메뉴 건너뛰기




Volumn 53, Issue 7, 2013, Pages 1251-1258

Ultrasonic monitoring of erosion/corrosion thinning rates in industrial piping systems

Author keywords

Corrosion measurement; Cross correlation; Model based estimation; Ultrasound

Indexed keywords

CORROSION MEASUREMENTS; CROSS CORRELATION TECHNIQUES; CROSS CORRELATIONS; MODEL-BASED ESTIMATION; POLYNOMIAL CURVE FITTING; POWER GENERATION INDUSTRIES; SIGNAL PROCESSING TECHNIQUE; ULTRASONIC MONITORING;

EID: 84878603214     PISSN: 0041624X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.ultras.2013.03.007     Document Type: Conference Paper
Times cited : (74)

References (24)
  • 2
    • 78049340634 scopus 로고    scopus 로고
    • Case studies of pulsed eddy current to measure wall loss in feedwater piping and heater shells
    • N.P. Odowd (Ed.) Pt a and B
    • M.J. Cohn, J.W. Norton, Case studies of pulsed eddy current to measure wall loss in feedwater piping and heater shells, in: N.P. Odowd (Ed.), Proceedings of the Asme Pressure Vessels and Piping Conference - 2008, vol. 6, Pt a and B, 2009, pp. 721-731.
    • (2009) Proceedings of the Asme Pressure Vessels and Piping Conference - 2008 , vol.6 , pp. 721-731
    • Cohn, M.J.1    Norton, J.W.2
  • 3
    • 77957987180 scopus 로고    scopus 로고
    • A combined approach for high-resolution corrosion monitoring and temperature compensation using ultrasound
    • T. Rommetveit, T.F. Johansen, and R. Johnsen A combined approach for high-resolution corrosion monitoring and temperature compensation using ultrasound IEEE Trans. Instrum. Meas. 59 11 2010 2843 2853
    • (2010) IEEE Trans. Instrum. Meas. , vol.59 , Issue.11 , pp. 2843-2853
    • Rommetveit, T.1    Johansen, T.F.2    Johnsen, R.3
  • 4
    • 67650266274 scopus 로고    scopus 로고
    • Reduction of echo decorrelation via complex principal component filtering
    • F.W. Mauldin Jr, F. Viola, and W.F. Walker Reduction of echo decorrelation via complex principal component filtering Ultrasound Med. Biol. 35 8 2009 1325 1343
    • (2009) Ultrasound Med. Biol. , vol.35 , Issue.8 , pp. 1325-1343
    • Mauldin, Jr.F.W.1    Viola, F.2    Walker, W.F.3
  • 5
    • 84878618722 scopus 로고    scopus 로고
    • Corrpro Companies Inc., H., TX 77040, USA
    • Corrpro Companies Inc., H., TX 77040, USA < http://www.corrpro.com >.
  • 6
    • 84878581848 scopus 로고    scopus 로고
    • Corrocean S.r.l., R., Italy
    • Corrocean S.r.l., R., Italy < http://www.corrocean.it >.
  • 7
    • 84878598352 scopus 로고    scopus 로고
    • Sensor system monitors corrosion damage
    • D. Morison Sensor system monitors corrosion damage Mater. Perform. 2006
    • (2006) Mater. Perform.
    • Morison, D.1
  • 8
    • 0030653882 scopus 로고    scopus 로고
    • Accelerated corrosion of CANDU outlet feeders - Observations, possible mechanisms and potential remedies
    • D.H. Lister, J. Slade, N. Arbeau, Accelerated corrosion of CANDU outlet feeders - observations, possible mechanisms and potential remedies, in: Annual Conference of Canadian Nuclear Association, 1997.
    • (1997) Annual Conference of Canadian Nuclear Association
    • Lister, D.H.1    Slade, J.2    Arbeau, N.3
  • 9
    • 78149481155 scopus 로고    scopus 로고
    • A review of CANDU feeder wall thinning
    • H.S. Chung A review of CANDU feeder wall thinning Nucl. Eng. Technol. 42 5 2010 568 575
    • (2010) Nucl. Eng. Technol. , vol.42 , Issue.5 , pp. 568-575
