Region-of-interest reconstruction on medical c-arms with the ATRACT algorithm
-
San Diego, California, USA
-
Dennerlein F, Maier A, "Region-Of-Interest Reconstruction on medical C-arms with the ATRACT Algorithm, " in Proceedings SPIE 8313, San Diego, California, USA, 2012, p. 83131B.
-
(2012)
Proceedings SPIE
, vol.8313
-
-
Dennerlein, F.1
Maier, A.2
-
2
-
-
84878280130
-
The value of volume of interest (VOI) c-arm ct imaging in the endovascular treatment of intracranial aneurysms - A feasibility study
-
New York, NY, USA, 12-O-1509-ASNR
-
Chintalapani G, Chinnadurai P, Maier A, Shaltomi H, Morsi H, Mawad M, "The Value of Volume of Interest (VOI) C-arm CT Imaging in the Endovascular Treatment of Intracranial Aneurysms - A Feasibility Study, " in Proc. ASNR 50th Annual Meeting, New York, NY, USA, 2012, pp. 12-O-1509-ASNR.
-
(2012)
Proc. ASNR 50th Annual Meeting
-
-
Chintalapani, G.1
Chinnadurai, P.2
Maier, A.3
Shaltomi, H.4
Morsi, H.5
Mawad, M.6
-
3
-
-
33845328849
-
Dose and image quality for a cone-beam c-arm CT system
-
Fahrig R, Dixon R, Payne T, Morin RL, Ganguly A, Strobel N, "Dose and image quality for a cone-beam C-arm CT system, " Medical Physics, vol. 33, no. 12, pp. 4541-50, 2006.
-
(2006)
Medical Physics
, vol.33
, Issue.12
, pp. 4541-4550
-
-
Fahrig, R.1
Dixon, R.2
Payne, T.3
Morin, R.L.4
Ganguly, A.5
Strobel, N.6
-
4
-
-
77953527084
-
Volume-of-interest (VOI) imaging in c-arm flat-detector CT for high image quality at reduced dose
-
Kolditz D, Kyriakou Y, Kalender WA, "Volume-of-interest (VOI) imaging in C-arm flat-detector CT for high image quality at reduced dose, " Medical Physics, vol. 37, no. 6, pp. 2719-2730, 2010.
-
(2010)
Medical Physics
, vol.37
, Issue.6
, pp. 2719-2730
-
-
Kolditz, D.1
Kyriakou, Y.2
Kalender, W.A.3
-
5
-
-
42449133835
-
Tiny a priori knowledge solves the interior problem in computed tomography
-
Kudo H, Courdurier M, Noo F, Defrise M, "Tiny a priori knowledge solves the interior problem in computed tomography, " Physics in medicine and biology, vol. 53, no. 9, pp. 2207-2231, 2008.
-
(2008)
Physics in Medicine and Biology
, vol.53
, Issue.9
, pp. 2207-2231
-
-
Kudo, H.1
Courdurier, M.2
Noo, F.3
Defrise, M.4
-
6
-
-
84878295730
-
Evaluation of interpolation methods for motion compensated tomographic reconstruction for cardiac angiographic c-arm data
-
Salt Lake City, UT, USA
-
Mueller K, Zheng Y, Lauritsch G, Rohkohl C, Schwemmer C, Maier AK, Fahrig R, Hornegger J, "Evaluation of interpolation methods for motion compensated tomographic reconstruction for cardiac angiographic C-arm data, " in Proc. CT Meeting, Salt Lake City, UT, USA, 2012, pp. 5-8.
-
(2012)
Proc. CT Meeting
, pp. 5-8
-
-
Mueller, K.1
Zheng, Y.2
Lauritsch, G.3
Rohkohl, C.4
Schwemmer, C.5
Maier, A.K.6
Fahrig, R.7
Hornegger, J.8
-
7
-
-
84878301946
-
4D-ct reconstrucion using sparsity level constrained compressed sensing
-
Salt Lake City
-
Wu H, Maier A, Hofmann H, Fahrig R, Hornegger J, "4D-CT Reconstrucion Using Sparsity Level Constrained Compressed Sensing, " in 2nd CT Meeting, Salt Lake City, 2012, pp. 206-209.
