-
1
-
-
38649084899
-
-
2nd ed., A. D. Michelson, Ed., Academic Press, San Diego
-
A. D. Michelson, Platelets, 2nd ed., A. D. Michelson, Ed., Academic Press, San Diego (2006).
-
(2006)
Platelets
-
-
Michelson, A.D.1
-
2
-
-
3142524878
-
The platelet shape change
-
P. Gresele, C. P. Page, V. Fuster, and J. Vermylen, Eds. Cambridge University Press, Cambridge
-
A. R. L. Gear and R. K. Polanowska-Grabowska, "The platelet shape change," in Platelets in Thrombotic and Non-Thrombotic Disorders, P. Gresele, C. P. Page, V. Fuster, and J. Vermylen, Eds., pp. 319-337, Cambridge University Press, Cambridge (2002).
-
(2002)
Platelets in Thrombotic and Non-Thrombotic Disorders
, pp. 319-337
-
-
Gear, A.R.L.1
Polanowska-Grabowska, R.K.2
-
3
-
-
0013771729
-
The blood platelet: Electron microscopic studies
-
J. F. David-Ferreira, "The blood platelet: electron microscopic studies," Int. Rev. Cytol. 17, 99-148 (1964).
-
(1964)
Int. Rev. Cytol.
, vol.17
, pp. 99-148
-
-
David-Ferreira, J.F.1
-
4
-
-
0020008173
-
Human platelet size, shape, and related functions in health and disease
-
M. M. Frojmovic and J. G. Milton, "Human platelet size, shape, and related functions in health and disease," Physiol. Rev. 62(1), 185-261 (1982).
-
(1982)
Physiol. Rev.
, vol.62
, Issue.1
, pp. 185-261
-
-
Frojmovic, M.M.1
Milton, J.G.2
-
5
-
-
0017090878
-
Geometry of normal mammalian platelets by quantitative microscopic studies
-
M. M. Frojmovic and R. Panjwani, "Geometry of normal mammalian platelets by quantitative microscopic studies," Biophys. J. 16(9), 1071-1089 (1976).
-
(1976)
Biophys. J.
, vol.16
, Issue.9
, pp. 1071-1089
-
-
Frojmovic, M.M.1
Panjwani, R.2
-
6
-
-
84879610825
-
Platelet heterogeneity: Physiology and pathological consequences
-
P. Gresele C. P. Page, V. Fuster, and J. Vermylen, Eds. Cambridge University Press, Cambridge
-
A. Mathur and J. F. Martin, "Platelet heterogeneity: physiology and pathological consequences," in Platelets in Thrombotic and Non- Thrombotic Disorders, P. Gresele, C. P. Page, V. Fuster, and J. Vermylen, Eds., pp. 70-79, Cambridge University Press, Cambridge (2002).
-
(2002)
Platelets in Thrombotic and Non- Thrombotic Disorders
, pp. 70-79
-
-
Mathur, A.1
Martin, J.F.2
-
7
-
-
77957155336
-
Rapid whole-blood platelet counting using an electronic particle counter
-
R. D. Eastham, "Rapid whole-blood platelet counting using an electronic particle counter," J. Clin. Pathol. 16(2), 168-169 (1963).
-
(1963)
J. Clin. Pathol.
, vol.16
, Issue.2
, pp. 168-169
-
-
Eastham, R.D.1
-
8
-
-
0016710236
-
Platelet size in man
-
J. Paulus, "Platelet size in man," Blood 46(3), 321-336 (1975).
-
(1975)
Blood
, vol.46
, Issue.3
, pp. 321-336
-
-
Paulus, J.1
-
9
-
-
0014600745
-
Electrical sizing of particles in suspensions
-
N. B. Grover et al., "Electrical sizing of particles in suspensions," Biophys. J. 9(11), 1398-1414 (1969).
-
(1969)
Biophys. J.
, vol.9
, Issue.11
, pp. 1398-1414
-
-
Grover, N.B.1
-
10
-
-
0022989175
-
Mean platelet volume in the normal state and in various clinical disorders
-
K. Y. Kim, K. E. Kim, and K. H. Kim, "Mean platelet volume in the normal state and in various clinical disorders," Yonsei Med. J. 27(3), 219-226 (1986).
-
(1986)
Yonsei Med. J.