    • Chung, H.S.1
  • 12
    • 66749137105 scopus 로고    scopus 로고
    • Time-delay estimation in ultrasound echo signals using individual sample tracking
    • R. Zahiri-Azar, and S.E. Salcudean Time-delay estimation in ultrasound echo signals using individual sample tracking IEEE Trans. Ultrason. Ferroelectr. Freq. Control 55 12 2008 2640 2650
    • (2008) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.55 , Issue.12 , pp. 2640-2650
    • Zahiri-Azar, R.1    Salcudean, S.E.2
  • 13
    • 28444459569 scopus 로고    scopus 로고
    • Digital ultrasonic pulse-echo overlap system and algorithm for unambiguous determination of pulse transit time
    • C. Pantea Digital ultrasonic pulse-echo overlap system and algorithm for unambiguous determination of pulse transit time Rev. Sci. Instrum. 76 11 2005 114902
    • (2005) Rev. Sci. Instrum. , vol.76 , Issue.11 , pp. 114902
    • Pantea, C.1
  • 14
    • 84878584661 scopus 로고    scopus 로고
    • Estimation of erosion/corrosion rate in pipe walls by cross-correlation technique
    • Burlington Vermont, USA
    • F. Honarvar Estimation of erosion/corrosion rate in pipe walls by cross-correlation technique Review of Progress in Quantitative Nondestructive Evaluation 2011 Burlington Vermont, USA
    • (2011) Review of Progress in Quantitative Nondestructive Evaluation
    • Honarvar, F.1
  • 17
    • 1342281371 scopus 로고    scopus 로고
    • Improving the time-resolution and signal-to-noise ratio of ultrasonic NDE signals
    • F. Honarvar Improving the time-resolution and signal-to-noise ratio of ultrasonic NDE signals Ultrasonics 41 9 2004 755 763
    • (2004) Ultrasonics , vol.41 , Issue.9 , pp. 755-763
    • Honarvar, F.1
  • 18
    • 0035324490 scopus 로고    scopus 로고
    • Model-based estimation of ultrasonic echoes part I: Analysis and algorithms
    • R. Demirli, and J. Saniie Model-based estimation of ultrasonic echoes part I: Analysis and algorithms IEEE Trans. Ultrason. Ferroelectr. Freq. Control 48 3 2001 787 802
    • (2001) IEEE Trans. Ultrason. Ferroelectr. Freq. Control , vol.48 , Issue.3 , pp. 787-802
    • Demirli, R.1    Saniie, J.2
  • 19
    • 0000169232 scopus 로고
    • An algorithm for least-squares estimation of nonlinear parameters
    • D. Marquardt An algorithm for least-squares estimation of nonlinear parameters SIAM J. Appl. Math. 11 1963 431 441
    • (1963) SIAM J. Appl. Math. , vol.11 , pp. 431-441
    • Marquardt, D.1
  • 21
    • 69349103943 scopus 로고    scopus 로고
    • Baltzersen, Using ultrasound measurement for real-time process control of pipelines and process equipment subjected to corrosion and/or erosion
    • New Orleans, LA Paper 08285
    • T. Rommetveit, R. Johnsen, ∅. Baltzersen, Using ultrasound measurement for real-time process control of pipelines and process equipment subjected to corrosion and/or erosion, in: Corrosion, New Orleans, LA, 2008. p. Paper 08285.
    • (2008) Corrosion
    • Rommetveit, T.1    Johnsen, R.2
  • 22
    • 0027625411 scopus 로고
    • Ultrasonic measurement of longitudinal and shear velocities of materials at elevated-temperatures
    • D.K. Mak, and J. Gauthier Ultrasonic measurement of longitudinal and shear velocities of materials at elevated-temperatures Ultrasonics 31 4 1993 245 249
    • (1993) Ultrasonics , vol.31 , Issue.4 , pp. 245-249
    • Mak, D.K.1    Gauthier, J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.