-
(2012)
2nd CT Meeting
, pp. 206-209
-
-
Wu, H.1
Maier, A.2
Hofmann, H.3
Fahrig, R.4
Hornegger, J.5
-
8
-
-
67649892573
-
Compressed sensing based interior tomography
-
Yu H, Wang G, "Compressed sensing based interior tomography, " Physics in Medicine and Biology, vol. 54, no. 9, pp. 2791-2805, 2009.
-
(2009)
Physics in Medicine and Biology
, vol.54
, Issue.9
, pp. 2791-2805
-
-
Yu, H.1
Wang, G.2
-
9
-
-
0033954645
-
Efficient correction for ct image artifacts caused by objects extending outside the scan field of view
-
Ohnesorge B, Flohr T, Schwarz K, Heiken JP, Bae KT, "Efficient correction for CT image artifacts caused by objects extending outside the scan field of view., " Medical Physics, vol. 27, no. 1, pp. 39-46, 2000.
-
(2000)
Medical Physics
, vol.27
, Issue.1
, pp. 39-46
-
-
Ohnesorge, B.1
Flohr, T.2
Schwarz, K.3
Heiken, J.P.4
Bae, K.T.5
-
10
-
-
4644290361
-
A novel reconstruction algorithm to extend the CT scan field-of-view
-
Hsieh J, Chao E. Thibault J, Grekowicz B, Horst A, McOlash S, "A novel reconstruction algorithm to extend the CT scan field-of-view, " Medical Physics, vol. 31, no. 9, pp. 2385-2391, 2004.
-
(2004)
Medical Physics
, vol.31
, Issue.9
, pp. 2385-2391
-
-
Hsieh, J.1
Chao, E.T.J.2
Grekowicz, B.3
Horst, A.4
McOlash, S.5
-
11
-
-
84878323364
-
Optimization-based extrapolation for truncation correction
-
Salt Lake City, UT, USA
-
Maier A, Scholz B, Dennerlein F, "Optimization-based Extrapolation for Truncation Correction, " in 2nd CT Meeting, Salt Lake City, UT, USA, 2012, pp. 390-394.
-
(2012)
2nd CT Meeting
, pp. 390-394
-
-
Maier, A.1
Scholz, B.2
Dennerlein, F.3
-
12
-
-
84878322478
-
Efficient 2d filtering for cone-beam VOI reconstruction
-
Anaheim, CA, USA, p. to appear
-
Xia Y, Maier A, Dennerlein F, Hofmann HG, Hornegger J, "Efficient 2D Filtering for Cone-Beam VOI Reconstruction, " in 2012 IEEE MIC, Anaheim, CA, USA, 2012, p. to appear.
-
(2012)
2012 IEEE MIC
-
-
Xia, Y.1
Maier, A.2
Dennerlein, F.3
Hofmann, H.G.4
Hornegger, J.5
-
13
-
-
80855134338
-
Three-dimensional anisotropic adaptive filtering of projection data for noise reduction in cone beam CT
-
Maier A, Wigström L, Hofmann HG, Hornegger J, Zhu L, Strobel N, Fahrig R, "Three-dimensional Anisotropic Adaptive Filtering of Projection Data for Noise Reduction in Cone Beam CT, " Medical Physics, vol. 38, no. 11, pp. 5896-5909, 2011.
-
(2011)
Medical Physics
, vol.38
, Issue.11
, pp. 5896-5909
-
-
Maier, A.1
Wigström, L.2
Hofmann, H.G.3
Hornegger, J.4
Zhu, L.5
Strobel, N.6
Fahrig, R.7
-
14
-
-
0031546042
-
Use of a c-arm system to generate true three-dimensional computed rotational angiograms: Preliminary in vitro and in vivo results
-
Fahrig R, Fox AJ, Lownie S, Holdsworth DW, "Use of a C-arm system to generate true three-dimensional computed rotational angiograms: preliminary in vitro and in vivo results, " American Journal of Neuroradiology, vol. 18, no. 8, pp. 1507-14, 1997.
