메뉴 건너뛰기




Volumn 114, Issue 8, 2013, Pages 1094-1107

Automated open flow respirometry in continuous and long-term measurements: Design and principles

Author keywords

Gas drying; Indirect calorimetry; Metabolic rate; Oxygen consumption; Software algorithm

Indexed keywords

AIR; ALGORITHM; ANIMAL; ARTICLE; BIOLOGICAL MODEL; BREATHING; CALIBRATION; CALORIMETRY; COMPUTER PROGRAM; ENERGY METABOLISM; EQUIPMENT; EQUIPMENT DESIGN; HIBERNATION; HUMIDITY; LABORATORY AUTOMATION; LUNG GAS EXCHANGE; METHODOLOGY; OXYGEN CONSUMPTION; REPRODUCIBILITY; STANDARD; TIME;

EID: 84878525020     PISSN: 87507587     EISSN: 15221601     Source Type: Journal    
DOI: 10.1152/japplphysiol.01494.2012     Document Type: Article
Times cited : (19)

References (32)
  • 1
    • 0003257622 scopus 로고
    • Time-resolved respirometry: Equations for the simultaneous measurement of all respiratory gases and the calibration of oxygen consumption using variable inert gas flow rates
    • Bakken GS. Time-resolved respirometry: equations for the simultaneous measurement of all respiratory gases and the calibration of oxygen consumption using variable inert gas flow rates. J Therm Biol 16:3313-315, 1991.
    • (1991) J Therm Biol , vol.16 , pp. 3313-3315
    • Bakken, G.S.1
  • 2
    • 0002274684 scopus 로고
    • Instantaneous measurement of oxygen consumption during pre-flight warm-up and post-flight cooling in Sphingid and Saturniid moths
    • Bartholomew GA, Vleck D, Vleck CM. Instantaneous measurement of oxygen consumption during pre-flight warm-up and post-flight cooling in Sphingid and Saturniid moths. J Exp Biol 90:17-32, 1981.
    • (1981) J Exp Biol , vol.90 , pp. 17-32
    • Bartholomew, G.A.1    Vleck, D.2    Vleck, C.M.3
  • 5
    • 0001634920 scopus 로고
    • Use of the Pauling oxygen analyzer for measurement of oxygen consumption of animals in open-circuit systems and in short lag, closed-circuit apparatus
    • Depocas F, Hart JS. Use of the Pauling oxygen analyzer for measurement of oxygen consumption of animals in open-circuit systems and in short lag, closed-circuit apparatus. J Appl Physiol 10:388-392, 1957.
    • (1957) J Appl Physiol , vol.10 , pp. 388-392
    • Depocas, F.1    Hart, J.S.2
  • 6
    • 0002834878 scopus 로고
    • A barometric method for measuring ventilation in newborn infants
    • Drorbaugh JE, Fenn WO. A barometric method for measuring ventilation in newborn infants. Pediatrics 16:81-86, 1955.
    • (1955) Pediatrics , vol.16 , pp. 81-86
    • Drorbaugh, J.E.1    Fenn, W.O.2
  • 10
    • 0015385440 scopus 로고
    • Determination of oxygen consumption using the paramagnetic oxygen analyzer
    • Hill RW. Determination of oxygen consumption using the paramagnetic oxygen analyzer. J Appl Physiol 33:261-263, 1972.
    • (1972) J Appl Physiol , vol.33 , pp. 261-263
    • Hill, R.W.1
  • 11
    • 70349773842 scopus 로고    scopus 로고
    • Energetics of arousal episodes in hibernating arctic ground squirrels
    • Karpovich SA, Toien O, Buck CL, Barnes BM. Energetics of arousal episodes in hibernating arctic ground squirrels. J Comp Physiol B 179:691-700, 2009.
    • (2009) J Comp Physiol B , vol.179 , pp. 691-700
    • Karpovich, S.A.1    Toien, O.2    Buck, C.L.3    Barnes, B.M.4
  • 13
    • 0030512501 scopus 로고    scopus 로고
    • Measuring energy metabolism with open-flow respirometric systems: Which design to choose?
    • Koteja P. Measuring energy metabolism with open-flow respirometric systems: which design to choose? Funct Ecol 10:675-677, 1996.
    • (1996) Funct Ecol , vol.10 , pp. 675-677
    • Koteja, P.1
  • 14
    • 0031083051 scopus 로고    scopus 로고
    • Efficiency and temperature dependence of water removal by membrane dryers
    • Leckrone KJ, Hayes JM. Efficiency and temperature dependence of water removal by membrane dryers. Anal Chem 69:911-918, 1997.
    • (1997) Anal Chem , vol.69 , pp. 911-918
    • Leckrone, K.J.1    Hayes, J.M.2
  • 16
    • 79251595333 scopus 로고    scopus 로고
    • Flow-through respirometry applied to chamber systems: Pros and cons, hints and tips
