메뉴 건너뛰기




Volumn 18, Issue 6, 2013, Pages 634-640

Minimally invasive pedicle screw fixation combined with percutaneous vertebroplasty in the surgical treatment of thoracolumbar osteoporosis fracture

Author keywords

Minimally invasive spinal surgery; Osteoporosis; Pedicle screw fixation; Percutaneous surgery; Surgical technique; Thoracolumbar vertebral fracture; Vertebroplasty

Indexed keywords

ACUTE DISEASE; AGED; ARTICLE; CLINICAL ARTICLE; COBB ANGLE; COMPRESSION FRACTURE; CONTROLLED STUDY; FEASIBILITY STUDY; FEMALE; HUMAN; MALE; MINIMALLY INVASIVE SURGERY; OSTEOPOROSIS; PAIN ASSESSMENT; PATIENT SAFETY; PEDICLE SCREW; PERCUTANEOUS VERTEBROPLASTY; POSTOPERATIVE PERIOD; SPINE STABILIZATION; THORACOLUMBAR SPINE; VERTEBRA BODY; VISUAL ANALOG SCALE;

EID: 84878543578     PISSN: 15475654     EISSN: 15475646     Source Type: Journal    
DOI: 10.3171/2013.3.SPINE12827     Document Type: Article
Times cited : (36)

References (55)
  • 1
    • 78650957395 scopus 로고    scopus 로고
    • The economics of minimally invasive spine surgery: The value perspective
    • Allen RT, Garfin SR: The economics of minimally invasive spine surgery: the value perspective. Spine (Phila Pa 1976) 35 (26 Suppl):S375-S382, 2010
    • (2010) Spine (Phila Pa 1976) , vol.35 , Issue.26 SUPPL.
    • Allen, R.T.1    Garfin, S.R.2
  • 2
    • 34247164791 scopus 로고    scopus 로고
    • Pain relief following percutaneous vertebroplasty: Results of a series of 283 consecutive patients treated in a single institution
    • Anselmetti GC, Corrao G, Monica PD, Tartaglia V, Manca A, Eminefendic H, et al: Pain relief following percutaneous vertebroplasty: results of a series of 283 consecutive patients treated in a single institution. Cardiovasc Intervent Radiol 30:441-447, 2007
    • (2007) Cardiovasc Intervent Radiol , vol.30 , pp. 441-447
    • Anselmetti, G.C.1    Corrao, G.2    Monica, P.D.3    Tartaglia, V.4    Manca, A.5    Eminefendic, H.6
  • 3
    • 0032810055 scopus 로고    scopus 로고
    • The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures
    • Bai B, Jazrawi LM, Kummer FJ, Spivak JM: The use of an injectable, biodegradable calcium phosphate bone substitute for the prophylactic augmentation of osteoporotic vertebrae and the management of vertebral compression fractures. Spine (Phila Pa 1976) 24:1521-1526, 1999
    • (1999) Spine (Phila Pa 1976) , vol.24 , pp. 1521-1526
    • Bai, B.1    Jazrawi, L.M.2    Kummer, F.J.3    Spivak, J.M.4
  • 4
    • 0034655411 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for pain relief and spinal stabilization
    • Barr JD, Barr MS, Lemley TJ, McCann RM: Percutaneous vertebroplasty for pain relief and spinal stabilization. Spine (Phila Pa 1976) 25:923-928, 2000
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 923-928
    • Barr, J.D.1    Barr, M.S.2    Lemley, T.J.3    McCann, R.M.4
  • 5
    • 0032803123 scopus 로고    scopus 로고
    • An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty
    • Belkoff SM, Maroney M, Fenton DC, Mathis JM: An in vitro biomechanical evaluation of bone cements used in percutaneous vertebroplasty. Bone 25 (2 Suppl):23S-26S, 1999
    • (1999) Bone , vol.25 , Issue.2 SUPPL.
