메뉴 건너뛰기




Volumn 41, Issue 2, 2013, Pages 247-252

Metal allergy in patients with total hip replacement: A review

Author keywords

Allergic contact dermatitis; Co cr mo alloy; Corrosion products; Infection; Metal allergy; Metal ion concentration; Painful hip; Total hip replacement

Indexed keywords

ALLOY; CHROMIUM; COBALT; MOLYBDENUM; TITANIUM;

EID: 84878362141     PISSN: 03000605     EISSN: 14732300     Source Type: Journal    
DOI: 10.1177/0300060513476583     Document Type: Article
Times cited : (20)

References (46)
  • 1
    • 0036483749 scopus 로고    scopus 로고
    • Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: Factors affecting survivorship of acetabular and femoral components
    • Berry DJ, Harmsen WS, Cabanela ME, et al. Twenty-five-year survivorship of two thousand consecutive primary Charnley total hip replacements: factors affecting survivorship of acetabular and femoral components. J Bone Joint Surg Am 2002; 84: 171-177
    • (2002) J Bone Joint Surg Am , vol.84 , pp. 171-177
    • Berry, D.J.1    Harmsen, W.S.2    Cabanela, M.E.3
  • 2
    • 0035039969 scopus 로고    scopus 로고
    • Outcome after total hip arthroplasty: Part II. Disease-specific follow-up and the Swedish National Total Hip Arthroplasty Register
    • Söderman P, Malchau H, Herberts P, et al. Outcome after total hip arthroplasty: Part II. Disease-specific follow-up and the Swedish National Total Hip Arthroplasty Register. Acta Orthop Scand 2001; 72: 113-119
    • (2001) Acta Orthop Scand , vol.72 , pp. 113-119
    • Söderman, P.1    Malchau, H.2    Herberts, P.3
  • 3
    • 0033641059 scopus 로고    scopus 로고
    • Ultralow wear rates for rigid-on-rigid bearings in total hip replacements
    • Clarke IC, Good V, Williams P, et al. Ultralow wear rates for rigid-on-rigid bearings in total hip replacements. Proc Inst Mech Eng H 2000; 214: 331-347
    • (2000) Proc Inst Mech Eng H , vol.214 , pp. 331-347
    • Clarke, I.C.1    Good, V.2    Williams, P.3
  • 4
    • 0033775261 scopus 로고    scopus 로고
    • Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear
    • Clarke IC and Gustafson A. Clinical and hip simulator comparisons of ceramic-on-polyethylene and metal-on-polyethylene wear. Clin Orthop Relat Res 2000; 379: 34-40
    • (2000) Clin Orthop Relat Res , vol.379 , pp. 34-40
    • Clarke, I.C.1    Gustafson, A.2
  • 6
    • 56649097450 scopus 로고    scopus 로고
    • Presence of corrosion products and hypersensitivity- associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces
    • Huber M, Reinisch G, Trettenhahn G, et al. Presence of corrosion products and hypersensitivity- associated reactions in periprosthetic tissue after aseptic loosening of total hip replacements with metal bearing surfaces. Acta Biomater 2009; 5: 172-180
    • (2009) Acta Biomater , vol.5 , pp. 172-180
    • Huber, M.1    Reinisch, G.2    Trettenhahn, G.3
  • 7
    • 0004131205 scopus 로고
    • 2nd ed. Philadelphia: Lee & Febiger
    • Fisher AA. Contact Dermatitis, 2nd ed. Philadelphia: Lee & Febiger, 1973, pp.82-90
    • (1973) Contact Dermatitis , pp. 82-90
    • Fisher, A.A.1
  • 8
    • 9444243222 scopus 로고    scopus 로고
    • Metal ion release from metal implants
    • Hanawa T. Metal ion release from metal implants. Mater Sci Eng C Mater Biol Appl 2004; 24: 745-752
    • (2004) Mater Sci Eng C Mater Biol Appl , vol.24 , pp. 745-752
    • Hanawa, T.1
  • 9
    • 0022192425 scopus 로고
