메뉴 건너뛰기




Volumn 17, Issue 5, 2013, Pages 1389-1395

Computer-aided evaluation of preparations for CAD/CAM-fabricated all-ceramic crowns

Author keywords

All ceramic crowns; CAD CAM; Digital evaluation; Preparation geometry; Zirconia

Indexed keywords


EID: 84878276506     PISSN: 14326981     EISSN: 14363771     Source Type: Journal    
DOI: 10.1007/s00784-012-0812-3     Document Type: Article
Times cited : (36)

References (39)
  • 1
    • 0036561773 scopus 로고    scopus 로고
    • Tooth structure removal associated with various preparation designs for anterior teeth
    • Edelhoff D, Sorensen JA (2002) Tooth structure removal associated with various preparation designs for anterior teeth. J Prosthet Dent 87: 503-509.
    • (2002) J Prosthet Dent , vol.87 , pp. 503-509
    • Edelhoff, D.1    Sorensen, J.A.2
  • 2
    • 0035318605 scopus 로고    scopus 로고
    • Tooth preparations for complete crowns: an art of form based on scientific principles
    • Goodacre CJ, Campagni WV, Aquilion SA (2001) Tooth preparations for complete crowns: an art of form based on scientific principles. J Prosthet Dent 85: 363-376.
    • (2001) J Prosthet Dent , vol.85 , pp. 363-376
    • Goodacre, C.J.1    Campagni, W.V.2    Aquilion, S.A.3
  • 4
    • 0016841625 scopus 로고
    • The taper of inlay and crown preparations. A contribution to dental terminology
    • Rosenstiel E (1975) The taper of inlay and crown preparations. A contribution to dental terminology. Br Dent J 139: 436-438.
    • (1975) Br Dent J , vol.139 , pp. 436-438
    • Rosenstiel, E.1
  • 5
    • 67651011653 scopus 로고    scopus 로고
    • Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings
    • Beuer F, Aggstaller H, Richter J, Edelhoff D, Gernet W (2009) Influence of preparation angle on marginal and internal fit of CAD/CAM-fabricated zirconia crown copings. Quintessence Int 40: 243-250.
    • (2009) Quintessence Int , vol.40 , pp. 243-250
    • Beuer, F.1    Aggstaller, H.2    Richter, J.3    Edelhoff, D.4    Gernet, W.5
  • 6
    • 57449093791 scopus 로고    scopus 로고
    • Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system
    • Beuer F, Edelhoff D, Gernet W, Naumann M (2008) Effect of preparation angles on the precision of zirconia crown copings fabricated by CAD/CAM system. Dent Mater J 27: 814-820.
    • (2008) Dent Mater J , vol.27 , pp. 814-820
    • Beuer, F.1    Edelhoff, D.2    Gernet, W.3    Naumann, M.4
  • 7
    • 0030095397 scopus 로고    scopus 로고
    • The relationship between abutment taper and resistance of cemented crowns to dynamic loading
    • Wiskott HWA, Nicholls JI, Belser U (1996) The relationship between abutment taper and resistance of cemented crowns to dynamic loading. Int J Prosthodont 9: 117-139.
    • (1996) Int J Prosthodont , vol.9 , pp. 117-139
    • Wiskott, H.W.A.1    Nicholls, J.I.2    Belser, U.3
  • 8
    • 0028457336 scopus 로고
    • The relationship between preparation convergence and retention of extracoronal retainers
    • Wilson AH Jr, Chan DC (1994) The relationship between preparation convergence and retention of extracoronal retainers. J Prosthodont 3: 74-78.
    • (1994) J Prosthodont , vol.3 , pp. 74-78
    • Wilson Jr., A.H.1    Chan, D.C.2
  • 9
    • 0016272301 scopus 로고
    • Fundamentals of extracoronal tooth preparation. Part I, retention and resistance form
    • Giiboe DB, Teteruck WR (1974) Fundamentals of extracoronal tooth preparation. Part I, retention and resistance form. Prosthet Dent 32: 651-656.
    • (1974) Prosthet Dent , vol.32 , pp. 651-656
    • Giiboe, D.B.1    Teteruck, W.R.2
  • 10
    • 0039999335 scopus 로고
    • The relationship between retention and convergence angle in cemented veneer crowns
