메뉴 건너뛰기




Volumn 13, Issue 6, 2013, Pages 6946-6956

Detection of fibrinogen and coagulation factor VIII in plasma by a quartz crystal microbalance biosensor

Author keywords

Biosensor; Coagulation factor VIII; Fibrinogen; Quartz crystal microbalance

Indexed keywords

COAGULATION; OPTICAL CORRELATION; PLASMAS; QUARTZ CRYSTAL MICROBALANCES;

EID: 84878326369     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s130606946     Document Type: Article
Times cited : (26)

References (26)
  • 1
    • 48349098951 scopus 로고    scopus 로고
    • Investigation of fibrinogen adsorption on solid surface by quartz crystal microbalance with dissipation (QCM-D) and ELISA
    • Li, G.; Shi, X.; Yang, P.; Zhao, A.; Huang, N. Investigation of fibrinogen adsorption on solid surface by quartz crystal microbalance with dissipation (QCM-D) and ELISA. Solid State Ionics 2008, 179, 932-935.
    • (2008) Solid State Ionics , vol.179 , pp. 932-935
    • Li, G.1    Shi, X.2    Yang, P.3    Zhao, A.4    Huang, N.5
  • 2
    • 0024555485 scopus 로고
    • Factor VIII gene and hemophilia A
    • White, G.C.; Shoemaker, C.B. Factor VIII gene and hemophilia A. Blood 1989, 73, 1-12.
    • (1989) Blood , vol.73 , pp. 1-12
    • White, G.C.1    Shoemaker, C.B.2
  • 6
    • 79958061874 scopus 로고    scopus 로고
    • Regulation of coagulation factors during liver regeneration in mice: Mechanism of factor VIII elevation in plasma
    • Tatsumi, K.; Ohashi. K.; Taminishi, S.; Sakurai, Y.; Ogiwara, K.; Yoshioka, A.; Okano, T.; Shima, M. Regulation of coagulation factors during liver regeneration in mice: Mechanism of factor VIII elevation in plasma. Thromb. Res. 2011, 128, 54-61.
    • (2011) Thromb. Res. , vol.128 , pp. 54-61
    • Tatsumi, K.1    Ohashi, K.2    Taminishi, S.3    Sakurai, Y.4    Ogiwara, K.5    Yoshioka, A.6    Okano, T.7    Shima, M.8
  • 7
    • 0038311561 scopus 로고    scopus 로고
    • Relationship of activated partial thromboplastin time to coronary events and bleeding in patients with acute coronary syndromes who receive heparin
    • Anand, S.S.; Yusuf, S.; Pogue, J.; Ginsberg, J.S.; Hirsh, J. Relationship of activated partial thromboplastin time to coronary events and bleeding in patients with acute coronary syndromes who receive heparin. Circulation 2003, 107, 2884-2888.
    • (2003) Circulation , vol.107 , pp. 2884-2888
    • Anand, S.S.1    Yusuf, S.2    Pogue, J.3    Ginsberg, J.S.4    Hirsh, J.5
  • 8
    • 0036507772 scopus 로고    scopus 로고
    • Measuring the degree of plasma contact activation induced by artificial materials
    • Sanchez, J.; Lundquist, P.B.; Elgue, G.; Larsson, R.; Olsson, P. Measuring the degree of plasma contact activation induced by artificial materials. Thromb. Res. 2002, 105, 407-412.
    • (2002) Thromb. Res. , vol.105 , pp. 407-412
    • Sanchez, J.1    Lundquist, P.B.2    Elgue, G.3    Larsson, R.4    Olsson, P.5
  • 13
    • 0036719909 scopus 로고    scopus 로고
    • Surface plasmon resonance and free oscillation rheometry in combination: A useful approach for studies on haemostasis and interactions between whole blood and artificial surfaces
