메뉴 건너뛰기




Volumn 38, Issue SUPPL.36, 2006, Pages 557-561

Validation of a portable equine metabolic measurement system

Author keywords

Exercise; Horse; Oxygen uptake measurement; Portable metabolic system; Ventilation

Indexed keywords

EQUIDAE;

EID: 84878460086     PISSN: 04251644     EISSN: 20423306     Source Type: Journal    
DOI: 10.1111/j.2042-3306.2006.tb05604.x     Document Type: Article
Times cited : (27)

References (15)
  • 1
    • 0023675653 scopus 로고
    • Pulmonary mechanics during treadmill exercise in race ponies
    • Art, T. and Lekeux, P. (1988) Pulmonary mechanics during treadmill exercise in race ponies. Vet. Res. Comm. 12, 245-258.
    • (1988) Vet. Res. Comm. , vol.12 , pp. 245-258
    • Art, T.1    Lekeux, P.2
  • 2
    • 0031911821 scopus 로고    scopus 로고
    • Does an acute COPD crisis modify the cardiorespiratory and ventilatory adjustments to exercise in horses
    • Art, T., Duvivier, D. H., Votion, D., Anciaux, N., Vandenput, S., Bayly, W. M. and Lekeux, P. (1998) Does an acute COPD crisis modify the cardiorespiratory and ventilatory adjustments to exercise in horses J. appl. Physiol. 84, 845-852.
    • (1998) J. appl. Physiol. , vol.84 , pp. 845-852
    • Art, T.1    Duvivier, D.H.2    Votion, D.3    Anciaux, N.4    Vandenput, S.5    Bayly, W.M.6    Lekeux, P.7
  • 3
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland, J. M. and Altman D. G. (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet, 1, 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 4
    • 2942587139 scopus 로고    scopus 로고
    • Validation of the portable VmaxST system for oxygen-uptake measurement
    • Brehm, M. A., Harlaar, J. and Groepenhof, H. (2004) Validation of the portable VmaxST system for oxygen-uptake measurement. Gait Posture 20, 67-73.
    • (2004) Gait Posture , vol.20 , pp. 67-73
    • Brehm, M.A.1    Harlaar, J.2    Groepenhof, H.3
  • 6
    • 3343021881 scopus 로고    scopus 로고
    • Accuracy and reliability of a Cosmed K4B2 portable gas analysis System
    • Duffield, R., Dawson, B., Pinnington, H. C. and Wong, P. (2004) Accuracy and reliability of a Cosmed K4B2 portable gas analysis System. J. Sci. Med. Sport. 7, 11-22.
    • (2004) J. Sci. Med. Sport. , vol.7 , pp. 11-22
    • Duffield, R.1    Dawson, B.2    Pinnington, H.C.3    Wong, P.4
  • 7
    • 0006322504 scopus 로고
    • Energetics and performance
    • Eds: D. R. Hodgson and R. J. Rose, W. B. Saunders Company, Philadelphia
    • Eaton, M. D. (1994) Energetics and performance. In: The Athletic Horse: Principles and Practice of Equine Sports Medicine, Eds: D. R. Hodgson and R. J. Rose, W. B. Saunders Company, Philadelphia, pp 49-61.
    • (1994) The Athletic Horse: Principles and Practice of Equine Sports Medicine , pp. 49-61
    • Eaton, M.D.1
  • 8
    • 0037711917 scopus 로고    scopus 로고
    • Comparative analysis of the Cosmed Quark b2 and K4b2 gas analysis systems during submaximal exercise
    • Eisenmann, J. C., Brisko, N., Shadrick, D. and Welsh, S. (2003) Comparative analysis of the Cosmed Quark b2 and K4b2 gas analysis systems during submaximal exercise. J. Sports Med. Phys. Fitness 43, 150-155.
    • (2003) J. Sports Med. Phys. Fitness , vol.43 , pp. 150-155
    • Eisenmann, J.C.1    Brisko, N.2    Shadrick, D.3    Welsh, S.4
  • 9
    • 0030880253 scopus 로고    scopus 로고
    • The Cosmed K4 telemetry system as an accurate device for oxygen uptake measurements during exercise
    • Hausswirth, C., Bigard, A. X. and Le Chevalier, J. M. (1997) The Cosmed K4 telemetry system as an accurate device for oxygen uptake measurements during exercise. Int. J. Sports Med. 18, 449-453.
    • (1997) Int. J. Sports Med. , vol.18 , pp. 449-453
    • Hausswirth, C.1    Bigard, A.X.2    Le Chevalier, J.M.3
  • 11
    • 0141991322 scopus 로고    scopus 로고
    • Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer
    • Maiolo, C., Melchiorri, G., Iacopino, L., Masala, S. and de Lorenzo, A. (2003) Physical activity energy expenditure measured using a portable telemetric device in comparison with a mass spectrometer. Br. J. Sports Med. 37, 445-447.
    • (2003) Br. J. Sports Med. , vol.37 , pp. 445-447
    • Maiolo, C.1    Melchiorri, G.2    Iacopino, L.3    Masala, S.4    de Lorenzo, A.5
  • 14
    • 0038709497 scopus 로고    scopus 로고
    • A methodology to assess the accuracy of a portable metabolic system (VmaxST)
    • Prieur, F., Castells, J. and Denis, C. (2003) A methodology to assess the accuracy of a portable metabolic system (VmaxST). Med. Sci. Sports Exerc. 35, 879-885.
    • (2003) Med. Sci. Sports Exerc. , vol.35 , pp. 879-885
    • Prieur, F.1    Castells, J.2    Denis, C.3
  • 15
    • 0030799854 scopus 로고    scopus 로고
    • The validity of the telemetric system CORTEX X1 in the ventilatory and gas exchange measurement during exercise
    • Schulz, H., Helle, S. and Heck, H. (1997) The validity of the telemetric system CORTEX X1 in the ventilatory and gas exchange measurement during exercise. Int. J. sports Med. 18, 454-457.
    • (1997) Int. J. sports Med. , vol.18 , pp. 454-457
    • Schulz, H.1    Helle, S.2    Heck, H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.