, vol.27
, Issue.3
, pp. 219-226
-
-
Kim, K.Y.1
Kim, K.E.2
Kim, K.H.3
-
11
-
-
0023185062
-
Detection of activated platelets in whole blood using activation-dependent monoclonal antibodies and flow cytometry
-
S. J. Shattil, M. Cunningham, and J. A. Hoxie, "Detection of activated platelets in whole blood using activation-dependent monoclonal antibodies and flow cytometry," Blood 70(1), 307-315 (1987). (Pubitemid 17111279)
-
(1987)
Blood
, vol.70
, Issue.1
, pp. 307-315
-
-
Shattil, S.J.1
Cunningham, M.2
Hoxie, J.A.3
-
12
-
-
0027175541
-
Annexin V as a probe of aminophospholipid exposure and platelet membrane vesiculation: A flow cytometry study showing a role for free sulfhydryl groups
-
J. Dachary-Prigent et al., "Annexin V as a probe of aminophospholipid exposure and platelet membrane vesiculation: a flow cytometry study showing a role for free sulfhydryl groups," Blood 81(10), 2554-2565 (1993). (Pubitemid 23147557)
-
(1993)
Blood
, vol.81
, Issue.10
, pp. 2554-2565
-
-
Dachary-Prigent, J.1
Freyssinet, J.-M.2
Pasquet, J.-M.3
Carron, J.-C.4
Nurden, A.T.5
-
13
-
-
67651087058
-
A rapid flow cytometric technique for the detection of platelet-monocyte complexes, activated platelets and platelet-derived microparticles
-
L. Pearson et al., "A rapid flow cytometric technique for the detection of platelet-monocyte complexes, activated platelets and platelet-derived microparticles," Int. J. Lab. Hematol. 31(4), 430-439 (2009).
-
(2009)
Int. J. Lab. Hematol.
, vol.31
, Issue.4
, pp. 430-439
-
-
Pearson, L.1
-
14
-
-
0032144775
-
Flow cytometric assays to detect platelet activation and aggregation in device-implanted calves
-
DOI 10.1002/(SICI)1097-4636(199808)41:2<312::AID-JBM17>3.0.CO;2-M
-
L. C. Baker et al., "Flow cytometric assays to detect platelet activation and aggregation in device-implanted calves," J. Biomed. Mater. Res. 41(2), 312-321 (1998). (Pubitemid 28272490)
-
(1998)
Journal of Biomedical Materials Research
, vol.41
, Issue.2
, pp. 312-321
-
-
Baker, L.C.1
Davis, W.C.2
Autieri, J.3
Watach, M.J.4
Yamazaki, K.5
Litwak, P.6
Wagner, W.R.7
-
15
-
-
34648860578
-
Past and future approaches to assess the quality of platelets for transfusion
-
DOI 10.1016/j.tmrv.2007.05.005, PII S0887796307000442
-
E. Maurer-Spurej and K. Chipperfield, "Past and future approaches to assess the quality of platelets for transfusion," Transfus. Med. Rev. 21(4), 295-306 (2007). (Pubitemid 47454557)
-
(2007)
Transfusion Medicine Reviews
, vol.21
, Issue.4
, pp. 295-306
-
-
Maurer-Spurej, E.1
Chipperfield, K.2
-
16
-
-
0018641378
-
Transformation and motility of human platelets. Details of the shape change and release reaction observed by optical and electron microscopy
-
DOI 10.1083/jcb.83.1.126
-
R. D. Allen et al., "Transformation and motility of human platelets: details of the shape change and release reaction observed by optical and electron microscopy," J. Cell Biol. 83(1), 126-142 (1979). (Pubitemid 10197039)
-
(1979)
Journal of Cell Biology
, vol.83
, Issue.1
, pp. 126-142
-
-
Allen, R.D.1
Zacharski, L.R.2
Widirstky, S.T.3
-
17
-
-
0020584164
-
Turbidometric evaluations of platelet activation: Relative contributions of measured shape change, volume, and early aggregation
-
DOI 10.1016/0160-5402(83)90002-5
-
J. G. Milton and M. M. Frojmovic, "Turbidometric evaluations of platelet activation: relative contributions of measured shape change, volume, and early aggregation," J. Pharmacol. Methods 9(2), 101-115 (1983). (Pubitemid 13094748)
-
(1983)
Journal of Pharmacological Methods
, vol.9
, Issue.2
, pp. 101-115
-
-
Milton, J.G.1
Frojmovic, M.M.2
-
18
-
-
0017902733
-
Quantification of the morphological reaction of platelets to aggregating agents and of its reversal by aggregation inhibitors
-
G. V. Born et al., "Quantification of the morphological reaction of platelets to aggregating agents and of its reversal by aggregation inhibitors," J. Physiol. (Lond.) 280, 193-212 (1978). (Pubitemid 8387971)
-
(1978)