    • Belkoff, S.M.1    Maroney, M.2    Fenton, D.C.3    Mathis, J.M.4
  • 6
    • 0034951131 scopus 로고    scopus 로고
    • An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty
    • Belkoff SM, Mathis JM, Deramond H, Jasper LE: An ex vivo biomechanical evaluation of a hydroxyapatite cement for use with kyphoplasty. AJNR Am J Neuroradiol 22:1212-1216, 2001
    • (2001) AJNR Am J Neuroradiol , vol.22 , pp. 1212-1216
    • Belkoff, S.M.1    Mathis, J.M.2    Deramond, H.3    Jasper, L.E.4
  • 7
    • 0034193728 scopus 로고    scopus 로고
    • Biomechanical evaluation of a new bone cement for use in vertebroplasty
    • Belkoff SM, Mathis JM, Erbe EM, Fenton DC: Biomechanical evaluation of a new bone cement for use in vertebroplasty. Spine (Phila Pa 1976) 25:1061-1064, 2000
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 1061-1064
    • Belkoff, S.M.1    Mathis, J.M.2    Erbe, E.M.3    Fenton, D.C.4
  • 9
    • 0032846650 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: An open prospective study
    • Cortet B, Cotten A, Boutry N, Flipo RM, Duquesnoy B, Chastanet P, et al: Percutaneous vertebroplasty in the treatment of osteoporotic vertebral compression fractures: an open prospective study. J Rheumatol 26:2222-2228, 1999
    • (1999) J Rheumatol , vol.26 , pp. 2222-2228
    • Cortet, B.1    Cotten, A.2    Boutry, N.3    Flipo, R.M.4    Duquesnoy, B.5    Chastanet, P.6
  • 10
    • 0031930838 scopus 로고    scopus 로고
    • Mechanical stability of the AO internal spinal fixation system compared with that of the Hartshill rectangle and sublaminar wiring in the management of unstable burst fractures of the thoracic and lumbar spine
    • Cresswell TR, Marshall PD, Smith RB: Mechanical stability of the AO internal spinal fixation system compared with that of the Hartshill rectangle and sublaminar wiring in the management of unstable burst fractures of the thoracic and lumbar spine. Spine (Phila Pa 1976) 23:111-115, 1998
    • (1998) Spine (Phila Pa 1976) , vol.23 , pp. 111-115
    • Cresswell, T.R.1    Marshall, P.D.2    Smith, R.B.3
  • 11
    • 0037294219 scopus 로고    scopus 로고
    • Vertebral compression fractures: Pain reduction and improvement in functional mobility after percutaneous polymethylmethacrylate vertebroplasty retrospective report of 245 cases
    • Evans AJ, Jensen ME, Kip KE, DeNardo AJ, Lawler GJ, Negin GA, et al: Vertebral compression fractures: pain reduction and improvement in functional mobility after percutaneous polymethylmethacrylate vertebroplasty retrospective report of 245 cases. Radiology 226:366-372, 2003
    • (2003) Radiology , vol.226 , pp. 366-372
    • Evans, A.J.1    Jensen, M.E.2    Kip, K.E.3    Denardo, A.J.4    Lawler, G.J.5    Negin, G.A.6
  • 12
    • 34748879942 scopus 로고    scopus 로고
    • Percutaneous vertebral augmentation: An elevation in adjacent-level fracture risk in kyphoplasty as compared with vertebroplasty
    • Frankel BM, Monroe T, Wang C: Percutaneous vertebral augmentation: an elevation in adjacent-level fracture risk in kyphoplasty as compared with vertebroplasty. Spine J 7:575- 582, 2007
    • (2007) Spine J , vol.7 , pp. 575-582
    • Frankel, B.M.1    Monroe, T.2    Wang, C.3
  • 14
    • 77956935649 scopus 로고    scopus 로고
    • Percutaneous kyphoplasty and pedicle screw fixation for the management of thoraco-lumbar burst fractures
    • Fuentes S, Blondel B, Metellus P, Gaudart J, Adetchessi T, Dufour H: Percutaneous kyphoplasty and pedicle screw fixation for the management of thoraco-lumbar burst fractures. Eur Spine J 19:1281-1287, 2010
    • (2010) Eur Spine J , vol.19 , pp. 1281-1287
    • Fuentes, S.1    Blondel, B.2    Metellus, P.3    Gaudart, J.4    Adetchessi, T.5    Dufour, H.6
  • 15
    • 0043165850 scopus 로고
    • Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty
    • Fr
