Volumn 69, Issue 6, 2013, Pages 1553-1563

Multidirectional high-moment encoding in phase contrast MRI

Author keywords

high moment; multiple VENC; phase contrast; velocity quantitation

Indexed keywords

ANGIOGRAPHY; BIOMEDICAL SIGNAL PROCESSING; EFFICIENCY; MAGNETIC RESONANCE; MAGNETIC RESONANCE IMAGING; PHASE MEASUREMENT; SIGNAL ENCODING; VELOCITY;

EID: 84878112858     PISSN: 07403194     EISSN: 15222594     Source Type: Journal    
DOI: 10.1002/mrm.24390     Document Type: Article
Times cited : (23)

References (18)
  • 1
    • 0026876771 scopus 로고
    • Analysis of encoding efficiency in MR imaging of velocity magnitude and direction
    • Conturo TE, Robinson BH,. Analysis of encoding efficiency in MR imaging of velocity magnitude and direction. Magn Reson Med 1992; 25: 233-247.
    • (1992) Magn Reson Med , vol.25 , pp. 233-247
    • Conturo, T.E.1    Robinson, B.H.2
  • 3
    • 75749111626 scopus 로고    scopus 로고
    • Improved SNR in phase contrast velocimetry with five-point balanced flow encoding
    • Johnson KM, Markl M,. Improved SNR in phase contrast velocimetry with five-point balanced flow encoding. Magn Reson Med 2010; 63: 349-355.
    • (2010) Magn Reson Med , vol.63 , pp. 349-355
    • Johnson, K.M.1    Markl, M.2
  • 5
    • 0028957906 scopus 로고
    • Fast three dimensional magnetic resonance imaging
    • Irarrazabal P, Nishimura DG,. Fast three dimensional magnetic resonance imaging. Magn Reson Med 1995; 33: 656-662.
    • (1995) Magn Reson Med , vol.33 , pp. 656-662
    • Irarrazabal, P.1    Nishimura, D.G.2
  • 6
    • 0028854765 scopus 로고
    • Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio
    • Lee AT, Pike GB, Pelc NJ,. Three-point phase-contrast velocity measurements with increased velocity-to-noise ratio. Magn Reson Med 1995; 33: 122-126.
    • (1995) Magn Reson Med , vol.33 , pp. 122-126
    • Lee, A.T.1    Pike, G.B.2    Pelc, N.J.3
  • 7
    • 0037372021 scopus 로고    scopus 로고
    • A simple measure of flow disorder and wall shear stress in phase contrast MRI
    • Pipe JG,. A simple measure of flow disorder and wall shear stress in phase contrast MRI. Magn Reson Med 2003; 49: 543-550.
    • (2003) Magn Reson Med , vol.49 , pp. 543-550
    • Pipe, J.G.1
  • 8
    • 0031397265 scopus 로고    scopus 로고
    • Multistep phase difference phase contrast imaging
    • Lamothe MJ, Rutt BK,. Multistep phase difference phase contrast imaging. J Magn Reson Imaging 1997; 7: 838-842.
    • (1997) J Magn Reson Imaging , vol.7 , pp. 838-842
    • Lamothe, M.J.1    Rutt, B.K.2
  • 9
    • 0034794323 scopus 로고    scopus 로고
    • Advances in sensitivity encoding with arbitrary k-space trajectories
    • Pruessmann KP, Weiger M, Bornert P, Boesiger P,. Advances in sensitivity encoding with arbitrary k-space trajectories. Magn Reson Med 2001; 46: 638-651.
    • (2001) Magn Reson Med , vol.46 , pp. 638-651
    • Pruessmann, K.P.1    Weiger, M.2    Bornert, P.3    Boesiger, P.4
  • 10
    • 36849088522 scopus 로고    scopus 로고
    • Sparse MRI: The application of compressed sensing for rapid MR imaging
    • Lustig M, Donoho D, Pauly JM,. Sparse MRI: the application of compressed sensing for rapid MR imaging. Magn Reson Med 2007; 58: 1182-1195.
    • (2007) Magn Reson Med , vol.58 , pp. 1182-1195
    • Lustig, M.1    Donoho, D.2    Pauly, J.M.3
  • 11
    • 0025102147 scopus 로고
    • Signal-to-noise in phase angle reconstruction: Dynamic range extension using phase reference offsets
    • Conturo TE, Smith GD,. Signal-to-noise in phase angle reconstruction: dynamic range extension using phase reference offsets. Magn Reson Med 1990; 15: 420-437.
    • (1990) Magn Reson Med , vol.15 , pp. 420-437
    • Conturo, T.E.1    Smith, G.D.2
  • 12
    • 0035038227 scopus 로고    scopus 로고
    • Comparison of gradient encoding schemes for diffusion-tensor MRI
    • Hasan KM, Parker DL, Alexander AL,. Comparison of gradient encoding schemes for diffusion-tensor MRI. J Magn Reson Imaging 2001; 13: 769-780.
    • (2001) J Magn Reson Imaging , vol.13 , pp. 769-780
    • Hasan, K.M.1    Parker, D.L.2    Alexander, A.L.3
  • 14
    • 0028904705 scopus 로고
    • A velocity k-space analysis of flow effects in echo-planar and spiral imaging
    • Nishimura DG, Irarrazabal P, Meyer CH,. A velocity k-space analysis of flow effects in echo-planar and spiral imaging. Magn Reson Med 1995; 33: 549-56.
    • (1995) Magn Reson Med , vol.33 , pp. 549-556
    • Nishimura, D.G.1    Irarrazabal, P.2    Meyer, C.H.3
  • 15
    • 0027093023 scopus 로고
    • Projection reconstruction techniques for reduction of motion effects in MRI
    • Glover GH, Pauly JM,. Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 1992; 28: 275-289.
    • (1992) Magn Reson Med , vol.28 , pp. 275-289
    • Glover, G.H.1    Pauly, J.M.2
  • 17
    • 0027956368 scopus 로고
    • Reconstructions of phase contrast, phased array multicoil data
    • Bernstein MA, Grgic M, Brosnan TJ, Pelc NJ,. Reconstructions of phase contrast, phased array multicoil data. Magn Reson Med 1994; 32: 330-334.
    • (1994) Magn Reson Med , vol.32 , pp. 330-334
    • Bernstein, M.A.1    Grgic, M.2    Brosnan, T.J.3    Pelc, N.J.4
  • 18
    • 84872862026 scopus 로고    scopus 로고
    • Improved MR phase-contrast velocimetry using a novel nine-point balanced motion-encoding scheme with increased robustness to eddy current effects
    • doi: 10.1002/mrm.24226
    • Espe EKS, Aronsen JM, Skrbic B, Skulberg VM, Schneider JE, Sejersted OM, Zhang L, Sjaastad I,. Improved MR phase-contrast velocimetry using a novel nine-point balanced motion-encoding scheme with increased robustness to eddy current effects. Magn Reson Med 2012. doi: 10.1002/mrm.24226.
    • (2012) Magn Reson Med
    • Espe, E.K.S.1    Aronsen, J.M.2    Skrbic, B.3    Skulberg, V.M.4    Schneider, J.E.5    Sejersted, O.M.6    Zhang, L.7    Sjaastad, I.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.