메뉴 건너뛰기




Volumn 60, Issue , 2013, Pages 45-51

Construction of triglyceride biosensor based on nickel oxide-chitosan/zinc oxide/zinc hexacyanoferrate film

Author keywords

Glycerol kinase; Glycerol 3 phosphate oxidase; Lipase; Nickel nanoparticles; Triglyceride

Indexed keywords

CHITOSAN; GLYCEROPHOSPHATE; NANOPARTICLE; NICKEL; TRIACYLGLYCEROL; UNCLASSIFIED DRUG; ZINC; ZINC HEXACYANOFERRATE; ZINC OXIDE;

EID: 84879146307     PISSN: 01418130     EISSN: 18790003     Source Type: Journal    
DOI: 10.1016/j.ijbiomac.2013.05.007     Document Type: Article
Times cited : (44)

References (32)
  • 3
    • 0025089253 scopus 로고
    • Triglyceride measurement: a review of methods and interferences
    • Klotzsch S.G., McNamara.J.R. Triglyceride measurement: a review of methods and interferences. Clinical Chemistry 1990, 36:1605-1613.
    • (1990) Clinical Chemistry , vol.36 , pp. 1605-1613
    • Klotzsch, S.G.1    McNamara, J.R.2
  • 4
    • 0019949179 scopus 로고
    • Serum triglycerides determined colorimetrically with an enzyme that produces hydrogen peroxide
    • Fossati P., Prencipe L. Serum triglycerides determined colorimetrically with an enzyme that produces hydrogen peroxide. Clinical Chemistry 1982, 28:2077-2080.
    • (1982) Clinical Chemistry , vol.28 , pp. 2077-2080
    • Fossati, P.1    Prencipe, L.2
  • 5
    • 0015847114 scopus 로고
    • Quantitative determination of serum triglycerides by the use of enzymes
    • Bucolo G., David H. Quantitative determination of serum triglycerides by the use of enzymes. Clinical Chemistry 1973, 19:476-482.
    • (1973) Clinical Chemistry , vol.19 , pp. 476-482
    • Bucolo, G.1    David, H.2
  • 6
    • 0028045744 scopus 로고
    • Rapid, sensitive fluorometric determination of serum triglyceride by measuring lipase liberated fatty acids
    • Voysey J.E., Wilton D.C. Rapid, sensitive fluorometric determination of serum triglyceride by measuring lipase liberated fatty acids. Clinical Chemistry 1994, 40:14-17.
    • (1994) Clinical Chemistry , vol.40 , pp. 14-17
    • Voysey, J.E.1    Wilton, D.C.2
  • 8
    • 0017144007 scopus 로고
    • Determination of serum triglycerides by mass fragmentograpy
    • Bjorkhem I., Blomstrand R., Svensson L. Determination of serum triglycerides by mass fragmentograpy. Clinica Chimica Acta 1976, 71:191-198.
    • (1976) Clinica Chimica Acta , vol.71 , pp. 191-198
    • Bjorkhem, I.1    Blomstrand, R.2    Svensson, L.3
  • 9
    • 0034994931 scopus 로고    scopus 로고
    • Porous silicon based potentiometric triglyceride biosensor
    • Reddy R., Anju R.C., Enakshi B. Porous silicon based potentiometric triglyceride biosensor. Biosensors and Bioelectronics 2001, 16:313-317.
    • (2001) Biosensors and Bioelectronics , vol.16 , pp. 313-317
    • Reddy, R.1    Anju, R.C.2    Enakshi, B.3
  • 10
    • 0020199181 scopus 로고
    • Amperometeric enzyme determination of triglyceride in serum
    • Winartasaputra H., Kutan S.S., Cuilbault G.C. Amperometeric enzyme determination of triglyceride in serum. Annali di Chimica 1982, 54:1987-1990.
    • (1982) Annali di Chimica , vol.54 , pp. 1987-1990
    • Winartasaputra, H.1    Kutan, S.S.2    Cuilbault, G.C.3
  • 11
    • 46449118519 scopus 로고    scopus 로고
    • Construction of an amperometric enzymic sensor for triglyceride determination
    • Minakshi, Pundir C.S. Construction of an amperometric enzymic sensor for triglyceride determination. Sensors and Actuators B: Chemical 2008, 133:251-325.
    • (2008) Sensors and Actuators B: Chemical , vol.133 , pp. 251-325
    • Minakshi1    Pundir, C.S.2
  • 12
    • 74349098828 scopus 로고    scopus 로고
    • Fabrication of an amperometric triglyceride biosensor based on PVC membrane
    • Narang J., Bhambi M., Minakshi, Pundir C.S. Fabrication of an amperometric triglyceride biosensor based on PVC membrane. Analytical Letters 2010, 40:1-10.
