Ugo P, Zampieri S, Moretto LM, Paolucci D (2001) Anal Chim Acta 434:291-300 (Pubitemid 32411542)
    • (2001) Analytica Chimica Acta , vol.434 , Issue.2 , pp. 291-300
    • Ugo, P.1    Zampieri, S.2    Moretto, L.M.3    Paolucci, D.4
  • 13
    • 0037356974 scopus 로고    scopus 로고
    • Characterization of an EDTA bonded conducting polymer modified electrode: Its application for the simultaneous determination of heavy metal ions
    • DOI 10.1021/ac0262917
    • Rahman MA, Won M-S, Shim Y-B (2003) Anal Chem 75:1123-1129 (Pubitemid 36402641)
    • (2003) Analytical Chemistry , vol.75 , Issue.5 , pp. 1123-1129
    • Rahman, Md.A.1    Won, M.-S.2    Shim, Y.-B.3
  • 18
    • 33749507536 scopus 로고    scopus 로고
    • An electroanalytical application of 2-aminothiazole-modified silica gel after adsorption and separation of Hg(II) from heavy metals in aqueous solution
    • DOI 10.1016/j.electacta.2006.06.033, PII S0013468606007031
    • Dias Filho NL, Do Carmo DR, Rosa AH (2006) Electrochim Acta 52:965-972 (Pubitemid 44528432)
    • (2006) Electrochimica Acta , vol.52 , Issue.3 , pp. 965-972
    • Filho, N.L.D.1    Carmo, D.R.D.2    Rosa, A.H.3
  • 20
    • 28444472012 scopus 로고    scopus 로고
    • Preconcentration and determination of mercury(II) at a chemically modified electrode containing 3-(2-thioimidazolyl)propyl silica gel
    • DOI 10.2116/analsci.21.1359
    • Dias NL, Do Carmo DR, Caetano L, Rosa AH (2005) Anal Sci 21:1359-1363 (Pubitemid 41738489)
    • (2005) Analytical Sciences , vol.21 , Issue.11 , pp. 1359-1363
    • Dias Filho, N.L.1    Do Carmo, D.R.2    Caetano, L.3    Rosa, A.H.4
  • 21
    • 0038136599 scopus 로고    scopus 로고
    • Voltammetric detection of lead(II) and mercury(II) using a carbon paste electrode modified with thiol self-assembled monolayer on mesoporous silica (SAMMS)
    • DOI 10.1039/b300467h
    • Yantasee W, Lin YH, Zemanian TS, Fryxell GE (2003) Analyst 128:467-472 (Pubitemid 36606185)
    • (2003) Analyst , vol.128 , Issue.5 , pp. 467-472
    • Yantasee, W.1    Lin, Y.2    Zemanian, T.S.3    Fryxell, G.E.4
  • 23
    • 28444487444 scopus 로고    scopus 로고
    • Preparation of a clay-modified carbon paste electrode based on 2-thiazoline-2-thiol-hexadecylammonium sorption for the sensitive determination of mercury
    • DOI 10.2116/analsci.21.1309
    • Filho NLD, Do Carmo DR, Gessner F, Rosa AH (2005) Anal Sci 21:1309-1316 (Pubitemid 41738483)
    • (2005) Analytical Sciences , vol.21 , Issue.11 , pp. 1309-1316
    • Dias Filho, N.L.1    Do Carmo, D.R.2    Gessner, F.3    Rosa, A.H.4
  • 24
    • 20444460390 scopus 로고    scopus 로고
    • Application of a carbon paste electrode modified with a schiff base ligand to mercury speciation in water
    • DOI 10.1002/elan.200403198
    • Colilla M, Mendiola MA, Procopio JR, Sevilla MT (2005) Electroanalysis 17:933-940 (Pubitemid 40831123)
    • (2005) Electroanalysis , vol.17 , Issue.11 , pp. 933-940