    • Galibert P, Deramond H, Rosat P, Le Gars D: [Preliminary note on the treatment of vertebral angioma by percutaneous acrylic vertebroplasty.] Neurochirurgie 33:166-168, 1987 (Fr
    • (1987) Neurochirurgie , vol.33 , pp. 166-168
    • Galibert, P.1    Deramond, H.2    Rosat, P.3    Le Gars, D.4
  • 16
    • 33748339778 scopus 로고    scopus 로고
    • Balloon kyphoplasty for symptomatic vertebral body compression fractures results in rapid, significant, and sustained improvements in back pain, function, and quality of life for elderly patients
    • Garfin SR, Buckley RA, Ledlie J: Balloon kyphoplasty for symptomatic vertebral body compression fractures results in rapid, significant, and sustained improvements in back pain, function, and quality of life for elderly patients. Spine (Phila Pa 1976) 31:2213-2220, 2006
    • (2006) Spine (Phila Pa 1976) , vol.31 , pp. 2213-2220
    • Garfin, S.R.1    Buckley, R.A.2    Ledlie, J.3
  • 17
    • 0035879089 scopus 로고    scopus 로고
    • New technologies in spine: Kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures
    • Garfin SR, Yuan HA, Reiley MA: New technologies in spine: kyphoplasty and vertebroplasty for the treatment of painful osteoporotic compression fractures. Spine (Phila Pa 1976) 26:1511-1515, 2001
    • (2001) Spine (Phila Pa 1976) , vol.26 , pp. 1511-1515
    • Garfin, S.R.1    Yuan, H.A.2    Reiley, M.A.3
  • 19
    • 12144266672 scopus 로고    scopus 로고
    • Primary and secondary osteoporosis' incidence of subsequent vertebral compression fractures after kyphoplasty
    • Harrop JS, Prpa B, Reinhardt MK, Lieberman I: Primary and secondary osteoporosis' incidence of subsequent vertebral compression fractures after kyphoplasty. Spine (Phila Pa 1976) 29:2120-2125, 2004
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 2120-2125
    • Harrop, J.S.1    Prpa, B.2    Reinhardt, M.K.3    Lieberman, I.4
  • 20
    • 22244489660 scopus 로고    scopus 로고
    • Long-term morbidity and mortality after a clinically diagnosed vertebral fracture in the elderly - A 12- and 22-year follow-up of 257 patients
    • Hasserius R, Karlsson MK, Jónsson B, Redlund-Johnell I, Johnell O: Long-term morbidity and mortality after a clinically diagnosed vertebral fracture in the elderly - a 12- and 22-year follow-up of 257 patients. Calcif Tissue Int 76:235- 242, 2005
    • (2005) Calcif Tissue Int , vol.76 , pp. 235-242
    • Hasserius, R.1    Karlsson, M.K.2    Jónsson, B.3    Redlund-Johnell, I.4    Johnell, O.5
  • 21
    • 0035054442 scopus 로고    scopus 로고
    • Augmentation of mechanical properties in osteoporotic vertebral bones - A biomechanical investigation of vertebroplasty efficacy with different bone cements
    • Heini PF, Berlemann U, Kaufmann M, Lippuner K, Fankhauser C, van Landuyt P: Augmentation of mechanical properties in osteoporotic vertebral bones - a biomechanical investigation of vertebroplasty efficacy with different bone cements. Eur Spine J 10:164-171, 2001
    • (2001) Eur Spine J , vol.10 , pp. 164-171
    • Heini, P.F.1    Berlemann, U.2    Kaufmann, M.3    Lippuner, K.4    Fankhauser, C.5    Van Landuyt, P.6
  • 22
    • 60349086391 scopus 로고    scopus 로고
    • Recollapse of previous vertebral compression fracture after percutaneous vertebroplasty
    • Heo DH, Chin DK, Yoon YS, Kuh SU: Recollapse of previous vertebral compression fracture after percutaneous vertebroplasty. Osteoporos Int 20:473-480, 2009
    • (2009) Osteoporos Int , vol.20 , pp. 473-480
    • Heo, D.H.1    Chin, D.K.2    Yoon, Y.S.3    Kuh, S.U.4
  • 23
    • 33748086788 scopus 로고    scopus 로고
    • Vertebroplasty and kyphoplasty: A systematic review of 69 clinical studies
    • Hulme PA, Krebs J, Ferguson SJ, Berlemann U: Vertebroplasty and kyphoplasty: a systematic review of 69 clinical studies. Spine (Phila Pa 1976) 31:1983-2001, 2006
