Volumn 31, Issue 6, 2013, Pages 1012-1016

Evaluation of MRI fat fraction in the liver and spine pre and post SPIO infusion

Author keywords

Fat fractionSPIO; Liver; MRI; Spine; SPIO

Indexed keywords

SUPERPARAMAGNETIC IRON OXIDE;

EID: 84878660656     PISSN: 0730725X     EISSN: 18735894     Source Type: Journal    
DOI: 10.1016/j.mri.2013.01.016     Document Type: Article
Times cited : (20)

References (16)
  • 1
    • 51449106071 scopus 로고    scopus 로고
    • Dixon techniques for water and fat imaging
    • Ma J. Dixon techniques for water and fat imaging. J Magn Reson Imaging 2008, 28(3):543-558.
    • (2008) J Magn Reson Imaging , vol.28 , Issue.3 , pp. 543-558
    • Ma, J.1
  • 2
    • 84863852410 scopus 로고    scopus 로고
    • ISMRM workshop on fat-water separation: insights, applications and progress in MRI
    • Hu H.H., Bornert P., Hernando D., et al. ISMRM workshop on fat-water separation: insights, applications and progress in MRI. Magn Reson Med 2012, 68(2):378-388.
    • (2012) Magn Reson Med , vol.68 , Issue.2 , pp. 378-388
    • Hu, H.H.1    Bornert, P.2    Hernando, D.3
  • 3
    • 84867834721 scopus 로고    scopus 로고
    • Proton density fat-fraction: a standardized MR-based biomarker of tissue fat concentration
    • Reeder S.B., Hu H.H., Sirlin C.B. Proton density fat-fraction: a standardized MR-based biomarker of tissue fat concentration. J Magn Reson Imaging 2012, 36(5):1011-1014.
    • (2012) J Magn Reson Imaging , vol.36 , Issue.5 , pp. 1011-1014
    • Reeder, S.B.1    Hu, H.H.2    Sirlin, C.B.3
  • 4
    • 40249090380 scopus 로고    scopus 로고
    • Relaxation effects in the quantification of fat using gradient echo imaging
    • Bydder M., Yokoo T., Hamilton G., et al. Relaxation effects in the quantification of fat using gradient echo imaging. Magn Reson Imaging 2008, 26(3):347-359.
    • (2008) Magn Reson Imaging , vol.26 , Issue.3 , pp. 347-359
    • Bydder, M.1    Yokoo, T.2    Hamilton, G.3
  • 5
    • 23244463430 scopus 로고    scopus 로고
    • Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging
    • Reeder S.B., Pineda A.R., Wen Z., et al. Iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL): application with fast spin-echo imaging. Magn Reson Med 2005, 54(3):636-644.
    • (2005) Magn Reson Med , vol.54 , Issue.3 , pp. 636-644
    • Reeder, S.B.1    Pineda, A.R.2    Wen, Z.3
  • 6
    • 55749085613 scopus 로고    scopus 로고
    • Multiecho water-fat separation and simultaneous R2* estimation with multifrequency fat spectrum modeling
    • Yu H., Shimakawa A., McKenzie C.A., Brodsky E., Brittain J.H., Reeder S.B. Multiecho water-fat separation and simultaneous R2* estimation with multifrequency fat spectrum modeling. Magn Reson Med 2008, 60(5):1122-1134.
    • (2008) Magn Reson Med , vol.60 , Issue.5 , pp. 1122-1134
    • Yu, H.1    Shimakawa, A.2    McKenzie, C.A.3    Brodsky, E.4    Brittain, J.H.5    Reeder, S.B.6
  • 7
    • 79959539203 scopus 로고    scopus 로고
    • Combination of complex-based and magnitude-based multiecho water-fat separation for accurate quantification of fat-fraction
    • Yu H., Shimakawa A., Hines C.D., et al. Combination of complex-based and magnitude-based multiecho water-fat separation for accurate quantification of fat-fraction. Magn Reson Med 2011, 66(1):199-206.
    • (2011) Magn Reson Med , vol.66 , Issue.1 , pp. 199-206
    • Yu, H.1    Shimakawa, A.2    Hines, C.D.3
  • 8
    • 77953809119 scopus 로고    scopus 로고
    • Assessment of liver fat quantification in the presence of iron