    • Podiatric metallurgy and the effects of implanted metals on living tissues
    • Jacobs AM and Oloff LM. Podiatric metallurgy and the effects of implanted metals on living tissues. Clin Podiatry 1985; 2: 121-141
    • (1985) Clin Podiatry , vol.2 , pp. 121-141
    • Jacobs, A.M.1    Oloff, L.M.2
  • 11
    • 0029997499 scopus 로고    scopus 로고
    • Immune response to synthetic materials
    • Sensitization of patients receiving orthopaedic implants
    • Merritt K and Rodrigo JJ. Immune response to synthetic materials. Sensitization of patients receiving orthopaedic implants. Clin Orthop Relat Res 1996; 326: 71-79
    • (1996) Clin Orthop Relat Res , vol.326 , pp. 71-79
    • Merritt, K.1    Rodrigo, J.J.2
  • 12
    • 0026001184 scopus 로고
    • Patch testing for allergic reactions to metals in orthopedic implants
    • Fisher AA. Patch testing for allergic reactions to metals in orthopedic implants. Cutis 1991; 48: 183-184
    • (1991) Cutis , vol.48 , pp. 183-184
    • Fisher, A.A.1
  • 13
    • 0017754035 scopus 로고
    • Titanium as a metal for implantation. Part 2: Biological properties and clinical applications
    • Williams DF. Titanium as a metal for implantation. Part 2: biological properties and clinical applications. J Med Eng Technol 1977; 1: 266-270
    • (1977) J Med Eng Technol , vol.1 , pp. 266-270
    • Williams, D.F.1
  • 14
    • 0027711698 scopus 로고
    • Biodeterioration and corrosion of metallic implants and prosthesis
    • [in Spanish, English abstract]
    • López GD. Biodeterioration and corrosion of metallic implants and prosthesis. Medicina (B Aires) 1993; 53: 260-274.[in Spanish, English abstract]
    • (1993) Medicina (B Aires) , vol.53 , pp. 260-274
    • López, G.D.1
  • 15
    • 0000784646 scopus 로고
    • Electrochemical behavior of titanium
    • Kelly EJ. Electrochemical behavior of titanium. Mod Aspects Electrochem 1982; 14: 319-424
    • (1982) Mod Aspects Electrochem , vol.14 , pp. 319-424
    • Kelly, E.J.1
  • 16
    • 0022650707 scopus 로고
    • Prevalence of contact allergy by sex, race, and age
    • Goh CL. Prevalence of contact allergy by sex, race, and age. Contact Dermatitis 1986; 14: 237-240
    • (1986) Contact Dermatitis , vol.14 , pp. 237-240
    • Goh, C.L.1
  • 17
    • 0016719878 scopus 로고
    • The frequency of contact dermatitis in North America 1972-74. North American Contact Dermatitis Group
    • Rudner EJ, Clendenning WE, Epstein E, et al. The frequency of contact dermatitis in North America 1972-74. North American Contact Dermatitis Group. Contact Dermatitis 1975; 1: 277-280
    • (1975) Contact Dermatitis , vol.1 , pp. 277-280
    • Rudner, E.J.1    Clendenning, W.E.2    Epstein, E.3
  • 19
    • 0037233869 scopus 로고    scopus 로고
    • Metal-on-metal versus polyethylene in hip arthroplasty: A randomized clinical trial
    • MacDonald SJ, McCalden RW, Chess DG, et al. Metal-on-metal versus polyethylene in hip arthroplasty: a randomized clinical trial. Clin Orthop Relat Res 2003; 406: 282-296
    • (2003) Clin Orthop Relat Res , vol.406 , pp. 282-296
    • Macdonald, S.J.1    McCalden, R.W.2    Chess, D.G.3
  • 20
    • 33750363656 scopus 로고    scopus 로고
    • Hip implants - paper IV - ion concentrations
    • Sargeant A and Goswami T. Hip implants - paper IV - ion concentrations. Materials & Design 2007; 28: 155-171
    • (2007) Materials & Design , vol.28 , pp. 155-171
    • Sargeant, A.1    Goswami, T.2
  • 21
    • 0031864958 scopus 로고
