메뉴 건너뛰기




Volumn 1, Issue 2, 2011, Pages 195-210

Bayesian analysis for causes of failure at a water utility

Author keywords

A posteriori; A priori; Bayes theorem; Corrosion; Pipes; Preventive maintenance; Probability of failure; Replacement; Water supply engineering

Indexed keywords


EID: 84878812717     PISSN: 2044124X     EISSN: 20441258     Source Type: Journal    
DOI: 10.1108/20441241111180433     Document Type: Article
Times cited : (7)

References (14)
  • 1
    • 84878775659 scopus 로고    scopus 로고
    • BWS, available at, Board of Water Supply, Honolulu, HI
    • BWS (2009), BWS Final Annual Report, Board of Water Supply, Honolulu, HI, available at: www.boardofwatersupply.com/files/2009%20BWS%20final%20annual%20report.pdf.
    • (2009) BWS Final Annual Report
  • 2
    • 69249135541 scopus 로고    scopus 로고
    • Multiobjective approach for pipe replacement based on Bayesian inference of break model parameters
    • Dridi, L., Mailhot, A., Parizeau, M., Villeneuve, J. (2009), "Multiobjective approach for pipe replacement based on Bayesian inference of break model parameters" in Journal of Water Resources Planning and Management, Vol. 135, No. 5, pp. 344-54.
    • (2009) Journal of Water Resources Planning and Management , vol.135 , Issue.5 , pp. 344-354
    • Dridi, L.1    Mailhot, A.2    Parizeau, M.3    Villeneuve, J.4
  • 5
    • 0022077716 scopus 로고
    • An analysis of pipe breakage in urban water distribution networks
    • Kettler, A.J., Goulter, I.C. (1985), "An analysis of pipe breakage in urban water distribution networks" in Canadian Journal of Civil Engrg, Vol. 12, No. 13, pp. 286-93.
    • (1985) Canadian Journal of Civil Engrg , vol.12 , Issue.13 , pp. 286-293
    • Kettler, A.J.1    Goulter, I.C.2
  • 7
    • 84860829606 scopus 로고    scopus 로고
    • Honolulu Board of Water Supply, Honolulu, HI
    • MBreak (2009), Excel Data, Honolulu Board of Water Supply, Honolulu, HI.
    • (2009) Excel Data
    • MBreak1
  • 8
    • 33646583524 scopus 로고    scopus 로고
    • Decision support system for water pipeline renewal prioritisation
    • Moglia, M., Burn, S., Meddlings, S. (2006), "Decision support system for water pipeline renewal prioritisation" in ITcon, Vol. 11, pp. 237-56.
    • (2006) ITcon , vol.11 , pp. 237-256
    • Moglia, M.1    Burn, S.2    Meddlings, S.3
  • 9
    • 0020205298 scopus 로고
    • Organizing and analyzing leak and break data for making main replacement decisions
    • O'Day, D.K. (1982), "Organizing and analyzing leak and break data for making main replacement decisions" in Journal of AWWA, Vol. 74, No. 11, pp. 588-94.
    • (1982) Journal of AWWA , vol.74 , Issue.11 , pp. 588-594
    • O'Day, D.K.1
  • 10
    • 0018318075 scopus 로고
    • An analytic approach to scheduling pipe replacement
    • Shamir, U., Howard, C.D.D. (1979), "An analytic approach to scheduling pipe replacement" in Journal of AWWA, Vol. 71, No. 5, pp. 248-58.
    • (1979) Journal of AWWA , vol.71 , Issue.5 , pp. 248-258
    • Shamir, U.1    Howard, C.D.D.2
  • 12
    • 77954507000 scopus 로고    scopus 로고
    • An assessment model of water pipe condition using Bayesian inference
    • Wang, C., Niu, Z., Jia, H., Zhang, H. (2010), "An assessment model of water pipe condition using Bayesian inference" in Journal of Zhejiang Univ-Sci A (Appl Phys & Eng), Vol. 11, No. 7, pp. 495-504.
    • (2010) Journal of Zhejiang Univ-Sci A (Appl Phys & Eng) , vol.11 , Issue.7 , pp. 495-504
    • Wang, C.1    Niu, Z.2    Jia, H.3    Zhang, H.4
  • 14
    • 0020116519 scopus 로고
    • Cathodic protection of water mains
    • Westerback, A.E. (1982), "Cathodic protection of water mains" in Public Works, Vol. 113, No. 4, pp. 49-53.
    • (1982) Public Works , vol.113 , Issue.4 , pp. 49-53
    • Westerback, A.E.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.