    • (2006) Spine (Phila Pa 1976) , vol.31 , pp. 1983-2001
    • Hulme, P.A.1    Krebs, J.2    Ferguson, S.J.3    Berlemann, U.4
  • 24
    • 0033766668 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty in the treatment of osteoporotic compression fractures
    • Jensen ME, Dion JE: Percutaneous vertebroplasty in the treatment of osteoporotic compression fractures. Neuroimaging Clin N Am 10:547-568, 2000
    • (2000) Neuroimaging Clin N Am , vol.10 , pp. 547-568
    • Jensen, M.E.1    Dion, J.E.2
  • 25
    • 0031545893 scopus 로고    scopus 로고
    • Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: Technical aspects
    • Jensen ME, Evans AJ, Mathis JM, Kallmes DF, Cloft HJ, Dion JE: Percutaneous polymethylmethacrylate vertebroplasty in the treatment of osteoporotic vertebral body compression fractures: technical aspects. AJNR Am J Neuroradiol 18:1897-1904, 1997
    • (1997) AJNR Am J Neuroradiol , vol.18 , pp. 1897-1904
    • Jensen, M.E.1    Evans, A.J.2    Mathis, J.M.3    Kallmes, D.F.4    Cloft, H.J.5    Dion, J.E.6
  • 27
    • 85088743512 scopus 로고    scopus 로고
    • Erratum in
    • Erratum in N Engl J Med 366:970, 2012
    • (2012) N Engl J Med , vol.366 , pp. 970
  • 28
    • 78650928717 scopus 로고    scopus 로고
    • Minimally invasive transforaminal lumbar interbody fusion: A review of techniques and outcomes
    • Karikari IO, Isaacs RE: Minimally invasive transforaminal lumbar interbody fusion: a review of techniques and outcomes. Spine (Phila Pa 1976) 35 (26 Suppl):S294-S301, 2010
    • (2010) Spine (Phila Pa 1976) , vol.35 , Issue.26 SUPPL.
    • Karikari, I.O.1    Isaacs, R.E.2
  • 29
    • 84859484010 scopus 로고    scopus 로고
    • Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty
    • Kim MH, Lee AS, Min SH, Yoon SH: Risk factors of new compression fractures in adjacent vertebrae after percutaneous vertebroplasty. Asian Spine J 5:180-187, 2011
    • (2011) Asian Spine J , vol.5 , pp. 180-187
    • Kim, M.H.1    Lee, A.S.2    Min, S.H.3    Yoon, S.H.4
  • 30
    • 78349307007 scopus 로고    scopus 로고
    • Recompression of vertebral bodies after balloon kyphoplasty for vertebral compression fractures - Preliminary report
    • Kim YY, Park CG, Rhyu KW: Recompression of vertebral bodies after balloon kyphoplasty for vertebral compression fractures - preliminary report. J Korean Spine Surg 16:89- 94, 2009
    • (2009) J Korean Spine Surg , vol.16 , pp. 89-94
    • Kim, Y.Y.1    Park, C.G.2    Rhyu, K.W.3
  • 31
    • 78349313677 scopus 로고    scopus 로고
    • Recompression of vertebral body after balloon kyphoplasty for osteoporotic vertebral compression fracture
    • Kim YY, Rhyu KW: Recompression of vertebral body after balloon kyphoplasty for osteoporotic vertebral compression fracture. Eur Spine J 19:1907-1912, 2010
    • (2010) Eur Spine J , vol.19 , pp. 1907-1912
    • Kim, Y.Y.1    Rhyu, K.W.2
  • 33
    • 39649090067 scopus 로고    scopus 로고
    • Direct reduction of thoracolumbar burst fractures by means of balloon kyphoplasty with calcium phosphate and stabilization with pedicle-screw instrumentation and fusion
    • Korovessis P, Repantis T, Petsinis G, Iliopoulos P, Hadjipavlou A: Direct reduction of thoracolumbar burst fractures by means of balloon kyphoplasty with calcium phosphate and stabilization with pedicle-screw instrumentation and fusion. Spine (Phila Pa 1976) 33:E100-E108, 2008
    • (2008) Spine (Phila Pa 1976) , vol.33
    • Korovessis, P.1    Repantis, T.2    Petsinis, G.3    Iliopoulos, P.4    Hadjipavlou, A.5
  • 34
    • 48949091873 scopus 로고    scopus 로고
    • Evolution of bone mineral density after percutaneous kyphoplasty in fresh osteoporotic vertebral body fractures and adjacent vertebrae along with sagittal spine alignment