    • In vivo corrosion of 316L stainless-steel hip implants: Morphology and elemental compositions of corrosion products
    • Walczak J, Shahgaldi F and Heatley F. In vivo corrosion of 316L stainless-steel hip implants: morphology and elemental compositions of corrosion products. Biomaterials 1988; 19: 229-237
    • (1988) Biomaterials , vol.19 , pp. 229-237
    • Walczak, J.1    Shahgaldi, F.2    Heatley, F.3
  • 22
    • 0021346530 scopus 로고
    • Nickel and chromium content of selected human organs and body fluids
    • [in German, English abstract]
    • Zober A, Kick K, Schaller KH, et al. Nickel and chromium content of selected human organs and body fluids. Zentralbl Bakteriol Mikrobiol Hyg B 1984; 179: 80-95.[in German, English abstract]
    • (1984) Zentralbl Bakteriol Mikrobiol Hyg B , vol.179 , pp. 80-95
    • Zober, A.1    Kick, K.2    Schaller, K.H.3
  • 23
    • 0032732571 scopus 로고    scopus 로고
    • Blood chromium determination in assessing reference values in an unexposed Mediterranean population
    • Torra M, Rodamilans M, Corbella J, et al. Blood chromium determination in assessing reference values in an unexposed Mediterranean population. Bio Trace Elem Res 1999; 70: 183-189
    • (1999) Bio Trace Elem Res , vol.70 , pp. 183-189
    • Torra, M.1    Rodamilans, M.2    Corbella, J.3
  • 24
    • 0030881756 scopus 로고    scopus 로고
    • Toxic trace element reference levels in blood and urine: Influence of gender and lifestyle factors
    • Kristiansen J, Christenson JM, Iversen BS, et al. Toxic trace element reference levels in blood and urine: influence of gender and lifestyle factors. Sci Total Environ 1997; 204: 147-160
    • (1997) Sci Total Environ , vol.204 , pp. 147-160
    • Kristiansen, J.1    Christenson, J.M.2    Iversen, B.S.3
  • 26
    • 0034802505 scopus 로고    scopus 로고
    • Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation
    • Hallab NJ, Mikecz C, Vermes C, et al. Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation. Mol Cell Biochem 2001; 222: 127-136
    • (2001) Mol Cell Biochem , vol.222 , pp. 127-136
    • Hallab, N.J.1    Mikecz, C.2    Vermes, C.3
  • 27
    • 0027363019 scopus 로고
    • Cobalt determination in serum and urine by electrothermal atomic absorption spectrometry
    • Baruthio F and Pierre F. Cobalt determination in serum and urine by electrothermal atomic absorption spectrometry. Bio Trace Elem Res 1993; 39: 21-31
    • (1993) Bio Trace Elem Res , vol.39 , pp. 21-31
    • Baruthio, F.1    Pierre, F.2
  • 28
    • 0028229360 scopus 로고
    • Tentative reference values for nickel concentrations in human serum, plasma, blood, and urine: Evaluation according to the TRACY protocol
    • Templeton DM, Sunderman Jr FW and Herber RF. Tentative reference values for nickel concentrations in human serum, plasma, blood, and urine: evaluation according to the TRACY protocol. Sci Total Environ 1994; 148: 243-251
    • (1994) Sci Total Environ , vol.148 , pp. 243-251
    • Templeton, D.M.1    Sunderman Jr., F.W.2    Herber, R.F.3
  • 29
    • 0033372378 scopus 로고    scopus 로고
    • Increased blood cobalt and chromium after total hip replacement
    • Schaffer AW, Pilger A, Engelhardt C, et al. Increased blood cobalt and chromium after total hip replacement. J Toxicol Clin Toxicol 1999; 37: 839-844
    • (1999) J Toxicol Clin Toxicol , vol.37 , pp. 839-844
    • Schaffer, A.W.1    Pilger, A.2    Engelhardt, C.3
  • 30