    • Bydder M., Shiehmorteza M., Yokoo T., et al. Assessment of liver fat quantification in the presence of iron. Magn Reson Imaging 2010, 28(6):767-776.
    • (2010) Magn Reson Imaging , vol.28 , Issue.6 , pp. 767-776
    • Bydder, M.1    Shiehmorteza, M.2    Yokoo, T.3
  • 10
    • 84872971012 scopus 로고    scopus 로고
    • Comparison of R2* correction methods for accurate fat quantification in fatty liver
    • Horng D., Hernando D., Hines C., Reeder S. Comparison of R2* correction methods for accurate fat quantification in fatty liver. J Magn Reson Imaging 2013, 37(2):414-422.
    • (2013) J Magn Reson Imaging , vol.37 , Issue.2 , pp. 414-422
    • Horng, D.1    Hernando, D.2    Hines, C.3    Reeder, S.4
  • 12
    • 84872170621 scopus 로고    scopus 로고
    • Prospective study of functional bone marrow-sparing intensity modulated radiation therapy with concurrent chemotherapy for pelvic malignancies
    • Liang Y., Bydder M., Yashar C.M., et al. Prospective study of functional bone marrow-sparing intensity modulated radiation therapy with concurrent chemotherapy for pelvic malignancies. Int J Radiat Oncol Biol Phys 2013, 85(2):406-414.
    • (2013) Int J Radiat Oncol Biol Phys , vol.85 , Issue.2 , pp. 406-414
    • Liang, Y.1    Bydder, M.2    Yashar, C.M.3
  • 13
    • 84867025341 scopus 로고    scopus 로고
    • Hepatic steatosis assessment with (1)H-spectroscopy and chemical shift imaging at 3.0T before hepatic surgery: reliable enough for making clinical decisions?
    • Koelblinger C., Krssak M., Maresch J., et al. Hepatic steatosis assessment with (1)H-spectroscopy and chemical shift imaging at 3.0T before hepatic surgery: reliable enough for making clinical decisions?. Eur J Radiol 2012, 81(11):2990-2995.
    • (2012) Eur J Radiol , vol.81 , Issue.11 , pp. 2990-2995
    • Koelblinger, C.1    Krssak, M.2    Maresch, J.3
  • 14
    • 27144532730 scopus 로고    scopus 로고
    • Accuracy of liver fat quantification at MR imaging: comparison of out-of-phase gradient-echo and fat-saturated fast spin-echo techniques-initial experience
    • Qayyum A., Goh J.S., Kakar S., Yeh B.M., Merriman R.B., Coakley F.V. Accuracy of liver fat quantification at MR imaging: comparison of out-of-phase gradient-echo and fat-saturated fast spin-echo techniques-initial experience. Radiology 2005, 237(2):507-511.
    • (2005) Radiology , vol.237 , Issue.2 , pp. 507-511
    • Qayyum, A.1    Goh, J.S.2    Kakar, S.3    Yeh, B.M.4    Merriman, R.B.5    Coakley, F.V.6
  • 15
    • 85027925485 scopus 로고    scopus 로고
    • Correlation between liver histology and novel magnetic resonance imaging in adult patients with non-alcoholic fatty liver disease - MRI accurately quantifies hepatic steatosis in NAFLD
    • Permutt Z., Le T.A., Peterson M.R., et al. Correlation between liver histology and novel magnetic resonance imaging in adult patients with non-alcoholic fatty liver disease - MRI accurately quantifies hepatic steatosis in NAFLD. Aliment Pharmacol Ther 2012, 36(1):22-29.
    • (2012) Aliment Pharmacol Ther , vol.36 , Issue.1 , pp. 22-29
    • Permutt, Z.1    Le, T.A.2    Peterson, M.R.3
  • 16
    • 84867824543 scopus 로고    scopus 로고
    • Quantification of hepatic macrosteatosis in living, related liver donors using T1-independent, T2*-corrected chemical shift MRI
    • Joe E., Lee J.M., Kim K.W., et al. Quantification of hepatic macrosteatosis in living, related liver donors using T1-independent, T2*-corrected chemical shift MRI. J Magn Reson Imaging 2012.
    • (2012) J Magn Reson Imaging
    • Joe, E.1    Lee, J.M.2    Kim, K.W.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.