    • Jorgensen KD (1955) The relationship between retention and convergence angle in cemented veneer crowns. Acta Odontol Scan 13: 35-40.
    • (1955) Acta Odontol Scan , vol.13 , pp. 35-40
    • Jorgensen, K.D.1
  • 11
    • 0141436371 scopus 로고
    • Factors influencing the retention of cemented gold castings
    • Kaufman EG, Coelho DH, Colin L (1961) Factors influencing the retention of cemented gold castings. J Prosth Dent 11: 487-502.
    • (1961) J Prosth Dent , vol.11 , pp. 487-502
    • Kaufman, E.G.1    Coelho, D.H.2    Colin, L.3
  • 12
    • 65549131979 scopus 로고    scopus 로고
    • Effect of proximal wall height on all-ceramic crown core stress distribution: a finite element analysis study
    • Coelho PG, Silva NR, Thompson VP, Rekow D, Zhang G (2009) Effect of proximal wall height on all-ceramic crown core stress distribution: a finite element analysis study. Int J Prosthodont 22: 78-86.
    • (2009) Int J Prosthodont , vol.22 , pp. 78-86
    • Coelho, P.G.1    Silva, N.R.2    Thompson, V.P.3    Rekow, D.4    Zhang, G.5
  • 13
    • 13444311681 scopus 로고    scopus 로고
    • The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns
    • De Jager N, Pallev P, Feilzer AJ (2005) The influence of design parameters on the FEA-determined stress distribution in CAD-CAM produced all-ceramic dental crowns. Dent Mater 21: 242-251.
    • (2005) Dent Mater , vol.21 , pp. 242-251
    • De Jager, N.1    Pallev, P.2    Feilzer, A.J.3
  • 14
    • 34250649888 scopus 로고    scopus 로고
    • To what extent does the logevity of fixed dental prostheses depend on the function of the cement?
    • Edelhoff D, Özcan M (2007) To what extent does the logevity of fixed dental prostheses depend on the function of the cement? Clin Oral Impl Res 18: 193-204.
    • (2007) Clin Oral Impl Res , vol.18 , pp. 193-204
    • Edelhoff, D.1    Özcan, M.2
  • 16
    • 33744916011 scopus 로고    scopus 로고
    • The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading
    • Cameron SM, Morris WJ, Keesee SM, Barsky TB, Parker MH (2006) The effect of preparation taper on the retention of cemented cast crowns under lateral fatigue loading. J Prosth Dent 95: 456-461.
    • (2006) J Prosth Dent , vol.95 , pp. 456-461
    • Cameron, S.M.1    Morris, W.J.2    Keesee, S.M.3    Barsky, T.B.4    Parker, M.H.5
  • 17
    • 1642368869 scopus 로고    scopus 로고
    • Convergence angle, occlusal reduction, and finish line depth of full-crown preparations made by dental students
    • Al-Omari WM, Al-Wahadni AM (2004) Convergence angle, occlusal reduction, and finish line depth of full-crown preparations made by dental students. Quintessence Int 35: 287-292.
    • (2004) Quintessence Int , vol.35 , pp. 287-292
    • Al-Omari, W.M.1    Al-Wahadni, A.M.2
  • 18
    • 77957306070 scopus 로고    scopus 로고
    • Taper of full-veneer crown preparations by dental students at the University of the West Indies
    • Rafeek RN, Smith WAJ, Seymour KG, Zou LF, Samarawickrama DYD (2010) Taper of full-veneer crown preparations by dental students at the University of the West Indies. J Prosthodont 19: 580-585.
    • (2010) J Prosthodont , vol.19 , pp. 580-585
    • Rafeek, R.N.1    Smith, W.A.J.2    Seymour, K.G.3    Zou, L.F.4    Samarawickrama, D.Y.D.5
  • 19
    • 0024058379 scopus 로고
    • The taper of clinical preparations for fixed prosthodontics
    • NordlanderJ WD, Stoffer W et al (1988) The taper of clinical preparations for fixed prosthodontics. J Prosthet Dent 60: 148-151.
    • (1988) J Prosthet Dent , vol.60 , pp. 148-151
    • Nordlander, J.W.D.1    Stoffer, W.2
  • 20
    • 84864283529 scopus 로고    scopus 로고
    • Evaluation of impression accuracy for a four-implant mandibular model-a digital approach