    • Colilla, M.1    Mendiola, M.A.2    Procopio, J.R.3    Sevilla, M.T.4
  • 27
    • 33746263884 scopus 로고    scopus 로고
    • Voltammetric detection of mercury and copper in seawater using a gold microwire electrode
    • DOI 10.1021/ac060231+
    • Salauen P, van den Berg CMG (2006) Anal Chem 78:5052-5060 (Pubitemid 44100641)
    • (2006) Analytical Chemistry , vol.78 , Issue.14 , pp. 5052-5060
    • Salaun, P.1    Van Den Berg, C.M.G.2
  • 28
    • 20444457625 scopus 로고    scopus 로고
    • Mercury detection in seawater using a mercaptoacetic acid modified gold microwire electrode
    • DOI 10.1002/elan.200403159
    • Widmann A, van den Berg CMG (2005) Electroanalysis 17:825-831 (Pubitemid 40831136)
    • (2005) Electroanalysis , vol.17 , Issue.10 , pp. 825-831
    • Widmann, A.1    Van Den Berg, C.M.G.2
  • 29
    • 84890005084 scopus 로고    scopus 로고
    • 2 Springer Berlin 10.1007/978-3-642-02915-8 (Pages: 215, 273-274, 286-288)
    • Scholz F (2010) Electroanalytical methods, 2nd edn. Springer, Berlin, (Pages: 215, 273-274, 286-288)
    • (2010) Electroanalytical Methods
    • Scholz, F.1
  • 31
    • 20444507770 scopus 로고    scopus 로고
    • Anodic stripping voltammetric determination of mercury using multi-walled carbon nanotubes film coated glassy carbon electrode
    • DOI 10.1007/s00216-003-2136-2
    • Yi HC (2003) Anal Bioanal Chem 377:770-774 (Pubitemid 40890296)
    • (2003) Analytical and Bioanalytical Chemistry , vol.377 , Issue.4 , pp. 770-774
    • Yi, H.1
  • 33
    • 46949111307 scopus 로고    scopus 로고
    • 10.1002/elan.200704124 1:CAS:528:DC%2BD1cXkvVymtbw%3D
    • Gooding JJ (2008) Electroanalysis 20:573-582
    • (2008) Electroanalysis , vol.20 , pp. 573-582
    • Gooding, J.J.1
  • 35
    • 33846528975 scopus 로고    scopus 로고
    • Diazonium salts: Stable monolayers on gold electrodes for sensing applications
    • DOI 10.1016/j.jelechem.2006.09.012, PII S0022072806005468
    • Liu G, Bocking T, Gooding JJ (2007) J Electroanal Chem 600:335-344 (Pubitemid 46151712)
    • (2007) Journal of Electroanalytical Chemistry , vol.600 , Issue.2 , pp. 335-344
    • Liu, G.1    Bocking, T.2    Gooding, J.J.3
  • 36
    • 78650256362 scopus 로고    scopus 로고
    • 10.1016/j.jelechem.2010.02.026 1:CAS:528:DC%2BC3cXhtlygsrvK
    • Fink L, Mandler D (2010) J Electroanal Chem 649:153-158
    • (2010) J Electroanal Chem , vol.649 , pp. 153-158
    • Fink, L.1    Mandler, D.2
  • 40
    • 0033658749 scopus 로고    scopus 로고
    • 10.1002/1521-4109(200010)12:14<1085: AID-ELAN1085>3.0.CO;2-A 1:CAS:528:DC%2BD3cXnsVSltbY%3D
    • Downard AJ (2000) Electroanalysis 12:1085-1096
    • (2000) Electroanalysis , vol.12 , pp. 1085-1096
    • Downard, A.J.1
  • 42
    • 2942746773 scopus 로고    scopus 로고
    • 10.1021/la049616i 1:CAS:528:DC%2BD2cXjvVCktro%3D
    • Brooksby PA, Downard AJ (2004) Langmuir 20:5038-5045
    • (2004) Langmuir , vol.20 , pp. 5038-5045
    • Brooksby, P.A.1    Downard, A.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.