메뉴 건너뛰기




Volumn 76, Issue , 2013, Pages 55-62

Comparison of Gallium-68 and Fluorine-18 imaging characteristics in positron emission tomography

Author keywords

Fluorine 18; Gallium 68; Image quantification; Positron emission tomography

Indexed keywords

ACTIVITY RECOVERY; FLUORINE-18; IMAGE QUANTIFICATION; IMAGING CHARACTERISTICS; MONTE CARLO CALCULATION; PHANTOM MEASUREMENTS; SMALL ANIMAL PET SCANNERS; SPATIAL RESOLUTION;

EID: 84878139630     PISSN: 09698043     EISSN: 18729800     Source Type: Journal    
DOI: 10.1016/j.apradiso.2012.06.034     Document Type: Article
Times cited : (195)

References (24)
  • 1
    • 58149210333 scopus 로고
    • PENELOPE: an algorithm for Monte Carlo simulation$n of the penetration and energy loss of electrons and positrons in matter
    • Baro J., Sempau J., Fernandez-Varea J.M., Salvat F. PENELOPE: an algorithm for Monte Carlo simulation$n of the penetration and energy loss of electrons and positrons in matter. Nucl. Instrum. Methods B. 1995, 100:31-46.
    • (1995) Nucl. Instrum. Methods B. , vol.100 , pp. 31-46
    • Baro, J.1    Sempau, J.2    Fernandez-Varea, J.M.3    Salvat, F.4
  • 3
    • 0012972621 scopus 로고
    • On the angular distribution of two-photon annihilation radiation
    • De Benedetti S., Cowan C.E., Konneker W.R., Primakoff H. On the angular distribution of two-photon annihilation radiation. Phys. Rev. 1950, 77:205-212.
    • (1950) Phys. Rev. , vol.77 , pp. 205-212
    • De Benedetti, S.1    Cowan, C.E.2    Konneker, W.R.3    Primakoff, H.4
  • 4
    • 77950951879 scopus 로고    scopus 로고
    • Image-quality assessment for several positron emitters using the NEMA NU 4-2008 standards in the Siemens Inveon small-animal PET scanner
    • Disselhorst J.A., Brom M., Laverman P., Slump C.H., Boerman O.C., Oyen W.J., Gotthardt M., Visser E.P. Image-quality assessment for several positron emitters using the NEMA NU 4-2008 standards in the Siemens Inveon small-animal PET scanner. J. Nucl. Med. 2010, 51:610-617.
    • (2010) J. Nucl. Med. , vol.51 , pp. 610-617
    • Disselhorst, J.A.1    Brom, M.2    Laverman, P.3    Slump, C.H.4    Boerman, O.C.5    Oyen, W.J.6    Gotthardt, M.7    Visser, E.P.8
  • 6
    • 44249106830 scopus 로고    scopus 로고
    • 68Ga-PET: a powerful generator-based alternative to cyclotron-based PET radiopharmaceuticals
    • 68Ga-PET: a powerful generator-based alternative to cyclotron-based PET radiopharmaceuticals. Contrast Media Mol. Imaging 2008, 3:53-63.
    • (2008) Contrast Media Mol. Imaging , vol.3 , pp. 53-63
    • Fani, M.1    Andre, J.P.2    Maecke, H.R.3
  • 8
    • 84878156258 scopus 로고    scopus 로고
    • International Bureau of Weights and Measures, BIPM
    • Table of Radionuclides. Monographie BIPM-5. Henri Becquerel National Laboratory.
    • International Bureau of Weights and Measures, BIPM, 2012. Table of Radionuclides. Monographie BIPM-5. Henri Becquerel National Laboratory.
    • (2012)
  • 9
    • 84891728045 scopus 로고    scopus 로고
    • Physical performance comparison of Ga-68 and F-18 in small animal PET system
    • Kim Joong Hyun, Lee Jae Sung, Kim Jin Su, Chung June-Key, Lee Myung Chul, Lee Dong Soo Physical performance comparison of Ga-68 and F-18 in small animal PET system. J. Nucl. Med. 2010, 51:1423.
    • (2010) J. Nucl. Med. , vol.51 , pp. 1423
    • Kim, J.H.1    Lee, J.S.2    Kim, J.S.3    Chung, J.-K.4    Lee, M.C.5    Lee, D.S.6
  • 10
    • 67349166962 scopus 로고    scopus 로고
    • Quantitative small animal PET imaging with nonconventional nuclides
    • Liu X., Laforest R. Quantitative small animal PET imaging with nonconventional nuclides. Nucl. Med. Biol. 2009, 36:551-559.
    • (2009) Nucl. Med. Biol. , vol.36 , pp. 551-559
    • Liu, X.1    Laforest, R.2
  • 11
    • 0018843122 scopus 로고
    • A new generator for ionic gallium-68
    • Loc'h C., Mazièré B., Comar D. A new generator for ionic gallium-68. J. Nucl. Med. 1980, 21:171-173.
    • (1980) J. Nucl. Med. , vol.21 , pp. 171-173
    • Loc'h, C.1    Mazièré, B.2    Comar, D.3
  • 13
    • 0022497731 scopus 로고
    • Quantitative measurement of regional pulmonary blood flow with positron emission tomography
    • Mintun M.A., Ter-Pogossian M.M., Green M.A., Lich L.L., Schuster D.P. Quantitative measurement of regional pulmonary blood flow with positron emission tomography. J. Appl. Physiol. 1986, 60:317-326.
    • (1986) J. Appl. Physiol. , vol.60 , pp. 317-326
    • Mintun, M.A.1    Ter-Pogossian, M.M.2    Green, M.A.3    Lich, L.L.4    Schuster, D.P.5