Journal of Physiology
, vol.280
, pp. 193-212
-
-
Born, G.V.R.1
Dearnley, R.2
Foulks, J.G.3
Sharp, D.E.4
-
19
-
-
0000802530
-
Scanning flow cytometry for individual particle analysis
-
V. P. Maltsev, "Scanning flow cytometry for individual particle analysis," Rev. Sci. Instrum. 71(1), 243-255 (2000).
-
(2000)
Rev. Sci. Instrum.
, vol.71
, Issue.1
, pp. 243-255
-
-
Maltsev, V.P.1
-
21
-
-
77950346385
-
Is there a difference between T- and B-lymphocyte morphology?
-
D. I. Strokotov et al., "Is there a difference between T- and B-lymphocyte morphology?," J. Biomed. Opt. 14(6), 064036 (2009).
-
(2009)
J. Biomed. Opt.
, vol.14
, Issue.6
, pp. 064036
-
-
Strokotov, D.I.1
-
22
-
-
84866792422
-
Light-scattering flow cytometry for identification and characterization of blood microparticles
-
A. I. Konokhova et al., "Light-scattering flow cytometry for identification and characterization of blood microparticles," J. Biomed. Opt. 17(5), 057006 (2012).
-
(2012)
J. Biomed. Opt.
, vol.17
, Issue.5
, pp. 057006
-
-
Konokhova, A.I.1
-
23
-
-
33646762515
-
Determination of volume, shape and refractive index of individual blood platelets
-
I. V. Kolesnikova et al., "Determination of volume, shape and refractive index of individual blood platelets," J. Quant. Spectrosc. Radiat. Transfer 102(1), 37-45 (2006).
-
(2006)
J. Quant. Spectrosc. Radiat. Transfer
, vol.102
, Issue.1
, pp. 37-45
-
-
Kolesnikova, I.V.1
-
24
-
-
0000113350
-
Reversible alterations in platelet morphology produced by anticoagulants and by cold
-
M. B. Zucker and J. Borrelli, "Reversible alterations in platelet morphology produced by anticoagulants and by cold," Blood 9(6), 602-608 (1954).
-
(1954)
Blood
, vol.9
, Issue.6
, pp. 602-608
-
-
Zucker, M.B.1
Borrelli, J.2
-
25
-
-
79959561462
-
Polarized light-scattering profile-advanced characterization of nonspherical particles with scanning flow cytometry
-
D. I. Strokotov et al., "Polarized light-scattering profile-advanced characterization of nonspherical particles with scanning flow cytometry," Cytometry A 79(7), 570-579 (2011).
-
(2011)
Cytometry A
, vol.79
, Issue.7
, pp. 570-579
-
-
Strokotov, D.I.1
-
27
-
-
34247524094
-
The discrete dipole approximation: An overview and recent developments
-
DOI 10.1016/j.jqsrt.2007.01.034, PII S0022407307000556
-
M. A. Yurkin and A. G. Hoekstra, "The discrete dipole approximation: an overview and recent developments," J. Quant. Spectrosc. Radiat. Transfer 106(1-3), 558-589 (2007). (Pubitemid 46656928)
-
(2007)
Journal of Quantitative Spectroscopy and Radiative Transfer
, vol.106
, Issue.1-3
, pp. 558-589
-
-
Yurkin, M.A.1
Hoekstra, A.G.2
-
28
-
-
79960900591
-
The discrete-dipole-approximation code ADDA: Capabilities and known limitations
-
M. A. Yurkin and A. G. Hoekstra, "The discrete-dipole-approximation code ADDA: capabilities and known limitations," J. Quant. Spectrosc. Radiat. Transfer 112(13), 2234-2247 (2011).
