-
1
-
-
0036087258
-
Clinical review: Complications and risk factors of peripheral arterial catheters for haemodynamic monitoring in anaesthesia and intensive care medicine
-
10.1186/cc1489
-
Scheer BV, Perel A, Pfeiffer UJ. Clinical review: complications and risk factors of peripheral arterial catheters for haemodynamic monitoring in anaesthesia and intensive care medicine. Crit Care. 2002;6:198-204.
-
(2002)
Crit Care
, vol.6
, pp. 198-204
-
-
Scheer, B.V.1
Perel, A.2
Pfeiffer, U.J.3
-
2
-
-
0027158394
-
Delayed ischaemia of the hand necessitating amputation after radial artery cannulation
-
8467546 10.1007/BF03037036 1:STN:280:DyaK3s3itlartw%3D%3D
-
Mangar D, Laborde RS, Vu DN. Delayed ischaemia of the hand necessitating amputation after radial artery cannulation. Can J Anaesth. 1993;40:247-50.
-
(1993)
Can J Anaesth
, vol.40
, pp. 247-250
-
-
Mangar, D.1
Laborde, R.S.2
Vu, D.N.3
-
3
-
-
0037323897
-
Use of ultrasound guidance in the insertion of radial artery catheters
-
12576955 10.1097/01.CCM.0000050452.17304.2F
-
Levin PD, Sheinin O, Gozal Y. Use of ultrasound guidance in the insertion of radial artery catheters. Crit Care Med. 2003;31:481-4.
-
(2003)
Crit Care Med
, vol.31
, pp. 481-484
-
-
Levin, P.D.1
Sheinin, O.2
Gozal, Y.3
-
4
-
-
0036339456
-
Ultrasound guidance versus the landmark technique for the placement of central venous catheters in the emergency department
-
12153885 10.1111/j.1553-2712.2002.tb02168.x
-
Miller AH, Roth BA, Mills TJ, et al. Ultrasound guidance versus the landmark technique for the placement of central venous catheters in the emergency department. Acad Emerg Med. 2002;9:800-5.
-
(2002)
Acad Emerg Med
, vol.9
, pp. 800-805
-
-
Miller, A.H.1
Roth, B.A.2
Mills, T.J.3
-
5
-
-
79952222741
-
Ultrasound- guided catheterization of the radial artery: A systematic review and meta-analysis of randomized controlled trials
-
20724734 10.1378/chest.10-0919
-
Shiloh AL, Savel RH, Paulin LM, et al. Ultrasound- guided catheterization of the radial artery: a systematic review and meta-analysis of randomized controlled trials. Chest. 2011;139:524-9.
-
(2011)
Chest
, vol.139
, pp. 524-529
-
-
Shiloh, A.L.1
Savel, R.H.2
Paulin, L.M.3
-
6
-
-
33751221585
-
A prospective comparison of ultrasound-guided and blindly placed radial arterial catheters
-
17079789 10.1111/j.1553-2712.2006.tb00289.x
-
Shiver S, Blaivas M, Lyon M. A prospective comparison of ultrasound-guided and blindly placed radial arterial catheters. Acad Emerg Med. 2006;13(12):1275-9.
-
(2006)
Acad Emerg Med
, vol.13
, Issue.12
, pp. 1275-1279
-
-
Shiver, S.1
Blaivas, M.2
Lyon, M.3
-
7
-
-
0348014436
-
Short- axis versus long-axis approaches for teaching ultrasound- guided vascular access on a new inanimate model
-
14644780 10.1111/j.1553-2712.2003.tb00002.x
-
Blaivas M, Brannam L, Fernandez E. Short- axis versus long-axis approaches for teaching ultrasound- guided vascular access on a new inanimate model. Acad Emerg Med. 2003;10:1307-11.
-
(2003)
Acad Emerg Med
, vol.10
, pp. 1307-1311
-
-
Blaivas, M.1
Brannam, L.2
Fernandez, E.3
-
8
-
-
77649195911
-
Needle tip visualization during ultrasound-guided vascular access: Short-axis vs long-axis approach
-
20223394 10.1016/j.ajem.2008.11.022
-
Stone MB, Moon C, Sutijono D, Blaivas M. Needle tip visualization during ultrasound-guided vascular access: short-axis vs long-axis approach. Am J Emerg Med. 2010;28:343-7.
-
(2010)
Am J Emerg Med
, vol.28
, pp. 343-347
-
-
Stone, M.B.1
Moon, C.2
Sutijono, D.3
Blaivas, M.4
-
9
-
-
84857410971
-
Comparison of ultrasound-guided and blindly placed radial artery catheterization
-
22413453
-
Edanaga M, Mimura M, Azumaguchi T, et al. Comparison of ultrasound-guided and blindly placed radial artery catheterization. Masui. 2012;61:221-4.
-
(2012)
Masui
, vol.61
, pp. 221-224
-
-
Edanaga, M.1
Mimura, M.2
Azumaguchi, T.3
-
10
-
-
78649482846
-
Incidence of posterior vessel wall puncture during ultrasound-guided vessel cannulation in a simulated model
-
21069895 10.1111/j.1553-2712.2010.00869.x
-
Moon CH, Blehar D, Shear MA, et al. Incidence of posterior vessel wall puncture during ultrasound-guided vessel cannulation in a simulated model. Acad Emerg Med. 2010;17:1138-41.
-
(2010)
Acad Emerg Med
, vol.17
, pp. 1138-1141
-
-
Moon, C.H.1
Blehar, D.2
Shear, M.A.3
-
11
-
-
79952464046
-
Long versus short axis ultrasound guided approach for internal jugular vein cannulation: A prospective randomized controlled trial
-
Chittoodan S, Breen D, O'Donnell BD, et al. Long versus short axis ultrasound guided approach for internal jugular vein cannulation: a prospective randomized controlled trial. Med Ultrasound. 2011;13:21-5.
-
(2011)
Med Ultrasound
, vol.13
, pp. 21-25
-
-
Chittoodan, S.1
Breen, D.2
O'Donnell, B.D.3
-
12
-
-
80055078274
-
Ultrasound guided radial artery cannulation: Procedure description and literature review
-
21256787 10.1016/j.enfi.2010.11.007 1:STN:280:DC%2BC3MbmtFGlug%3D%3D
-
Carmona Monge FJ, Martínez Lareo M, Núñez Reiz A. Ultrasound guided radial artery cannulation: procedure description and literature review. Enferm Intensiva. 2011;22:144-9.
-
(2011)
Enferm Intensiva
, vol.22
, pp. 144-149
-
-
Carmona Monge, F.J.1
Martínez Lareo, M.2
Núñez Reiz, A.3
-
13
-
-
33645055711
-
Use of ultrasonography as a rescue technique for failed radial artery cannulation
-
10.1016/j.jclinane.2005.06.011
-
Sandhu NS. Use of ultrasonography as a rescue technique for failed radial artery cannulation. J Clin Anesth. 2004;18:138-41.
-
(2004)
J Clin Anesth
, vol.18
, pp. 138-141
-
-
Sandhu, N.S.1
-
14
-
-
79960398837
-
The effect of catheter to vein ratio on blood flow rates in a simulated model of peripherally inserted central venous catheter
-
21349931 10.1378/chest.10-2637
-
Nifong TP, Mc Devitt TJ. The effect of catheter to vein ratio on blood flow rates in a simulated model of peripherally inserted central venous catheter. Chest. 2011;140:48-53.
-
(2011)
Chest
, vol.140
, pp. 48-53
-
-
Nifong, T.P.1
Mc Devitt, T.J.2
|