메뉴 건너뛰기




Volumn 2, Issue 4, 2012, Pages 417-426

An electrochemical immunosensor for detection of Staphylococcus aureus bacteria based on immobilization of antibodies on self-assembled monolayers-functionalized gold electrode

Author keywords

Cyclic voltammetry; Electrochemical impedance spectroscopy; Immunosensor; Self assembled monolayer; Staphylococcus aureus

Indexed keywords

ANTIBODIES; CHEMICAL DETECTION; CHEMICAL WARFARE; ELECTROCHEMICAL BIOSENSORS; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; ELECTRON AFFINITY; GOLD; IMMUNOSENSORS; SELF ASSEMBLED MONOLAYERS;

EID: 84879193242     PISSN: None     EISSN: 20796374     Source Type: Journal    
DOI: 10.3390/bios2040417     Document Type: Article
Times cited : (87)

References (16)
  • 1
    • 0347013998 scopus 로고
    • Toxi-infections alimentaires d'origine staphylococcique
    • Chaubeau-Duffour, C. Toxi-infections alimentaires d'origine staphylococcique. Le Point Vétérinaire 1992, 24, 33-40.
    • (1992) Le Point Vétérinaire , vol.24 , pp. 33-40
    • Chaubeau-Duffour, C.1
  • 2
    • 33947139115 scopus 로고
    • Mammites à staphylocoques et sécurité alimentaire
    • De Buyser, M.-L., Lapeyre, C. Mammites à staphylocoques et sécurité alimentaire. Le Point Vétérinaire 1994, 26, 79-82.
    • (1994) Le Point Vétérinaire , vol.26 , pp. 79-82
    • De Buyser, M.-L.1    Lapeyre, C.2
  • 5
    • 78651466761 scopus 로고    scopus 로고
    • Label-free capacitive immunosensor based on quartz crystal Au electrode for rapid and sensitive detection of Escherichia coli O157:H7
    • Li, D., Feng, Y., Zhou, L., Ye, Z., Wang, J., Ying, Y., Ruan, C., Wang, R., Li, Y. Label-free capacitive immunosensor based on quartz crystal Au electrode for rapid and sensitive detection of Escherichia coli O157:H7. Anal. Chim. Acta. 2011, 687, 89-96.
    • (2011) Anal. Chim. Acta. , vol.687 , pp. 89-96
    • Li, D.1    Feng, Y.2    Zhou, L.3    Ye, Z.4    Wang, J.5    Ying, Y.6    Ruan, C.7    Wang, R.8    Li, Y.9
  • 6
    • 29144528944 scopus 로고    scopus 로고
    • A mixed self-assembled monolayer-based surface plasmonimmunosensor for detection of E. coli O157:H7
    • Subramanian, A., Irudayaraj, J., Ryan, T. A mixed self-assembled monolayer-based surface plasmonimmunosensor for detection of E. coli O157:H7. Biosens. Bioelectron. 2006, 7, 998-1006.
    • (2006) Biosens. Bioelectron. , vol.7 , pp. 998-1006
    • Subramanian, A.1    Irudayaraj, J.2    Ryan, T.3
  • 7
    • 54749134679 scopus 로고    scopus 로고
    • Detection of Escherichia coli and Salmonella typhimurium using interdigitated microelectrode capacitive immunosensors: The importance of transducer geometry
    • Laczka, O., Baldrich, E., Mu o, F.X., del Campo, F. Detection of Escherichia coli and Salmonella typhimurium using interdigitated microelectrode capacitive immunosensors: The importance of transducer geometry. J. Anal. Chem. 2008, 80, 7239-7247.
    • (2008) J. Anal. Chem. , vol.80 , pp. 7239-7247
    • Laczka, O.1    Baldrich, E.2    Muo, F.X.3    Del Campo, F.4
  • 8
    • 62649102712 scopus 로고    scopus 로고
    • Detection of Salmonella typhimurium using an electrochemical immunosensor
    • Salam, F., Tothill, I.E. Detection of Salmonella typhimurium using an electrochemical immunosensor. Biosens. Bioelectron. 2009, 24, 2630-2636.
    • (2009) Biosens. Bioelectron. , vol.24 , pp. 2630-2636
    • Salam, F.1    Tothill, I.E.2
  • 9
    • 33244495054 scopus 로고    scopus 로고
    • Mono and dithiol surfaces on surface plasmon resonance biosensors for detection of Staphylococcus aureus
