메뉴 건너뛰기




Volumn 26, Issue 2, 2013, Pages 175-180

Survival rates of a lithium disilicate-based core ceramic for three-unit esthetic fixed partial dentures: A 10-year prospective study

Author keywords

[No Author keywords available]

Indexed keywords

DENTAL PORCELAIN; EMPRESS 2; GLASS CERAMICS; LITHIA DISILICATE; LITHIUM DERIVATIVE;

EID: 84879190143     PISSN: 08932174     EISSN: None     Source Type: Journal    
DOI: 10.11607/ijp.3045     Document Type: Article
Times cited : (48)

References (23)
  • 1
    • 0035515495 scopus 로고    scopus 로고
    • The safety and efficacy of anterior ceramic fixed partial dentures: A review of the literature
    • Raigrodski A, Chiche GJ. The safety and efficacy of anterior ceramic fixed partial dentures: A review of the literature. J Prosthet Dent 2001; 86: 520-525.
    • (2001) J Prosthet Dent , vol.86 , pp. 520-525
    • Raigrodski, A.1    Chiche, G.J.2
  • 2
    • 0033755414 scopus 로고    scopus 로고
    • Indications and potential of bonded metal-ceramic fixed partial dentures
    • Dietschi D. Indications and potential of bonded metal-ceramic fixed partial dentures. Pract Periodontics Aesthet Dent 2000; 12: 51-58.
    • (2000) Pract Periodontics Aesthet Dent , vol.12 , pp. 51-58
    • Dietschi, D.1
  • 3
    • 84979820266 scopus 로고    scopus 로고
    • An 18-year retrospective analysis of treatment outcomes with metal ceramic fixed partial dentures
    • Näpänkangas R, Raustia A. An 18-year retrospective analysis of treatment outcomes with metal ceramic fixed partial dentures. Int J Prosthodont 2011; 24: 314-319.
    • (2011) Int J Prosthodont , vol.24 , pp. 314-319
    • Näpänkangas, R.1    Raustia, A.2
  • 5
    • 84995796983 scopus 로고    scopus 로고
    • Zirconia in dentistry: Part 2. Evidence-base clinical breakthrough
    • Koutayas S, Vagkopoulou T. Zirconia in dentistry: Part 2. Evidence-base clinical breakthrough. Eur J Esthet Dent 2010; 2: 127-161.
    • (2010) Eur J Esthet Dent , vol.2 , pp. 127-161
    • Koutayas, S.1    Vagkopoulou, T.2
  • 7
    • 0034332357 scopus 로고    scopus 로고
    • Strength and microstructure of IPS Empress 2 glass-ceramic after different treatments
    • Oh SC, Dong JK, Lüthy H, Schärer P. Strength and microstructure of IPS Empress 2 glass-ceramic after different treatments. Int J Prosthodont 2000; 13: 468-472.
    • (2000) Int J Prosthodont , vol.13 , pp. 468-472
    • Oh, S.C.1    Dong, J.K.2    Lüthy, H.3    Schärer, P.4
  • 8
    • 16644392887 scopus 로고    scopus 로고
    • Biaxial flexural strength and microstructure changes of two recycled pressable glass ceramics
    • Albakry M, Guazzato M, Swain MV. Biaxial flexural strength and microstructure changes of two recycled pressable glass ceramics. J Prosthodont 2004; 13: 141-149.
    • (2004) J Prosthodont , vol.13 , pp. 141-149
    • Albakry, M.1    Guazzato, M.2    Swain, M.V.3
  • 9
    • 0007285056 scopus 로고    scopus 로고
    • A comparison of the microstructure and properties of the IPS Empress 2 and the IPS Empress glass-ceramics
    • Höland W, Schweiger M, Frank M, Rheinberger V. A comparison of the microstructure and properties of the IPS Empress 2 and the IPS Empress glass-ceramics. J Biomed Mater Res 2000; 53: 297-303.
    • (2000) J Biomed Mater Res , vol.53 , pp. 297-303
    • Höland, W.1    Schweiger, M.2    Frank, M.3    Rheinberger, V.4
  • 10
    • 0036580007 scopus 로고    scopus 로고
    • The effect of veneering and heat treatment on the flexural strength of Empress 2 ceramics
    • Cattell MJ, Palumbo RP, Knowles JC, Clarke RL, Samarawickrama DY. The effect of veneering and heat treatment on the flexural strength of Empress 2 ceramics. J Dent 2000; 30: 161-169.
    • (2000) J Dent , vol.30 , pp. 161-169
    • Cattell, M.J.1    Palumbo, R.P.2    Knowles, J.C.3    Clarke, R.L.4    Samarawickrama, D.Y.5
  • 11
    • 23844492202 scopus 로고    scopus 로고
    • Research diagnostic criteria for temporomandibular disorders: A calibration and reliability study
    • Schmitter M, Ohlmann B, John MT, Hirsch C, Rammelsberg P. Research diagnostic criteria for temporomandibular disorders: A calibration and reliability study. Cranio 2005; 23: 212-218.
    • (2005) Cranio , vol.23 , pp. 212-218
    • Schmitter, M.1    Ohlmann, B.2    John, M.T.3    Hirsch, C.4    Rammelsberg, P.5
  • 12
    • 32944470592 scopus 로고    scopus 로고
    • Translating the research diagnostic criteria for temporomandibular disorders into German: Evaluation of content and process
    • John MT, Hirsch C, Reiber T, Dworkin S. Translating the research diagnostic criteria for temporomandibular disorders into German: Evaluation of content and process. J Orofac Pain 2006; 20: 43-53.