    • Hansson, K.M.; Tengvall, P.; Lundstrom, I.; Ranby, M.; Lindahl, T.L. Surface plasmon resonance and free oscillation rheometry in combination: A useful approach for studies on haemostasis and interactions between whole blood and artificial surfaces. Biosens. Bioelectron. 2002, 17, 747-759.
    • (2002) Biosens. Bioelectron. , vol.17 , pp. 747-759
    • Hansson, K.M.1    Tengvall, P.2    Lundstrom, I.3    Ranby, M.4    Lindahl, T.L.5
  • 15
    • 22944477059 scopus 로고    scopus 로고
    • Comparing a piezoelectric quartz crystal with an optical coagulometer in monitoring high-dose heparin therapy by determining whole blood activated partial thromboplastin time and activated clotting time
    • Lin, T.M.; Cheng, T.J.; Wu, T.H.; Chang, H.C. Comparing a piezoelectric quartz crystal with an optical coagulometer in monitoring high-dose heparin therapy by determining whole blood activated partial thromboplastin time and activated clotting time. Sens. Actuators B Chem. 2005, 109, 270-277.
    • (2005) Sens. Actuators B Chem. , vol.109 , pp. 270-277
    • Lin, T.M.1    Cheng, T.J.2    Wu, T.H.3    Chang, H.C.4
  • 16
    • 20444461522 scopus 로고    scopus 로고
    • Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces
    • Andersson, M.; Andersson, J.; Sellborn, A.; Berglin, M.; Nilsson, B.; Elwing, H. Quartz crystal microbalance-with dissipation monitoring (QCM-D) for real time measurements of blood coagulation density and immune complement activation on artificial surfaces. Biosens. Bioelectron. 2005, 21, 79-86.
    • (2005) Biosens. Bioelectron. , vol.21 , pp. 79-86
    • Andersson, M.1    Andersson, J.2    Sellborn, A.3    Berglin, M.4    Nilsson, B.5    Elwing, H.6
  • 17
    • 56749156408 scopus 로고    scopus 로고
    • Change of viscoelastic property and morphology of fibrin affected by antithrombin III and heparin: QCM-Z and AFM study
    • Jung, H.; Tae, G.; Kim, Y.H.; Johannsmann, D. Change of viscoelastic property and morphology of fibrin affected by antithrombin III and heparin: QCM-Z and AFM study. Colloid. Surf. B Biointerfaces 2009, 68, 111-119.
    • (2009) Colloid. Surf. B Biointerfaces , vol.68 , pp. 111-119
    • Jung, H.1    Tae, G.2    Kim, Y.H.3    Johannsmann, D.4
  • 18
    • 0037403263 scopus 로고    scopus 로고
    • Conventional detection method of fibrinogen and fibrin degradation products using latex piezoelectric immunoassay
    • Aizawa, H.; Kurosawa, S.; Tozuka, M.; Park, J.W.; Kobayashi, K.; Tanaka, H. Conventional detection method of fibrinogen and fibrin degradation products using latex piezoelectric immunoassay. Biosens. Bioelectron. 2003, 18, 765-771.
    • (2003) Biosens. Bioelectron. , vol.18 , pp. 765-771
    • Aizawa, H.1    Kurosawa, S.2    Tozuka, M.3    Park, J.W.4    Kobayashi, K.5    Tanaka, H.6
  • 19
    • 2542457843 scopus 로고    scopus 로고
    • Rapid detection of fibrinogen and fibrin degradation products using a smart QCM-sensor
    • Aizawa, H.; Kurosawa, S.; Tozuka, M.; Park, J.W.; Kobayashi, K. Rapid detection of fibrinogen and fibrin degradation products using a smart QCM-sensor. Sens. Actuators B Chem. 2004, 101, 150-154.
    • (2004) Sens. Actuators B Chem. , vol.101 , pp. 150-154
    • Aizawa, H.1    Kurosawa, S.2    Tozuka, M.3    Park, J.W.4    Kobayashi, K.5
  • 20
    • 0025737546 scopus 로고