    • PMID: 22009182
    • Stimmelmayr M, Erdelt K, Güth JF, Happe A, Beuer F (2012) Evaluation of impression accuracy for a four-implant mandibular model-a digital approach. Clin Oral Investig 16: 1137-1142, PMID: 22009182.
    • (2012) Clin Oral Investig , vol.16 , pp. 1137-1142
    • Stimmelmayr, M.1    Erdelt, K.2    Güth, J.F.3    Happe, A.4    Beuer, F.5
  • 21
    • 84861784308 scopus 로고    scopus 로고
    • Digital evaluation of the reproducibility of implant scanbody fit-an in vitro study
    • Stimmelmayr M, Güth JF, Erdelt K, Edelhoff D, Beuer F (2012) Digital evaluation of the reproducibility of implant scanbody fit-an in vitro study. Clin Oral Investig 16(3): 851-856.
    • (2012) Clin Oral Investig , vol.16 , Issue.3 , pp. 851-856
    • Stimmelmayr, M.1    Güth, J.F.2    Erdelt, K.3    Edelhoff, D.4    Beuer, F.5
  • 23
    • 0031129782 scopus 로고    scopus 로고
    • The effect of tooth preparation height and diameter on the resistance of complete crowns to fatigue loading
    • Wiskott HW, Nicholls JI, Belser UC (1997) The effect of tooth preparation height and diameter on the resistance of complete crowns to fatigue loading. Int J Prosthodont 10: 207-215.
    • (1997) Int J Prosthodont , vol.10 , pp. 207-215
    • Wiskott, H.W.1    Nicholls, J.I.2    Belser, U.C.3
  • 24
    • 0017507513 scopus 로고
    • Preparation areas resisting displacement of artificial crowns
    • Hegdahl T, Silness J (1977) Preparation areas resisting displacement of artificial crowns. J Oral Rehabil 4: 201-207.
    • (1977) J Oral Rehabil , vol.4 , pp. 201-207
    • Hegdahl, T.1    Silness, J.2
  • 25
    • 0032149165 scopus 로고    scopus 로고
    • A clinical study on abutment taper and height of full cast crown preparations
    • Sato T, Al Mutawa N, Okada D, Hasegawa S (1998) A clinical study on abutment taper and height of full cast crown preparations. J Med Dent Sci 45: 205-210.
    • (1998) J Med Dent Sci , vol.45 , pp. 205-210
    • Sato, T.1    Al Mutawa, N.2    Okada, D.3    Hasegawa, S.4
  • 26
    • 0030279686 scopus 로고    scopus 로고
    • Retention of metal ceramic crowns cemented with resin cements: effects of preparation taper and height
    • El-Mowafy OM, Fenton AH, Forrester N, Milenkovic M (1996) Retention of metal ceramic crowns cemented with resin cements: effects of preparation taper and height. J Prosthet Dent 76: 524-529.
    • (1996) J Prosthet Dent , vol.76 , pp. 524-529
    • El-Mowafy, O.M.1    Fenton, A.H.2    Forrester, N.3    Milenkovic, M.4
  • 27
    • 0141464000 scopus 로고    scopus 로고
    • The retention of complete crowns prepared with three different tapers and luted with four different cements
    • Zidan O, Ferguson GC (2003) The retention of complete crowns prepared with three different tapers and luted with four different cements. J Prosthet Dent 89: 565-571.
    • (2003) J Prosthet Dent , vol.89 , pp. 565-571
    • Zidan, O.1    Ferguson, G.C.2
  • 28
    • 0031131961 scopus 로고    scopus 로고
    • Effect of convergence angle on retention of resin bonded retainers cemented with resinous cements
    • Sarafianou A, Kafandaris NM (1997) Effect of convergence angle on retention of resin bonded retainers cemented with resinous cements. J Prosthet Dent 77: 475-481.
    • (1997) J Prosthet Dent , vol.77 , pp. 475-481
    • Sarafianou, A.1    Kafandaris, N.M.2
  • 29
    • 58249117718 scopus 로고    scopus 로고
    • All-ceramic single-tooth restorations: choosing the material to match the preparation-preparing the tooth to match the material
    • Baltzer A (2008) All-ceramic single-tooth restorations: choosing the material to match the preparation-preparing the tooth to match the material. Int J Comput Dent 11: 241-256.
