메뉴 건너뛰기




Volumn 785, Issue , 2013, Pages 98-103

A novel quartz crystal microbalance gas sensor based on porous film coatings. A high sensitivity porous poly(methylmethacrylate) water vapor sensor

Author keywords

Gas sensor humidity; Poly(d,l lactide); Poly(methylmethacrylate); Quartz crystal microbalance

Indexed keywords

CHEMICAL SENSORS; GAS DETECTORS; PLASTIC COATINGS; POLYMER FILMS; QUARTZ; SEMICONDUCTING FILMS; SODIUM HYDROXIDE; WATER VAPOR;

EID: 84879003321     PISSN: 00032670     EISSN: 18734324     Source Type: Journal    
DOI: 10.1016/j.aca.2013.04.052     Document Type: Article
Times cited : (32)

References (16)
  • 1
    • 81555209817 scopus 로고    scopus 로고
    • Recent advances in quartz crystal microbalance-based sensors
    • Vashist S.K.V.a.P. Recent advances in quartz crystal microbalance-based sensors. J. Sens. 2011, 13.
    • (2011) J. Sens. , pp. 13
    • Vashist, S.1
  • 2
    • 0035449587 scopus 로고    scopus 로고
    • Molecular-imprinted, polymer-coated quartz crystal microbalances for the detection of terpenes
    • Percival C.J., Stanley S., Galle M., Braithwaite A., Newton M.I., McHale, Hayes W. Molecular-imprinted, polymer-coated quartz crystal microbalances for the detection of terpenes. Anal. Chem. 2001, 73(17):4225-4228.
    • (2001) Anal. Chem. , vol.73 , Issue.17 , pp. 4225-4228
    • Percival, C.J.1    Stanley, S.2    Galle, M.3    Braithwaite, A.4    Newton, M.I.5    McHale6    Hayes, W.7
  • 3
    • 19744365531 scopus 로고    scopus 로고
    • 2. Gas detector using morpholine-functional cross-linked copolymer coatings
    • 2. Gas detector using morpholine-functional cross-linked copolymer coatings. Sens. Actuators B: Chem. 2005, 108(1-2):572-575.
    • (2005) Sens. Actuators B: Chem. , vol.108 , Issue.1-2 , pp. 572-575
    • Matsuguchi, M.1    Kadowaki, Y.2    Tanaka, M.3
  • 5
    • 36849048053 scopus 로고    scopus 로고
    • Quartz crystal microbalance coated with sol-gel-derived thin films as gas sensor for no detection
    • Zhang J., Hu J., Zhu F., Gong H., O'Shea S. Quartz crystal microbalance coated with sol-gel-derived thin films as gas sensor for no detection. Sensors 2003, 3(10):404-414.
    • (2003) Sensors , vol.3 , Issue.10 , pp. 404-414
    • Zhang, J.1    Hu, J.2    Zhu, F.3    Gong, H.4    O'Shea, S.5
  • 6
    • 0002673413 scopus 로고    scopus 로고
    • High performance smell sensor using spatially controlled LB films with polymer backbone
    • Sha Shiratori S., Kohno K., Yamada M. High performance smell sensor using spatially controlled LB films with polymer backbone. Sens. Actuators B: Chem. 2000, 64(1-3):70-75.
    • (2000) Sens. Actuators B: Chem. , vol.64 , Issue.1-3 , pp. 70-75
    • Sha Shiratori, S.1    Kohno, K.2    Yamada, M.3
  • 8
    • 0024607398 scopus 로고
    • Monitoring the growth of an oxide film on aluminum in situ with the quartz crystal microbalance
    • Deakin M.R., Melroy O.R. Monitoring the growth of an oxide film on aluminum in situ with the quartz crystal microbalance. J. Electrochem. Soc. 1989, 136(2):349-352.
    • (1989) J. Electrochem. Soc. , vol.136 , Issue.2 , pp. 349-352
    • Deakin, M.R.1    Melroy, O.R.2
  • 9
    • 32044453132 scopus 로고    scopus 로고
    • A highly stable quartz crystal microbalance sensor and its application to water vapor measurements
    • Kwon S.-Y., Choi B.-I., Kim J.-C., Nham H.S. A highly stable quartz crystal microbalance sensor and its application to water vapor measurements. J. Korean Phys. Soc. 2006, 48(1):5.
    • (2006) J. Korean Phys. Soc. , vol.48 , Issue.1 , pp. 5
    • Kwon, S.-Y.1    Choi, B.-I.2    Kim, J.-C.3    Nham, H.S.4
  • 10
    • 84869387344 scopus 로고    scopus 로고
    • Using plasticizers to control the hydrocarbon selectivity of a poly(methyl methacrylate)-coated quartz crystal microbalance sensor
    • Pejcic B., Crooke E., Boyd L., Doherty C.M., Hill A.J., Myers M., White C. Using plasticizers to control the hydrocarbon selectivity of a poly(methyl methacrylate)-coated quartz crystal microbalance sensor. Anal. Chem. 2012, 84(20):8564-8570.
    • (2012) Anal. Chem. , vol.84 , Issue.20 , pp. 8564-8570
    • Pejcic, B.1    Crooke, E.2    Boyd, L.3    Doherty, C.M.4    Hill, A.J.5    Myers, M.6    White, C.7
  • 12
    • 0022080094 scopus 로고
    • An in situ weighing study of the mechanism for the formation of the adsorbed oxygen monolayer at a gold electrode
    • Bruckenstein S., Shay M. An in situ weighing study of the mechanism for the formation of the adsorbed oxygen monolayer at a gold electrode. J. Electroanal. Chem. Interfacial Electrochem. 1985, 188(1-2):131-136.
    • (1985) J. Electroanal. Chem. Interfacial Electrochem. , vol.188 , Issue.1-2 , pp. 131-136
    • Bruckenstein, S.1    Shay, M.2
  • 13
    • 0032704734 scopus 로고    scopus 로고
    • Commercial quartz crystal microbalances - theory and applications
    • O'Sullivan C.K., Guilbault G.G. Commercial quartz crystal microbalances - theory and applications. Biosens. Bioelectron. 1999, 14(8-9):663-670.
    • (1999) Biosens. Bioelectron. , vol.14 , Issue.8-9 , pp. 663-670
    • O'Sullivan, C.K.1    Guilbault, G.G.2
  • 14
    • 84951279351 scopus 로고
    • Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung
    • Sauerbrey G. Verwendung von Schwingquarzen zur Wägung dünner Schichten und zur Mikrowägung. Zeitschrift für Physik. 1959, 155(2):206-222.
    • (1959) Zeitschrift für Physik. , vol.155 , Issue.2 , pp. 206-222
    • Sauerbrey, G.1
  • 16
    • 34249893641 scopus 로고    scopus 로고
    • Fabrication of porous alumina on quartz crystal microbalances
    • Lazarowich R.J., Taborek P., Yoo B.Y., Myung N.V. Fabrication of porous alumina on quartz crystal microbalances. J. Appl. Phys. 2007, 101(10):104909-104917.
    • (2007) J. Appl. Phys. , vol.101 , Issue.10 , pp. 104909-104917
    • Lazarowich, R.J.1    Taborek, P.2    Yoo, B.Y.3    Myung, N.V.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.