-
(2011)
J. Quant. Spectrosc. Radiat. Transfer
, vol.112
, Issue.13
, pp. 2234-2247
-
-
Yurkin, M.A.1
Hoekstra, A.G.2
-
29
-
-
33751245873
-
Convergence of the discrete dipole approximation. I. Theoretical analysis
-
DOI 10.1364/JOSAA.23.002578
-
M. A. Yurkin, V. P. Maltsev, and A. G. Hoekstra, "Convergence of the discrete dipole approximation. I. Theoretical analysis," J. Opt. Soc. Am. A 23(10), 2578-2591 (2006). (Pubitemid 44781658)
-
(2006)
Journal of the Optical Society of America A: Optics and Image Science, and Vision
, vol.23
, Issue.10
, pp. 2578-2591
-
-
Yurkin, M.A.1
Maltsev, V.P.2
Hoekstra, A.G.3
-
30
-
-
0030145688
-
T-matrix computations of light scattering by nonspherical particles: A review
-
DOI 10.1016/0022-4073(96)00002-7
-
M. I. Mishchenko, L. D. Travis, and D. W. Mackowski, "T-matrix computations of light scattering by nonspherical particles: a review," J. Quant. Spectrosc. Radiat. Transfer 55(5), 535-575 (1996). (Pubitemid 126398634)
-
(1996)
Journal of Quantitative Spectroscopy and Radiative Transfer
, vol.55
, Issue.5
, pp. 535-575
-
-
Mishchenko, M.I.1
Travis, L.D.2
Mackowski, D.W.3
-
32
-
-
79958720438
-
Improving the numerical stability of T-matrix light scattering calculations for extreme particle shapes using the nullfield method with discrete sources
-
J. Hellmers, V. Schmidt, and T. Wriedt, "Improving the numerical stability of T-matrix light scattering calculations for extreme particle shapes using the nullfield method with discrete sources," J. Quant. Spectrosc. Radiat. Transfer 112(11), 1679-1686 (2011).
-
(2011)
J. Quant. Spectrosc. Radiat. Transfer
, vol.112
, Issue.11
, pp. 1679-1686
-
-
Hellmers, J.1
Schmidt, V.2
Wriedt, T.3
-
33
-
-
84879630554
-
-
21 December 2012
-
A. Doicu, T. Wriedt, and Y. A. Eremin, "NFM-DS," (2010), http://www .scattport.org/index.php/programs-menu/t-matrix-codes-menu/239-nfm -ds (21 December 2012).
-
(2010)
NFM-DS
-
-
Doicu, A.1
Wriedt, T.2
Eremin, Y.A.3
-
34
-
-
34247467410
-
The discrete dipole approximation for simulation of light scattering by particles much larger than the wavelength
-
DOI 10.1016/j.jqsrt.2007.01.033, PII S0022407307000544
-
M. A. Yurkin, V. P. Maltsev, and A. G. Hoekstra, "The discrete dipole approximation for simulation of light scattering by particles much larger than the wavelength," J. Quant. Spectrosc. Radiat. Transfer 106(1-3), 546-557 (2007). (Pubitemid 46656927)
-
(2007)
Journal of Quantitative Spectroscopy and Radiative Transfer
, vol.106
, Issue.1-3
, pp. 546-557
-
-
Yurkin, M.A.1
Maltsev, V.P.2
Hoekstra, A.G.3
-
35
-
-
37549027288
-
Systematic comparison of the discrete dipole approximation and the finite difference time domain method for large dielectric scatterers
-
M. A. Yurkin et al., "Systematic comparison of the discrete dipole approximation and the finite difference time domain method for large dielectric scatterers," Opt. Express 15(26), 17902-17911 (2007).
-
(2007)
Opt. Express
, vol.15
, Issue.26
, pp. 17902-17911
-
-
Yurkin, M.A.1
-
36
-
-
77949573062
-
Comparison of the discrete dipole approximation and the discrete source method for simulation of light scattering by red blood cells
-
K. V. Gilev et al., "Comparison of the discrete dipole approximation and the discrete source method for simulation of light scattering by red blood cells," Opt. Express 18(6), 5681-5690 (2010).