-
(1997)
American Journal of Neuroradiology
, vol.18
, Issue.8
, pp. 1507-1514
-
-
Fahrig, R.1
Fox, A.J.2
Lownie, S.3
Holdsworth, D.W.4
-
15
-
-
79955782010
-
Analysis of vertical and horizontal circular c-arm trajectories
-
Lake Buena Vista, Florida, USA
-
Maier A, Choi JH, Keil A, Niebler C, Sarmiento M, Fieselmann A, Gold G, Delp S, Fahrig R, "Analysis of Vertical and Horizontal Circular C-Arm Trajectories, " in Proceedings SPIE 7961, Lake Buena Vista, Florida, USA, 2011, p. 796123.
-
(2011)
Proceedings SPIE
, vol.7961
, pp. 796123
-
-
Maier, A.1
Choi, J.H.2
Keil, A.3
Niebler, C.4
Sarmiento, M.5
Fieselmann, A.6
Gold, G.7
Delp, S.8
Fahrig, R.9
-
16
-
-
43049174575
-
Speeded-up robust features (SURF)
-
Bay H, Ess A, Tuytelaars T, Van Gool L, "Speeded-up robust Features (SURF), " Computer Vision and Image Understanding, vol. 110, pp. 346-359, 2008.
-
(2008)
Computer Vision and Image Understanding
, vol.110
, pp. 346-359
-
-
Bay, H.1
Ess, A.2
Tuytelaars, T.3
Van Gool, L.4
-
17
-
-
0000325341
-
On lines and planes of closest fit to systems of points in space
-
Pearson K, "On lines and planes of closest fit to systems of points in space, " Philosophical Magazine, vol. 2, no. 6, pp. 559-572, 1901.
-
(1901)
Philosophical Magazine
, vol.2
, Issue.6
, pp. 559-572
-
-
Pearson, K.1
-
18
-
-
0019574599
-
Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography
-
Fischler MA, Bolles RC, "Random sample consensus: A paradigm for model fitting with applications to image analysis and automated cartography, " Communications of the ACM, vol. 24, no. 6, pp. 381-395, 1981.
-
(1981)
Communications of the ACM
, vol.24
, Issue.6
, pp. 381-395
-
-
Fischler, M.A.1
Bolles, R.C.2
-
19
-
-
84866339020
-
Diaphragm tracking for respiratory motion compensated cardiac c-arm CT
-
Salt Lake City, UT, USA
-
Bögel M, Maier A, Hofmann HG, Hornegger J, Fahrig R, "Diaphragm Tracking for Respiratory Motion Compensated Cardiac C-Arm CT, " in Proc. CT Meeting, Salt Lake City, UT, USA, 2012, pp. 13-16.
-
(2012)
Proc. CT Meeting
, pp. 13-16
-
-
Bögel, M.1
Maier, A.2
Hofmann, H.G.3
Hornegger, J.4
Fahrig, R.5
-
20
-
-
84884480952
-
Diaphragm tracking in cardiac c-arm projection data
-
Berlin, Germany
-
Bögel M, Maier A, Hofmann HG, Hornegger J, Fahrig R, "Diaphragm Tracking in Cardiac C-Arm Projection Data, " in Proc. BVM, Berlin, Germany, 2012, pp. 33-38.
-
(2012)
Proc. BVM
, pp. 33-38
-
-
Bögel, M.1
Maier, A.2
Hofmann, H.G.3
Hornegger, J.4
Fahrig, R.5
-
21
-
-
84866340675
-
Fast simulation of x-ray projections of spline-based surfaces using an append buffer
-
Maier A, Hofmann HG, Schwemmer C, Hornegger J, Keil A, Fahrig R, "Fast Simulation of X-ray Projections of Spline-based Surfaces using an Append Buffer, " Physics in Medicine and Biology, vol. 57, no. 19, pp. 6193-6210, 2012.
-
(2012)
Physics in Medicine and Biology
, vol.57
, Issue.19
, pp. 6193-6210
-
-
Maier, A.1
Hofmann, H.G.2
Schwemmer, C.3
Hornegger, J.4
Keil, A.5
Fahrig, R.6
|