    • Korovessis P, Zacharatos S, Repantis T, Michael A, Karachalios D: Evolution of bone mineral density after percutaneous kyphoplasty in fresh osteoporotic vertebral body fractures and adjacent vertebrae along with sagittal spine alignment. J Spinal Disord Tech 21:293-298, 2008
    • (2008) J Spinal Disord Tech , vol.21 , pp. 293-298
    • Korovessis, P.1    Zacharatos, S.2    Repantis, T.3    Michael, A.4    Karachalios, D.5
  • 35
    • 33747354123 scopus 로고    scopus 로고
    • Recurrent fracture after vertebral kyphoplasty
    • Lavelle WF, Cheney R: Recurrent fracture after vertebral kyphoplasty. Spine J 6:488-493, 2006
    • (2006) Spine J , vol.6 , pp. 488-493
    • Lavelle, W.F.1    Cheney, R.2
  • 36
  • 37
    • 33645749139 scopus 로고    scopus 로고
    • Repeated fracture of a vertebral body after treatment with balloon kyphoplasty. Case illustration
    • Leslie-Mazwi T, Deen HG: Repeated fracture of a vertebral body after treatment with balloon kyphoplasty. Case illustration. J Neurosurg Spine 4:270, 2006
    • (2006) J Neurosurg Spine , vol.4 , pp. 270
    • Leslie-Mazwi, T.1    Deen, H.G.2
  • 38
    • 0035879322 scopus 로고    scopus 로고
    • Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures
    • Lieberman IH, Dudeney S, Reinhardt MK, Bell G: Initial outcome and efficacy of "kyphoplasty" in the treatment of painful osteoporotic vertebral compression fractures. Spine (Phila Pa 1976) 26:1631-1638, 2001
    • (2001) Spine (Phila Pa 1976) , vol.26 , pp. 1631-1638
    • Lieberman, I.H.1    Dudeney, S.2    Reinhardt, M.K.3    Bell, G.4
  • 39
    • 0035879306 scopus 로고    scopus 로고
    • Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty
    • Liebschner MA, Rosenberg WS, Keaveny TM: Effects of bone cement volume and distribution on vertebral stiffness after vertebroplasty. Spine (Phila Pa 1976) 26:1547-1554, 2001
    • (2001) Spine (Phila Pa 1976) , vol.26 , pp. 1547-1554
    • Liebschner, M.A.1    Rosenberg, W.S.2    Keaveny, T.M.3
  • 41
    • 0036741781 scopus 로고    scopus 로고
    • Prospective evaluation of pain relief in 100 patients undergoing percutaneous vertebroplasty: Results and follow-up
    • McGraw JK, Lippert JA, Minkus KD, Rami PM, Davis TM, Budzik RF: Prospective evaluation of pain relief in 100 patients undergoing percutaneous vertebroplasty: results and follow-up. J Vasc Interv Radiol 13:883-886, 2002
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 883-886
    • McGraw, J.K.1    Lippert, J.A.2    Minkus, K.D.3    Rami, P.M.4    Davis, T.M.5    Budzik, R.F.6
  • 43
    • 0032521419 scopus 로고    scopus 로고
    • Reinforcement of thoracolumbar burst fractures with calcium phosphate cement. A biomechanical study
    • Mermelstein LE, McLain RF, Yerby SA: Reinforcement of thoracolumbar burst fractures with calcium phosphate cement. A biomechanical study. Spine (Phila Pa 1976) 23:664- 671, 1998
    • (1998) Spine (Phila Pa 1976) , vol.23 , pp. 664-671
    • Mermelstein, L.E.1    McLain, R.F.2    Yerby, S.A.3
  • 44
    • 79951697659 scopus 로고    scopus 로고
    • Mini-open and minimally invasive transforaminal lumbar interbody fusion: Technique review
    • Meyer SA, Wu JC, Mummaneni PV: Mini-open and minimally invasive transforaminal lumbar interbody fusion: technique review. Semin Spine Surg 23:45-50, 2011
    • (2011) Semin Spine Surg , vol.23 , pp. 45-50
    • Meyer, S.A.1    Wu, J.C.2    Mummaneni, P.V.3
  • 45
    • 0034193916 scopus 로고    scopus 로고
    • Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: A consecutive 4 1/2-year series
    • Parker JW, Lane JR, Karaikovic EE, Gaines RW: Successful short-segment instrumentation and fusion for thoracolumbar spine fractures: a consecutive 4 1/2-year series. Spine (Phila Pa 1976) 25:1157-1170, 2000
    • (2000) Spine (Phila Pa 1976) , vol.25 , pp. 1157-1170
    • Parker, J.W.1    Lane, J.R.2    Karaikovic, E.E.3    Gaines, R.W.4
  • 47
    • 33749503782 scopus 로고    scopus 로고