    • A quartz crystal viscosity sensor for monitoring coagulation reaction and its application to a multichannel coagulation detector
    • Muramatsu, H.; Kimura, K.; Ataka, T.; Homma, R.; Miura, Y.; Karube, I. A quartz crystal viscosity sensor for monitoring coagulation reaction and its application to a multichannel coagulation detector. Biosens. Bioelectron. 1991, 6, 353-358.
    • (1991) Biosens. Bioelectron. , vol.6 , pp. 353-358
    • Muramatsu, H.1    Kimura, K.2    Ataka, T.3    Homma, R.4    Miura, Y.5    Karube, I.6
  • 21
    • 0032007007 scopus 로고    scopus 로고
    • A piezoelectric quartz crystal sensor for the determination of coagulation time in plasma and whole blood
    • Cheng, T.J.; Chang, H.C.; Lin, T.M. A piezoelectric quartz crystal sensor for the determination of coagulation time in plasma and whole blood. Biosens. Bioelectron. 1998, 13, 147-156.
    • (1998) Biosens. Bioelectron. , vol.13 , pp. 147-156
    • Cheng, T.J.1    Chang, H.C.2    Lin, T.M.3
  • 22
    • 0033724333 scopus 로고    scopus 로고
    • Detection of coagulation time in whole blood containing anticoagulant by piezoelectric quartz crystal sensor
    • Chang, H.C.; Cheng, T.J.; Wu, T.H.; Lin, T.M. Detection of coagulation time in whole blood containing anticoagulant by piezoelectric quartz crystal sensor. Sens. Actuators B Chem. 2000, 66, 296-298.
    • (2000) Sens. Actuators B Chem. , vol.66 , pp. 296-298
    • Chang, H.C.1    Cheng, T.J.2    Wu, T.H.3    Lin, T.M.4
  • 23
    • 0035932553 scopus 로고    scopus 로고
    • Determination of heparin levels in blood with activated partial thromboplastin time by a piezoelectric quartz crystal sensor
    • Cheng, T.J.; Lin, T.M.; Wu, T.H.; Chang, H.C. Determination of heparin levels in blood with activated partial thromboplastin time by a piezoelectric quartz crystal sensor. Anal. Chim. Acta 2001, 432, 101-111.
    • (2001) Anal. Chim. Acta , vol.432 , pp. 101-111
    • Cheng, T.J.1    Lin, T.M.2    Wu, T.H.3    Chang, H.C.4
  • 24
    • 67650085486 scopus 로고    scopus 로고
    • Rapid detection of human papilloma virus using a novel leaky surface acoustic wave peptide nucleic acid biosensor
    • Wang, Y.; Chen, M.; Zhang, L.; Ding, Y.; Luo, Y.; Xu, Q.; Shi, J.; Cao, L.; Fu, W. Rapid detection of human papilloma virus using a novel leaky surface acoustic wave peptide nucleic acid biosensor. Biosens. Bioelectron. 2009, 24, 3455-3460.
    • (2009) Biosens. Bioelectron , vol.24 , pp. 3455-3460
    • Wang, Y.1    Chen, M.2    Zhang, L.3    Ding, Y.4    Luo, Y.5    Xu, Q.6    Shi, J.7    Cao, L.8    Fu, W.9
  • 26
    • 41849106147 scopus 로고    scopus 로고
    • Usefulness of high-concentration calcium chloride solution for correction of activated partial thromboplastin time (APTT) in patients with high-hematocrit value
    • Kanahara, M.; Kai, H.; Okamura, T.; Wada, T.; Suda, K.; Imaizumi, T.; Sagawa, K. Usefulness of high-concentration calcium chloride solution for correction of activated partial thromboplastin time (APTT) in patients with high-hematocrit value. Thromb. Res. 2008, 121, 781-785.
    • (2008) Thromb. Res. , vol.121 , pp. 781-785
    • Kanahara, M.1    Kai, H.2    Okamura, T.3    Wada, T.4    Suda, K.5    Imaizumi, T.6    Sagawa, K.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.