    • Lighton JRB, Halsey LG. Flow-through respirometry applied to chamber systems: pros and cons, hints and tips. Comp Biochem Physiol A Mol Integr Physiol 158:265-275, 2011.
    • (2011) Comp Biochem Physiol A Mol Integr Physiol , vol.158 , pp. 265-275
    • Lighton, J.R.B.1    Halsey, L.G.2
  • 17
    • 0015887965 scopus 로고
    • Validity of Haldane calculation for estimating respiratory gas exchange
    • Luft UC, Myhre LG, Loeppky JA. Validity of Haldane calculation for estimating respiratory gas exchange. J Appl Physiol 34:864-854, 1973.
    • (1973) J Appl Physiol , vol.34 , pp. 864-854
    • Luft, U.C.1    Myhre, L.G.2    Loeppky, J.A.3
  • 21
    • 0026229647 scopus 로고
    • MRATE: A Pascal program for on-line calculation of metabolic rate using wet gases
    • Nicol SC. MRATE: a Pascal program for on-line calculation of metabolic rate using wet gases. Comput Methods Programs Biomed 36:27-32, 1991.
    • (1991) Comput Methods Programs Biomed , vol.36 , pp. 27-32
    • Nicol, S.C.1
  • 22
    • 84878587975 scopus 로고    scopus 로고
    • Online
    • Perma Pure LLC. Effects of Temperature on Nafion Gas Dryers (Online). http://www.permapure.com/tech-notes/key-concepts/effects-of-temperatureonnafion- gas-dryers/?ind=science [2012].
    • (2012) Effects of Temperature on Nafion Gas Dryers
  • 24
    • 0002928238 scopus 로고
    • Data acquisition in thermal physiology: Measurements of shivering
    • Toien O. Data acquisition in thermal physiology: measurements of shivering. J Therm Biol 17:357-366, 1992.
    • (1992) J Therm Biol , vol.17 , pp. 357-366
    • Toien, O.1
  • 25
    • 79951824325 scopus 로고    scopus 로고
    • Hibernation in black bears: Independence of metabolic suppression from body temperature
    • Toien O, Blake J, Edgar DM, Grahn DA, Heller HC, Barnes BM. Hibernation in black bears: independence of metabolic suppression from body temperature. Science 331:906-909, 2011.
    • (2011) Science , vol.331 , pp. 906-909
    • Toien, O.1    Blake, J.2    Edgar, D.M.3    Grahn, D.A.4    Heller, H.C.5    Barnes, B.M.6
  • 26
    • 84878554528 scopus 로고    scopus 로고
    • Tylan instruction manual 900457001
    • Tylan, May, Appendix A. Billerica, MA: Mykrolis, 2003
    • Tylan. Tylan Instruction Manual 900457001, Rev. J, May 2003, Appendix A. Billerica, MA: Mykrolis, 2003.
    • (2003) Rev. J
  • 27
    • 0015878999 scopus 로고
    • Validation of opencircuit method for the determination of oxygen consumption
    • Wagner JA, Horwath SM, Dahms TE, Reed S. Validation of opencircuit method for the determination of oxygen consumption. J Appl Physiol 34:859-863, 1973.
    • (1973) J Appl Physiol , vol.34 , pp. 859-863
    • Wagner, J.A.1    Horwath, S.M.2    Dahms, T.E.3    Reed, S.4
  • 28
    • 33748783621 scopus 로고    scopus 로고
    • Respirometry: Anhydrous drierite equilibrates with carbon dioxide and increases washout times
    • DOI 10.1086/505994
    • White CR, Portugal SJ, Martin GR, Butler PJ. Respirometry: anhydrous Drierite equilibrates with carbon dioxide and increases washout times. Physiol Biochem Zool 79:977-980, 2006. (Pubitemid 44412221)
    • (2006) Physiological and Biochemical Zoology , vol.79 , Issue.5 , pp. 977-980
    • White, C.R.1    Portugal, S.J.2    Martin, G.R.3    Butler, P.J.4
  • 30
    • 0034779544 scopus 로고    scopus 로고
    • Design, calibration and calculation for flow-through respirometry systems
    • DOI 10.1071/ZO00057
    • Withers PC. Design, calibration and calculation for flow-through respirometry systems. Aust J Zool 49:445-461, 2001. (Pubitemid 33001817)
    • (2001) Australian Journal of Zoology , vol.49 , Issue.4 , pp. 445-461
    • Withers, P.C.1
  • 31
    • 0017351411 scopus 로고
    • 2, and evaporative water loss with a flow through mask
    • 2, and evaporative water loss with a flow-through mask. J Appl Physiol 42:120-123, 1977. (Pubitemid 8039925)
    • (1977) J Appl Physiol , vol.42 , Issue.1 , pp. 120-123
    • Withers, P.C.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.