    • (2006) J Orofac Pain , vol.20 , pp. 43-53
    • John, M.T.1    Hirsch, C.2    Reiber, T.3    Dworkin, S.4
  • 13
    • 0041734214 scopus 로고    scopus 로고
    • The IPS Empress 2 system: Defining the possibilities
    • Sorensen JA. The IPS Empress 2 system: Defining the possibilities. Quintessence Dent Technol 1999; 22: 153-163.
    • (1999) Quintessence Dent Technol , vol.22 , pp. 153-163
    • Sorensen, J.A.1
  • 14
    • 33749065120 scopus 로고    scopus 로고
    • Two-year clinical evaluation of lithiadisilicate- based all-ceramic crowns and fixed partial dentures
    • Taskonak B, Sertgöz A. Two-year clinical evaluation of lithiadisilicate- based all-ceramic crowns and fixed partial dentures. Dent Mater 2006; 22: 1008-1013.
    • (2006) Dent Mater , vol.22 , pp. 1008-1013
    • Taskonak, B.1    Sertgöz, A.2
  • 15
    • 42449126674 scopus 로고    scopus 로고
    • Four-year clinical performance of lithia disilicate-based core ceramic for posterior fixed partial dentures
    • Esquivel-Upshaw JF, Young J, Jones J, Yang M, Anusavice KJ. Four-year clinical performance of lithia disilicate-based core ceramic for posterior fixed partial dentures. Int J Prosthodont 2008; 21: 155-160.
    • (2008) Int J Prosthodont , vol.21 , pp. 155-160
    • Esquivel-Upshaw, J.F.1    Young, J.2    Jones, J.3    Yang, M.4    Anusavice, K.J.5
  • 16
    • 44849111859 scopus 로고    scopus 로고
    • Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs
    • Molin MK, Karlsson SL. Five-year clinical prospective evaluation of zirconia-based Denzir 3-unit FPDs. Int J Prosthodont 2008; 21: 223-227.
    • (2008) Int J Prosthodont , vol.21 , pp. 223-227
    • Molin, M.K.1    Karlsson, S.L.2
  • 17
    • 33645309086 scopus 로고    scopus 로고
    • Survival rates of IPS empress 2 allceramic crowns and fixed partial dentures: Results of a 5-year prospective clinical study
    • Marquardt P, Strub JR. Survival rates of IPS empress 2 allceramic crowns and fixed partial dentures: Results of a 5-year prospective clinical study. Quintessence Int 2006; 37: 253-259.
    • (2006) Quintessence Int , vol.37 , pp. 253-259
    • Marquardt, P.1    Strub, J.R.2
  • 18
    • 2342496788 scopus 로고    scopus 로고
    • Survival rate of IPS Empress 2 all-ceramic crowns and bridges. Three years’ results [in German]
    • Zimmer D, Gerdst T, Strub JR. Survival rate of IPS Empress 2 all-ceramic crowns and bridges. Three years’ results [in German]. Schweiz Monatssch Zahnmed 2004; 114: 115-119.
    • (2004) Schweiz Monatssch Zahnmed , vol.114 , pp. 115-119
    • Zimmer, D.1    Gerdst, T.2    Strub, J.R.3
  • 19
    • 67651124814 scopus 로고    scopus 로고
    • Clinical outcome of three-unit lithium-disilicate glass-ceramic fixed dental prostheses: Up to 8 years results
    • Wolfart S, Eschbach S, Scherrer S, Kern M. Clinical outcome of three-unit lithium-disilicate glass-ceramic fixed dental prostheses: Up to 8 years results. Dent Mater 2009; 25: 63-71.
    • (2009) Dent Mater , vol.25 , pp. 63-71
    • Wolfart, S.1    Eschbach, S.2    Scherrer, S.3    Kern, M.4
  • 20
    • 33749677224 scopus 로고    scopus 로고
    • The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study
    • Raigrodski AJ, Chiche GJ, Potiket N, et al. The efficacy of posterior three-unit zirconium-oxide-based ceramic fixed partial dental prostheses: A prospective clinical pilot study. J Prosthet Dent 2006; 96: 237-244.
    • (2006) J Prosthet Dent , vol.96 , pp. 237-244
    • Raigrodski, A.J.1    Chiche, G.J.2    Potiket, N.3
  • 22
    • 77952296078 scopus 로고    scopus 로고
    • Prospective evaluation of zirconia posterior fixed partial dentures: Four-year clinical results
    • Roediger M, Gersdorff N, Huels A, Rinke S. Prospective evaluation of zirconia posterior fixed partial dentures: Four-year clinical results. Int J Prosthodont 2010; 23: 141-148.
    • (2010) Int J Prosthodont , vol.23 , pp. 141-148
    • Roediger, M.1    Gersdorff, N.2    Huels, A.3    Rinke, S.4
  • 23
    • 77449113504 scopus 로고    scopus 로고
    • Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: A 3-year follow-up
    • Sailer I, Gottnerb J, Kanelb S, Hammerle CH. Randomized controlled clinical trial of zirconia-ceramic and metal-ceramic posterior fixed dental prostheses: A 3-year follow-up. Int J Prosthodont 2009; 22: 553-560.
    • (2009) Int J Prosthodont , vol.22 , pp. 553-560
    • Sailer, I.1    Gottnerb, J.2    Kanelb, S.3    Hammerle, C.H.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.