-
(2010)
Opt. Express
, vol.18
, Issue.6
, pp. 5681-5690
-
-
Gilev, K.V.1
-
37
-
-
84857453770
-
Severe loss of precision in calculations of T-matrix integrals
-
W. R. C. Somerville, B. Auguié, and E. C. Le Ru, "Severe loss of precision in calculations of T-matrix integrals," J. Quant. Spectrosc. Radiat. Transfer 113(7), 524-535 (2012).
-
(2012)
J. Quant. Spectrosc. Radiat. Transfer
, vol.113
, Issue.7
, pp. 524-535
-
-
Somerville, W.R.C.1
Auguié, B.2
Le Ru, E.C.3
-
38
-
-
84879628316
-
An optimization method for solving the inverse Mie problem based on adaptive algorithm for construction of interpolating database
-
in press.
-
K. V. Gilev et al., "An optimization method for solving the inverse Mie problem based on adaptive algorithm for construction of interpolating database," J. Quant. Spectrosc. Radiat. Transfer, in press.
-
J. Quant. Spectrosc. Radiat. Transfer
-
-
Gilev, K.V.1
-
40
-
-
0000259005
-
Light scattering by red blood cells in ektacytometry: Fraunhofer versus anomalous diffraction
-
G. J. Streekstra et al., "Light scattering by red blood cells in ektacytometry: Fraunhofer versus anomalous diffraction," Appl. Opt. 32(13), 2266-2272 (1993).
-
(1993)
Appl. Opt.
, vol.32
, Issue.13
, pp. 2266-2272
-
-
Streekstra, G.J.1
-
42
-
-
0033569348
-
Use of mean platelet component to measure platelet activation on the ADVIA 120 haematology system
-
M. G. Macey et al., "Use of mean platelet component to measure platelet activation on the ADVIA 120 haematology system," Cytometry 38(5), 250-255 (1999).
-
(1999)
Cytometry
, vol.38
, Issue.5
, pp. 250-255
-
-
Macey, M.G.1
-
43
-
-
0242690425
-
Assessment of platelet activation in several different anticoagulants by the Advia 120 hematology system, fluorescence flow cytometry, and electron microscopy
-
C. E. Ahnadi et al., "Assessment of platelet activation in several different anticoagulants by the Advia® 120 Hematology System, fluorescence flow cytometry, and electron microscopy," Thromb. Haemostasis 90(5), 940-948 (2003). (Pubitemid 37427865)
-
(2003)
Thrombosis and Haemostasis
, vol.90
, Issue.5
, pp. 940-948
-
-
Ahnadi, C.E.1
Chapman, E.S.2
Lepine, M.3
Okrongly, D.4
Pujol-Moix, N.5
Hernandez, A.6
Boughrassa, F.7
Grant, A.M.8
-
44
-
-
0014828510
-
Observations on the change in shape of blood platelets brought about by adenosine diphosphate
-
G. V. R. Born, "Observations on the change in shape of blood platelets brought about by adenosine diphosphate," J. Physiol. 209(2), 487-511 (1970).
-
(1970)
J. Physiol.
, vol.209
, Issue.2
, pp. 487-511
-
-
Born, G.V.R.1
-
45
-
-
0029255479
-
A method for investigating the orientational behaviour of fibrous particles in gaseous flow
-
E. Hirst et al., "A method for investigating the orientational behaviour of fibrous particles in gaseous flow," Part. Syst. Charact. 12(1), 3-9 (1995).
-
(1995)
Part. Syst. Charact.
, vol.12
, Issue.1
, pp. 3-9
-
-
Hirst, E.1
-
46
-
-
85047686215
-
Size and shape determination of spheroidal scatterers using two-dimensional angle resolved scattering
-
M. Giacomelli et al., "Size and shape determination of spheroidal scatterers using two-dimensional angle resolved scattering," Opt. Express 18(14), 14616-14626 (2010).
-
(2010)
Opt. Express
, vol.18
, Issue.14
, pp. 14616-14626
-
-
Giacomelli, M.1
-
47
-
-
38849092118
-
The scanning flow cytometer modified for measurement of two-dimensional light-scattering pattern of individual particles
-
G. V. Dyatlov et al., "The scanning flow cytometer modified for measurement of two-dimensional light-scattering pattern of individual particles," Meas. Sci. Technol. 19(1), 015408 (2008).
-
(2008)
Meas. Sci. Technol.
, vol.19
, Issue.1
, pp. 015408
-
-
Dyatlov, G.V.1
|