    • 0032175733 scopus 로고    scopus 로고
    • The effects of metal corrosion debris on immune system cells
    • [in English, Italian]
    • Donati ME, Savarino L, Granchi D, et al. The effects of metal corrosion debris on immune system cells. Chir Organi Mov 1998; 83: 387-393.[in English, Italian]
    • (1998) Chir Organi Mov , vol.83 , pp. 387-393
    • Donati, M.E.1    Savarino, L.2    Granchi, D.3
  • 31
    • 0019451312 scopus 로고
    • Cutaneous complications of orthopedic implants
    • A two-year prospective study
    • Kubba R, Taylor JS and Marks KF. Cutaneous complications of orthopedic implants. A two-year prospective study. Arch Dermatol 1981; 117: 554-560
    • (1981) Arch Dermatol , vol.117 , pp. 554-560
    • Kubba, R.1    Taylor, J.S.2    Marks, K.F.3
  • 32
    • 79952408954 scopus 로고    scopus 로고
    • Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery
    • Thyssen JP, Menné T, Schalock PC, et al. Pragmatic approach to the clinical work-up of patients with putative allergic disease to metallic orthopaedic implants before and after surgery. Br J Dermatology 2011; 164: 473-478
    • (2011) Br J Dermatology , vol.164 , pp. 473-478
    • Thyssen, J.P.1    Menné, T.2    Schalock, P.C.3
  • 33
    • 0015610070 scopus 로고
    • An allergic reaction after internal fixation of a fracture using a Vitallium plate
    • Symeonides PP, Paschaloglou C and Papageorgiou S. An allergic reaction after internal fixation of a fracture using a Vitallium plate. J Allergy Clin Immunol 1973; 51: 251-252
    • (1973) J Allergy Clin Immunol , vol.51 , pp. 251-252
    • Symeonides, P.P.1    Paschaloglou, C.2    Papageorgiou, S.3
  • 34
    • 0017924249 scopus 로고
    • Dermatosis caused by bone graft material (author's transl)
    • [in French, English abstract]
    • Bazex A, Parant M, Bazex J, et al. Dermatosis caused by bone graft material (author's transl). Ann Dermatol Venereol 1978; 105: 9-15.[in French, English abstract]
    • (1978) Ann Dermatol Venereol , vol.105 , pp. 9-15
    • Bazex, A.1    Parant, M.2    Bazex, J.3
  • 35
    • 4143104143 scopus 로고
    • Nickel sensitivity resembling bullous pemphigoid
    • Kubba R and Champion RH. Nickel sensitivity resembling bullous pemphigoid. Br J Dermatol 1975; 93(suppl 11): 41-43
    • (1975) Br J Dermatol , vol.93 , Issue.SUPPL. 11 , pp. 41-43
    • Kubba, R.1    Champion, R.H.2
  • 36
    • 0022416478 scopus 로고
    • Interrelationship of nickel and cobalt contact sensitization
    • Lammintausta K, Pitkänen OP, Kalimo K, et al. Interrelationship of nickel and cobalt contact sensitization. Contact Dermatitis 1985; 13: 148-152
    • (1985) Contact Dermatitis , vol.13 , pp. 148-152
    • Lammintausta, K.1    Pitkänen, O.P.2    Kalimo, K.3
  • 37
    • 0018866890 scopus 로고
    • Metal allergy and the surgical patient
    • Mayor MB, Merritt K and Brown SA. Metal allergy and the surgical patient. Am J Surg 1980; 139: 477-479
    • (1980) Am J Surg , vol.139 , pp. 477-479
    • Mayor, M.B.1    Merritt, K.2    Brown, S.A.3
  • 38
    • 0018949020 scopus 로고
    • Intolerance to the products of wear of total hip prostheses. Anatomopathological and immunological study of 30 cases
    • [in French; authors' translation]
    • Langlais F, Postel M, Berry JP, et al. Intolerance to the products of wear of total hip prostheses. Anatomopathological and immunological study of 30 cases. Int Orthop 1980; 4: 145-153.[in French; authors' translation]