  • 14
    • 79960836282 scopus 로고    scopus 로고
    • Fundamental limits of spatial resolution in PET
    • Moses W.W. Fundamental limits of spatial resolution in PET. Nucl. Instrum. Methods Phys. Res. A 2011, 21:236-240.
    • (2011) Nucl. Instrum. Methods Phys. Res. A , vol.21 , pp. 236-240
    • Moses, W.W.1
  • 15
    • 0030696927 scopus 로고    scopus 로고
    • Alternative positron emission tomography with non-conventional positron emitters: effects of their physical properties on image quality and potential clinical applications
    • Pagani M., Stone-Elander S., Larsson S.A. Alternative positron emission tomography with non-conventional positron emitters: effects of their physical properties on image quality and potential clinical applications. Eur. J. Nucl. Med. 1997, 24:1301-1327.
    • (1997) Eur. J. Nucl. Med. , vol.24 , pp. 1301-1327
    • Pagani, M.1    Stone-Elander, S.2    Larsson, S.A.3
  • 18
    • 1642430605 scopus 로고    scopus 로고
    • Positron flight in human tissues and its influence on PET image spatial resolution
    • Sanchez-Crespo A., Andreo P., Larsson S.A. Positron flight in human tissues and its influence on PET image spatial resolution. Eur. J. Nucl. Med. Mol. Imaging 2004, 31:44-51.
    • (2004) Eur. J. Nucl. Med. Mol. Imaging , vol.31 , pp. 44-51
    • Sanchez-Crespo, A.1    Andreo, P.2    Larsson, S.A.3
  • 19
    • 33746393825 scopus 로고    scopus 로고
    • The influence of photon depth of interaction and non-collinear spread of annihilation photons on PET image spatial resolution
    • Sanchez-Crespo A., Larsson S.A. The influence of photon depth of interaction and non-collinear spread of annihilation photons on PET image spatial resolution. Eur. J. Nucl. Med. Mol. Imaging 2006, 33:940-947.
    • (2006) Eur. J. Nucl. Med. Mol. Imaging , vol.33 , pp. 940-947
    • Sanchez-Crespo, A.1    Larsson, S.A.2
  • 20
    • 34250315240 scopus 로고    scopus 로고
    • Partial-volume effect in PET tumour imaging
    • Soret M., Bacharach S.L., Buvat I. Partial-volume effect in PET tumour imaging. J. Nucl. Med. 2007, 48:932-945.
    • (2007) J. Nucl. Med. , vol.48 , pp. 932-945
    • Soret, M.1    Bacharach, S.L.2    Buvat, I.3
  • 21
    • 0025845450 scopus 로고
    • The applications of PET in clinical oncology
    • Strauss L.G., Conti P.S. The applications of PET in clinical oncology. J. Nucl. Med. 1991, 32:623-648.
    • (1991) J. Nucl. Med. , vol.32 , pp. 623-648
    • Strauss, L.G.1    Conti, P.S.2
  • 22
    • 0027958185 scopus 로고
    • Gallium-67/gallium-68-[DFO]-Octreotide-A potential radiopharmaceutical for PET imaging of somatostatin receptor-positive tumors: synthesis and radiolabeling in vitro and preliminary in vivo studies
    • Smith-Jones P.M., Stolz B., Bruns C., Albert R., Reist H.W., Fridrich R., Mäcke H.R. Gallium-67/gallium-68-[DFO]-Octreotide-A potential radiopharmaceutical for PET imaging of somatostatin receptor-positive tumors: synthesis and radiolabeling in vitro and preliminary in vivo studies. J. Nucl. Med. 1994, 35:317-325.
    • (1994) J. Nucl. Med. , vol.35 , pp. 317-325
    • Smith-Jones, P.M.1    Stolz, B.2    Bruns, C.3    Albert, R.4    Reist, H.W.5    Fridrich, R.6    Mäcke, H.R.7
  • 23
    • 43249131270 scopus 로고    scopus 로고
    • PET imaging of biomolecules using metal-DOTA complexes: a new collaborative challenge by chemists, biologists, and physicians for future diagnostics and exploration of in vivo dynamics
    • Tanaka K., Fukase K. PET imaging of biomolecules using metal-DOTA complexes: a new collaborative challenge by chemists, biologists, and physicians for future diagnostics and exploration of in vivo dynamics. Org. Biomol. Chem. 2008, 6:815-828.
    • (2008) Org. Biomol. Chem. , vol.6 , pp. 815-828
    • Tanaka, K.1    Fukase, K.2
  • 24
    • 80255137722 scopus 로고    scopus 로고
    • Effect of the positron range on the spatial resolution of a new generation pre-clinical PETscanner using F-18, Ga-68, Zr-89 and I-124
    • van Dalen J., Visser E., Laverman P., Vogel W., Oyen W., Corstens F., Boerman O. Effect of the positron range on the spatial resolution of a new generation pre-clinical PETscanner using F-18, Ga-68, Zr-89 and I-124. J. Nucl. Med. 2008, 49:404.
    • (2008) J. Nucl. Med. , vol.49 , pp. 404
    • van Dalen, J.1    Visser, E.2    Laverman, P.3    Vogel, W.4    Oyen, W.5    Corstens, F.6    Boerman, O.7


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.