    • (2010) Analytical Letters , vol.40 , pp. 1-10
    • Narang, J.1    Bhambi, M.2    Minakshi3    Pundir, C.S.4
  • 13
    • 76749128874 scopus 로고    scopus 로고
    • Construction of an amperometric triglyceride biosensor using PVA membrane bound enzymes
    • Pundir C.S., Sandeep S., Bharvi, Narang J. Construction of an amperometric triglyceride biosensor using PVA membrane bound enzymes. Clinical Biochemistry 2010, 43:467-472.
    • (2010) Clinical Biochemistry , vol.43 , pp. 467-472
    • Pundir, C.S.1    Sandeep, S.2    Bharvi3    Narang, J.4
  • 14
    • 74349098828 scopus 로고    scopus 로고
    • Fabrication of an amperometric triglyceride biosensor based on PVC membrane
    • Narang J., Minakshi, Bhambi M., Pundir C.S. Fabrication of an amperometric triglyceride biosensor based on PVC membrane. Analytical Letters 2010, 40:1-10.
    • (2010) Analytical Letters , vol.40 , pp. 1-10
    • Narang, J.1    Minakshi2    Bhambi, M.3    Pundir, C.S.4
  • 15
    • 34249899451 scopus 로고    scopus 로고
    • Amperometric biosensor based on Prussian blue-modified screen-printed electrode for lipase activity and triacylglycerol determination
    • Rejeb I.B., Arduini F., Amine A., Gargouri M., Palleschi G. Amperometric biosensor based on Prussian blue-modified screen-printed electrode for lipase activity and triacylglycerol determination. Analytica Chimica Acta 2007, 594:1-8.
    • (2007) Analytica Chimica Acta , vol.594 , pp. 1-8
    • Rejeb, I.B.1    Arduini, F.2    Amine, A.3    Gargouri, M.4    Palleschi, G.5
  • 16
    • 56549111161 scopus 로고    scopus 로고
    • Detection of triglyceride using an iridium nano-particle catalyst based amperometric biosensor
    • Liao W.Y., Liu C.C., Chou T.C. Detection of triglyceride using an iridium nano-particle catalyst based amperometric biosensor. Analyst 2008, 133:1757-1763.
    • (2008) Analyst , vol.133 , pp. 1757-1763
    • Liao, W.Y.1    Liu, C.C.2    Chou, T.C.3
  • 17
    • 78349277613 scopus 로고    scopus 로고
    • Polyaniline/single-walled carbon nanotubes composite based triglyceride biosensor
    • Dhand C., Solanki P.R., Datta M., Malhotra B.D. Polyaniline/single-walled carbon nanotubes composite based triglyceride biosensor. Electroanalysis 2010, 22:2683-2693.
    • (2010) Electroanalysis , vol.22 , pp. 2683-2693
    • Dhand, C.1    Solanki, P.R.2    Datta, M.3    Malhotra, B.D.4
  • 19
    • 80052278080 scopus 로고    scopus 로고
    • Construction of a triglyceride amperometric biosensor based on chitosan-ZnO nanocomposite film
    • Narang J., Pundir C.S. Construction of a triglyceride amperometric biosensor based on chitosan-ZnO nanocomposite film. International Journal of Biological Macromolecules 2011, 49:707-715.
    • (2011) International Journal of Biological Macromolecules , vol.49 , pp. 707-715
    • Narang, J.1    Pundir, C.S.2
  • 20
    • 33744986798 scopus 로고
    • Electrochemistry of polynuclear transition metal cyanides: Prussian blue and its analogues
    • Itaya K., Uchida I., Neff V.D. Electrochemistry of polynuclear transition metal cyanides: Prussian blue and its analogues. Accounts of Chemical Research 1986, 19:162-168.
    • (1986) Accounts of Chemical Research , vol.19 , pp. 162-168
    • Itaya, K.1    Uchida, I.2    Neff, V.D.3
  • 21
    • 0002430856 scopus 로고
    • Molecular design of electrode surfaces
    • Wiley, Chichester
    • Murray R.W. Molecular design of electrode surfaces. Techniques of Chemistry Series 1992, vol. 22. Wiley, Chichester.
    • (1992) Techniques of Chemistry Series , vol.22
    • Murray, R.W.1
  • 22
    • 0000014215 scopus 로고
    • Chemically modified electrodes
    • Dekker, New York
    • Murray R.W. Chemically modified electrodes. Electroanalytical Chemistry 1984, vol. 13. Dekker, New York.
    • (1984) Electroanalytical Chemistry , vol.13
    • Murray, R.W.1
  • 23
    • 69249154942 scopus 로고