    • (1980) Int Orthop , vol.4 , pp. 145-153
    • Langlais, F.1    Postel, M.2    Berry, J.P.3
  • 39
    • 4444313276 scopus 로고    scopus 로고
    • Screening for symptomatic metal sensitivity: A prospective study of 92 patients undergoing total knee arthroplasty
    • Niki Y, Matsumoto M, Otani T, et al. Screening for symptomatic metal sensitivity: a prospective study of 92 patients undergoing total knee arthroplasty. Biomaterials 2005; 26: 1019-1026
    • (2005) Biomaterials , vol.26 , pp. 1019-1026
    • Niki, Y.1    Matsumoto, M.2    Otani, T.3
  • 40
    • 84864124341 scopus 로고    scopus 로고
    • Management of periprosthetic joint infection: The current knowledge. AAOS exhibit selection
    • Parvizi J, Adeli B, Zmistowski B, et al. Management of periprosthetic joint infection: the current knowledge. AAOS exhibit selection. J Bone Joint Surg Am 2012; 94: e104
    • (2012) J Bone Joint Surg Am , vol.94
    • Parvizi, J.1    Adeli, B.2    Zmistowski, B.3
  • 41
    • 0017596536 scopus 로고    scopus 로고
    • Sensitivity to metals as a possible cause of sterile loosening after cobalt-chromium total hip-replacement arthroplasty
    • Brown GC, Lockshin MD, Salvati EA, et al. Sensitivity to metals as a possible cause of sterile loosening after cobalt-chromium total hip-replacement arthroplasty. J Bone Joint Surg 1997; 59: 164-168
    • (1997) J Bone Joint Surg , vol.59 , pp. 164-168
    • Brown, G.C.1    Lockshin, M.D.2    Salvati, E.A.3
  • 42
    • 0029946492 scopus 로고    scopus 로고
    • Tc-99m stannous colloid-labelled leukocyte scintigraphy in the evaluation of the painful arthroplasty
    • Chik KK, Magee MA, Bruce WJ, et al. Tc-99m stannous colloid-labelled leukocyte scintigraphy in the evaluation of the painful arthroplasty. Clin Nucl Med 1996; 21: 838-843
    • (1996) Clin Nucl Med , vol.21 , pp. 838-843
    • Chik, K.K.1    Magee, M.A.2    Bruce, W.J.3
  • 43
    • 74249093657 scopus 로고    scopus 로고
    • Infection or allergy in the painful metal-onmetal total hip arthroplasty?
    • Biant LC, Bruce WJ, van der Wall H, et al. Infection or allergy in the painful metal-onmetal total hip arthroplasty? J Arthroplasty 2010; 25: 334.e11-334.e16
    • (2010) J Arthroplasty , vol.25
    • Biant, L.C.1    Bruce, W.J.2    van der Wall, H.3
  • 44
    • 67649546308 scopus 로고    scopus 로고
    • Patch-test results of the North American Contact Dermatitis Group 2005-2006
    • Zug KA, Warshaw EM, Fowler Jr JF, et al. Patch-test results of the North American Contact Dermatitis Group 2005-2006. Dermatitis 2009; 20: 149-160
    • (2009) Dermatitis , vol.20 , pp. 149-160
    • Zug, K.A.1    Warshaw, E.M.2    Fowler Jr., J.F.3
  • 45
    • 84874828152 scopus 로고    scopus 로고
    • Metal allergy and systemic contact dermatitis: An overview
    • 2012
    • Yoshihisa Y and Shimizu T. Metal allergy and systemic contact dermatitis: an overview. Dermatol Res Pract 2012; 2012: 749561
    • (2012) Dermatol Res Pract , pp. 749561
    • Yoshihisa, Y.1    Shimizu, T.2
  • 46
    • 0018890809 scopus 로고
    • Metal sensitivity in patients with metalto-plastic total hip arthroplasties
    • Carlsson AS, Magnusson B and Möller H. Metal sensitivity in patients with metalto-plastic total hip arthroplasties. Acta Orthop Scand 1980; 51: 57-62.
    • (1980) Acta Orthop Scand , vol.51 , pp. 57-62
    • Carlsson, A.S.1    Magnusson, B.2    Möller, M.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.