    • (2008) Int J Comput Dent , vol.11 , pp. 241-256
    • Baltzer, A.1
  • 30
    • 29144507753 scopus 로고    scopus 로고
    • Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns
    • Bindl A, Luthy H, Moermann WH (2006) Strength and fracture pattern of monolithic CAD/CAM-generated posterior crowns. Dent Mater 22: 29-36.
    • (2006) Dent Mater , vol.22 , pp. 29-36
    • Bindl, A.1    Luthy, H.2    Moermann, W.H.3
  • 31
    • 0032112338 scopus 로고    scopus 로고
    • Effects of preparation and luting system on all-ceramic computer-generated crowns
    • Moermann WH, Bindl A, Luthy H, Rathke A (1998) Effects of preparation and luting system on all-ceramic computer-generated crowns. Int J Prosthodont 11: 333-339.
    • (1998) Int J Prosthodont , vol.11 , pp. 333-339
    • Moermann, W.H.1    Bindl, A.2    Luthy, H.3    Rathke, A.4
  • 32
    • 24044545905 scopus 로고    scopus 로고
    • Assessment of convergence angles of tooth preparations for complete crowns among dental students
    • Ayad MF, Maghrabi AA, Rosenstiel SF (2005) Assessment of convergence angles of tooth preparations for complete crowns among dental students. J Dent 33: 633-638.
    • (2005) J Dent , vol.33 , pp. 633-638
    • Ayad, M.F.1    Maghrabi, A.A.2    Rosenstiel, S.F.3
  • 33
    • 13144294051 scopus 로고    scopus 로고
    • Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns
    • Chan DC, Wilson AH Jr, Barbe P, Cronin RJ Jr et al (2005) Effect of preparation convergence on retention and seating discrepancy of complete veneer crowns. J Oral Rehabil 32: 58-64.
    • (2005) J Oral Rehabil , vol.32 , pp. 58-64
    • Chan, D.C.1    Wilson Jr., A.H.2    Barbe, P.3    Cronin Jr., R.J.4
  • 34
    • 47349106882 scopus 로고    scopus 로고
    • Influence of convergence angle and cement space on adaptation of zirconium dioxide ceramic copings
    • Iwai T, Komine F, Kobayashi K, Saito A et al (2008) Influence of convergence angle and cement space on adaptation of zirconium dioxide ceramic copings. Acta Odontol Scand 66: 214-218.
    • (2008) Acta Odontol Scand , vol.66 , pp. 214-218
    • Iwai, T.1    Komine, F.2    Kobayashi, K.3    Saito, A.4
  • 36
    • 0023970406 scopus 로고
    • Quantitative determination of taper adequate to provide resistance form: concept of limiting taper
    • Parker MH, Gunderson RB, Gardner FM, Calverley MJ (1988) Quantitative determination of taper adequate to provide resistance form: concept of limiting taper. J Prosthet Dent 59: 281-288.
    • (1988) J Prosthet Dent , vol.59 , pp. 281-288
    • Parker, M.H.1    Gunderson, R.B.2    Gardner, F.M.3    Calverley, M.J.4
  • 37
    • 0019014347 scopus 로고
    • A theoretical and clinical investigation into the taper achieved on crown and inlay preparations
    • Mack PJ (1980) A theoretical and clinical investigation into the taper achieved on crown and inlay preparations. J Oral Rehabil 7: 255-265.
    • (1980) J Oral Rehabil , vol.7 , pp. 255-265
    • Mack, P.J.1
  • 38
    • 0018022973 scopus 로고
    • The convergence angle in teeth prepared for artificial crowns
    • Ohm E, Silness J (1978) The convergence angle in teeth prepared for artificial crowns. J Oral Rehabil 5: 371-375.
    • (1978) J Oral Rehabil , vol.5 , pp. 371-375
    • Ohm, E.1    Silness, J.2
  • 39
    • 0035463838 scopus 로고    scopus 로고
    • Assessment of clinical preparations for single gold and ceramometal crowns
    • Poon BK, Smales RJ (2001) Assessment of clinical preparations for single gold and ceramometal crowns. Quintessence Int 32: 603-610.
    • (2001) Quintessence Int , vol.32 , pp. 603-610
    • Poon, B.K.1    Smales, R.J.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.