    • Electrochemical oxidation and reduction of thin-films of Prussian blue
    • Neff V.D. Electrochemical oxidation and reduction of thin-films of Prussian blue. Journal of the Electrochemical Society 1978, 125:886-887.
    • (1978) Journal of the Electrochemical Society , vol.125 , pp. 886-887
    • Neff, V.D.1
  • 25
    • 37549016452 scopus 로고    scopus 로고
    • Preparation, characterization and electrocatalytic behavior of zinc oxide/zinchexacyanoferrate and ruthenium oxide hexacyanoferrate hybrid film-modified electrodes
    • Chu H.-W., Thangamuthu R., Chen S.-M. Preparation, characterization and electrocatalytic behavior of zinc oxide/zinchexacyanoferrate and ruthenium oxide hexacyanoferrate hybrid film-modified electrodes. Electrochimica Acta 2008, 53:2862-2869.
    • (2008) Electrochimica Acta , vol.53 , pp. 2862-2869
    • Chu, H.-W.1    Thangamuthu, R.2    Chen, S.-M.3
  • 26
    • 79954619049 scopus 로고    scopus 로고
    • Synthesis and characterization of nano-dimensional nickelous oxide (NiO) semiconductor
    • Chakrabarty S., Chatterjee K. Synthesis and characterization of nano-dimensional nickelous oxide (NiO) semiconductor. Journal of Physical Science 2009, 13:245-250.
    • (2009) Journal of Physical Science , vol.13 , pp. 245-250
    • Chakrabarty, S.1    Chatterjee, K.2
  • 27
    • 33748316663 scopus 로고    scopus 로고
    • Direct voltammetry and electrocatalytic properties of hemoglobin immobilized on a glassy carbon electrode modified with nickel oxide nanoparticles
    • Salimi A., Sharifi E., Noorbakhsh A., Soltanian S. Direct voltammetry and electrocatalytic properties of hemoglobin immobilized on a glassy carbon electrode modified with nickel oxide nanoparticles. Electrochemistry Communications 2006, 8:1499-1508.
    • (2006) Electrochemistry Communications , vol.8 , pp. 1499-1508
    • Salimi, A.1    Sharifi, E.2    Noorbakhsh, A.3    Soltanian, S.4
  • 28
    • 84865761210 scopus 로고    scopus 로고
    • Synthesis of nano-sized nickel particles by a bottom-up approach in the presence of an anionic surfactant and a nonionic polymer
    • Hussain M.S., Haque K.M.A. Synthesis of nano-sized nickel particles by a bottom-up approach in the presence of an anionic surfactant and a nonionic polymer. Journal of Scientometric Research 2010, 2:313-321.
    • (2010) Journal of Scientometric Research , vol.2 , pp. 313-321
    • Hussain, M.S.1    Haque, K.M.A.2
  • 29
    • 84866536656 scopus 로고    scopus 로고
    • An amperometric glutathione biosensor based on chitosan-iron coated gold nanoparticles modified Pt electrode
    • Chauhan N., Narang J., Meena, Pundir C.S. An amperometric glutathione biosensor based on chitosan-iron coated gold nanoparticles modified Pt electrode. International Journal of Biological Macromolecules 2012, 51:879-886.
    • (2012) International Journal of Biological Macromolecules , vol.51 , pp. 879-886
    • Chauhan, N.1    Narang, J.2    Meena3    Pundir, C.S.4
  • 30
    • 0017202148 scopus 로고
    • A stable radioactive substrate emulsion for assay of lipoprotein lipase
    • Ehle N.P., Schotz C.M. A stable radioactive substrate emulsion for assay of lipoprotein lipase. Journal of Lipid Research 1976, 17:536-546.
    • (1976) Journal of Lipid Research , vol.17 , pp. 536-546
    • Ehle, N.P.1    Schotz, C.M.2
  • 31
    • 13644250984 scopus 로고    scopus 로고
    • Zinc hexacyanoferrate film as an effective protecting layer in two-step and one-step electropolymerization of pyrrole on zinc substrate
    • Pournaghi-Azar M.H., Nahalparvari H. Zinc hexacyanoferrate film as an effective protecting layer in two-step and one-step electropolymerization of pyrrole on zinc substrate. Electrochimica Acta 2005, 50:2107-2115.
    • (2005) Electrochimica Acta , vol.50 , pp. 2107-2115
    • Pournaghi-Azar, M.H.1    Nahalparvari, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.