    • Incidence of adjacent vertebral fractures in patients treated with balloon kyphoplasty: Two years' prospective follow-up
    • Pflugmacher R, Schroeder RJ, Klostermann CK: Incidence of adjacent vertebral fractures in patients treated with balloon kyphoplasty: two years' prospective follow-up. Acta Radiol 47:830-840, 2006
    • (2006) Acta Radiol , vol.47 , pp. 830-840
    • Pflugmacher, R.1    Schroeder, R.J.2    Klostermann, C.K.3
  • 48
    • 0141780978 scopus 로고    scopus 로고
    • Early radiographic and clinical results of balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures
    • Phillips FM, Ho E, Campbell-Hupp M, McNally T, Todd Wetzel F, Gupta P: Early radiographic and clinical results of balloon kyphoplasty for the treatment of osteoporotic vertebral compression fractures. Spine (Phila Pa 1976) 28:2260-2267, 2003
    • (2003) Spine (Phila Pa 1976) , vol.28 , pp. 2260-2267
    • Phillips, F.M.1    Ho, E.2    Campbell-Hupp, M.3    McNally, T.4    Todd Wetzel, F.5    Gupta, P.6
  • 49
    • 31844454303 scopus 로고    scopus 로고
    • Prospective measurement of function and pain in patients with non-neoplastic compression fractures treated with vertebroplasty
    • Prather H, Van Dillen L, Metzler JP, Riew KD, Gilula LA: Prospective measurement of function and pain in patients with non-neoplastic compression fractures treated with vertebroplasty. J Bone Joint Surg Am 88:334-341, 2006
    • (2006) J Bone Joint Surg Am , vol.88 , pp. 334-341
    • Prather, H.1    Van Dillen, L.2    Metzler, J.P.3    Riew, K.D.4    Gilula, L.A.5
  • 50
    • 84862850441 scopus 로고    scopus 로고
    • Risk factors predicting the new symptomatic vertebral compression fractures after percutaneous vertebroplasty or kyphoplasty
    • Rho YJ, Choe WJ, Chun YI: Risk factors predicting the new symptomatic vertebral compression fractures after percutaneous vertebroplasty or kyphoplasty. Eur Spine J 21:905-911, 2012
    • (2012) Eur Spine J , vol.21 , pp. 905-911
    • Rho, Y.J.1    Choe, W.J.2    Chun, Y.I.3
  • 52
    • 21244447553 scopus 로고    scopus 로고
    • Balloon vertebroplasty in combination with pedicle screw instrumentation: A novel technique to treat thoracic and lumbar burst fractures
    • Verlaan JJ, Dhert WJ, Verbout AJ, Oner FC: Balloon vertebroplasty in combination with pedicle screw instrumentation: a novel technique to treat thoracic and lumbar burst fractures. Spine (Phila Pa 1976) 30:E73-E79, 2005
    • (2005) Spine (Phila Pa 1976) , vol.30
    • Verlaan, J.J.1    Dhert, W.J.2    Verbout, A.J.3    Oner, F.C.4
  • 53
    • 33747464640 scopus 로고    scopus 로고
    • Prospective clinical follow-up after percutaneous vertebroplasty in patients with painful osteoporotic vertebral compression fractures
    • Voormolen MH, Lohle PN, Lampmann LE, van den Wildenberg W, Juttmann JR, Diekerhof CH, et al: Prospective clinical follow-up after percutaneous vertebroplasty in patients with painful osteoporotic vertebral compression fractures. J Vasc Interv Radiol 17:1313-1320, 2006
    • (2006) J Vasc Interv Radiol , vol.17 , pp. 1313-1320
    • Voormolen, M.H.1    Lohle, P.N.2    Lampmann, L.E.3    Van Den Wildenberg, W.4    Juttmann, J.R.5    Diekerhof, C.H.6
  • 55
    • 0036169233 scopus 로고    scopus 로고
    • Percutaneous vertebroplasty for osteoporotic compression fractures: Quantitative prospective evaluation of long-term outcomes
    • Zoarski GH, Snow P, Olan WJ, Stallmeyer MJ, Dick BW, Hebel JR, et al: Percutaneous vertebroplasty for osteoporotic compression fractures: quantitative prospective evaluation of long-term outcomes. J Vasc Interv Radiol 13:139-148, 2002
    • (2002) J Vasc Interv Radiol , vol.13 , pp. 139-148
    • Zoarski, G.H.1    Snow, P.2    Olan, W.J.3    Stallmeyer, M.J.4    Dick, B.W.5    Hebel, J.R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.