메뉴 건너뛰기




Volumn 8668, Issue , 2013, Pages

Multi-energy performance of a research prototype CT scanner with small-pixel counting detector

Author keywords

CT; Dual energy CT; Photon counting; Spectral CT

Indexed keywords

CLINICAL APPLICATION; CT; DUAL-ENERGY CT; EXPERIMENTAL DATUM; MATERIAL SEPARATION; MATHEMATICAL FRAMEWORKS; PHOTON COUNTING; SPECTRAL CT;

EID: 84878322884     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.2006747     Document Type: Conference Paper
Times cited : (48)

References (9)
  • 2
    • 79955747289 scopus 로고    scopus 로고
    • Contrast-enhancement, image noise and dual-energy simulations for quantum-counting clinical CT
    • S. Kappler et al., Contrast-enhancement, image noise and dual-energy simulations for quantum-counting clinical CT, Proceedings of the SPIE Medical Imaging Conference, Volume 7622, pp. 76223H (2010).
    • (2010) Proceedings of the SPIE Medical Imaging Conference , vol.7622
    • Kappler, S.1
  • 3
    • 0017693719 scopus 로고
    • Selective iodine imaging using k-edge energies in computerized x-ray tomography
    • S.J. Riederer et al., Selective iodine imaging using k-edge energies in computerized x-ray tomography, Med. Phys. 4, pp. 474481 (1977).
    • (1977) Med. Phys. , vol.4 , pp. 474481
    • Riederer, S.J.1
  • 4
    • 0010361109 scopus 로고
    • Energy selective radiography: A review
    • edited by J. Kareiakes, S. Thomas and C. Orton (New York: Plenum)
    • L. Lehmann et al., Energy selective radiography: a review, Digital Radiography: Selected Topics edited by J. Kareiakes, S. Thomas and C. Orton (New York: Plenum) pp. 14588 (1986).
    • (1986) Digital Radiography: Selected Topics , pp. 14588
    • Lehmann, L.1
  • 5
    • 0032679597 scopus 로고    scopus 로고
    • Basis material decomposition using triple-energy x-ray computed tomography
    • P. Sukovic et al., Basis material decomposition using triple-energy x-ray computed tomography, Proc. 16th IEEE Instrum. Meas. Technol. Conf. vol 3, pp 16158 (1999).
    • (1999) Proc. 16th IEEE Instrum. Meas. Technol. Conf. , vol.3 , pp. 16158
    • Sukovic, P.1
  • 6
    • 23844450995 scopus 로고    scopus 로고
    • A method for stoichiometric material reconstruction with spectroscopic x-ray pixel detectors
    • M. Firsching et al., A method for stoichiometric material reconstruction with spectroscopic x-ray pixel detectors, Nuclear Science Symp. Conf. Record vol. 7, pp. 41164119 (2004).
    • (2004) Nuclear Science Symp. Conf. Record , vol.7 , pp. 41164119
    • Firsching, M.1
  • 7
    • 34547137886 scopus 로고    scopus 로고
    • K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
    • E. Roessl et al., K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors, Phys. Med. Biol. 52, pp. 4679-4696 (2007).
    • (2007) Phys. Med. Biol. , vol.52 , pp. 4679-4696
    • Roessl, E.1
  • 8
    • 84860372496 scopus 로고    scopus 로고
    • First results from a hybrid prototype CT scanner for exploring benefits of quantum-counting in clinical CT
    • S. Kappler et al., First results from a hybrid prototype CT scanner for exploring benefits of quantum-counting in clinical CT, Proceedings of the SPIE Medical Imaging Conference, Volume 8313, pp. 83130X (2012).
    • (2012) Proceedings of the SPIE Medical Imaging Conference , vol.8313
    • Kappler, S.1
  • 9
    • 84860374536 scopus 로고    scopus 로고
    • published by Siemens AG, Healthcare Sector, Computed Tomography, Forchheim/Germany
    • SOMATOM Definition Flash System Owner Manual, published by Siemens AG, Healthcare Sector, Computed Tomography, Forchheim/Germany, (2009).
    • (2009) SOMATOM Definition Flash System Owner Manual


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.