    • Subramanian, A., Irudayaraj, J., Ryan, T. Mono and dithiol surfaces on surface plasmon resonance biosensors for detection of Staphylococcus aureus. Sens. Actuator. B 2006, 114, 192-198.
    • (2006) Sens. Actuator. B , vol.114 , pp. 192-198
    • Subramanian, A.1    Irudayaraj, J.2    Ryan, T.3
  • 11
    • 80052326253 scopus 로고    scopus 로고
    • A PDMS microfluidic impedance immunosensor for E. coli O157:H7 and Staphylococcus aureus detection via antibody-immobilized nanoporous membrane
    • Tan, F., Leung, P.H.M., Liu, Z.B., Zhang, Y., Xiao, L.D., Ye, W.W., Zhang, X., Yi, L., Yang, M. A PDMS microfluidic impedance immunosensor for E. coli O157:H7 and Staphylococcus aureus detection via antibody-immobilized nanoporous membrane. Sens. Actuator. B 2011, 159, 328-335.
    • (2011) Sens. Actuator. B , vol.159 , pp. 328-335
    • Tan, F.1    Leung, P.H.M.2    Liu, Z.B.3    Zhang, Y.4    Xiao, L.D.5    Ye, W.W.6    Zhang, X.7    Yi, L.8    Yang, M.9
  • 12
    • 80055067356 scopus 로고    scopus 로고
    • Electrochemical Impedance Spectroscopy (EIS) of ion sensors: Direct modeling and inverse problem solving using the Nernst-Planck-Poisson (NPP) model and the HGS(FP) optimization strategy
    • Grysakowski, B., Jasielec, J., Wierzba, B., Sokalski, T., Lewenstam, A., Danielewski, M. Electrochemical Impedance Spectroscopy (EIS) of ion sensors: Direct modeling and inverse problem solving using the Nernst-Planck-Poisson (NPP) model and the HGS(FP) optimization strategy. J. Electroanal. Chem. 2011, 662, 143-149.
    • (2011) J. Electroanal. Chem. , vol.662 , pp. 143-149
    • Grysakowski, B.1    Jasielec, J.2    Wierzba, B.3    Sokalski, T.4    Lewenstam, A.5    Danielewski, M.6
  • 13
    • 77950802398 scopus 로고    scopus 로고
    • Impedimetricimmunosensors-A review
    • Prodromidis, M.I. Impedimetricimmunosensors-A review. Electrochim. Acta 2010, 55, 4227-4223.
    • (2010) Electrochim. Acta , vol.55 , pp. 4223-4227
    • Prodromidis, M.I.1
  • 14
    • 25044431905 scopus 로고
    • Self-assembled monolayers on gold generated from Alkanethiols with the structure RNHCOCH2SH
    • Tamchang, S.W., Biebuyck, H.A., Whitesides, G.M., Jeon, N., Nuzzo, R.G. Self-assembled monolayers on gold generated from Alkanethiols with the structure RNHCOCH2SH. Langmuir 1995, 11, 4371-4382.
    • (1995) Langmuir , vol.11 , pp. 4371-4382
    • Tamchang, S.W.1    Biebuyck, H.A.2    Whitesides, G.M.3    Jeon, N.4    Nuzzo, R.G.5
  • 15
    • 74249098419 scopus 로고    scopus 로고
    • Esterification of self-assembled carboxylic-acid-terminated thiol monolayers in acid environment: A time-dependent study
    • Myrskog, A., Anderson, H., Aastrup, T., Ingemarsson, B., Liedberg, B. Esterification of self-assembled carboxylic-acid-terminated thiol monolayers in acid environment: A time-dependent study. Langmuir 2010, 26, 821-829.
    • (2010) Langmuir , vol.26 , pp. 821-829
    • Myrskog, A.1    Anderson, H.2    Aastrup, T.3    Ingemarsson, B.4    Liedberg, B.5
  • 16
    • 3142726971 scopus 로고    scopus 로고
    • Dielectric spectroscopy in a micromachined flow cytometer: Theoretical and practical considerations
    • Gawad, S., Cheung, K., Seger, U., Bertsch, A., Renaud, P. Dielectric spectroscopy in a micromachined flow cytometer: Theoretical and practical considerations. Lab Chip 2004, 4, 241-251
    • (2004) Lab Chip , vol.4 , pp. 241-251
    • Gawad, S.1    Cheung, K.2    Seger, U.3    Bertsch, A.4    Renaud, P.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.