메뉴 건너뛰기




Volumn 8583, Issue , 2013, Pages

Performance assessment of time-domain optical brain imagers: A multi-laboratory study

Author keywords

instrumentation; performance comparison; Time domain optical brain imaging; tissue like phantoms

Indexed keywords

ABSORPTION CO-EFFICIENT; DIFFUSE OPTICAL IMAGING; INSTRUMENTATION; METHODS OF DATA ANALYSIS; OPTICAL BRAIN IMAGING; PERFORMANCE COMPARISON; TIME-RESOLVED REFLECTANCE; TISSUE-LIKE PHANTOM;

EID: 84878076069     PISSN: 16057422     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1117/12.2002438     Document Type: Conference Paper
Times cited : (11)

References (18)
  • 1
    • 84863968388 scopus 로고    scopus 로고
    • Introduction: Feature issue on phantoms for the performance evaluation and validation of optical medical imaging devices
    • Hwang, J., Ramella-Roman, J.C., Nordstrom, R., "Introduction: feature issue on phantoms for the performance evaluation and validation of optical medical imaging devices," Biomed. Opt. Express 3, 1399-403 (2012).
    • (2012) Biomed. Opt. Express , vol.3 , pp. 1399-1403
    • Hwang, J.1    Ramella-Roman, J.C.2    Nordstrom, R.3
  • 5
    • 79551669199 scopus 로고    scopus 로고
    • Intralipid: Towards a diffusive reference standard for optical tissue phantoms
    • Di Ninni, P., Martelli, F., Zaccanti, G., "Intralipid: towards a diffusive reference standard for optical tissue phantoms," Phys. Med. Biol. 56, N21-8 (2011).
    • (2011) Phys. Med. Biol. , vol.56
    • Di Ninni, P.1    Martelli, F.2    Zaccanti, G.3
  • 6
    • 78650555808 scopus 로고    scopus 로고
    • The use of India ink in tissue-simulating phantoms
    • Di Ninni, P., Martelli, F., Zaccanti, G., "The use of India ink in tissue-simulating phantoms," Opt. Express 18, 26854-65 (2010).
    • (2010) Opt. Express , vol.18 , pp. 26854-26865
    • Di Ninni, P.1    Martelli, F.2    Zaccanti, G.3
  • 11
    • 33745121603 scopus 로고    scopus 로고
    • A multi-channel time-resolved system for functional near infrared spectroscopy
    • Contini, D., Torricelli, A., Pifferi, A., Spinelli, L., Paglia, F. and Cubeddu R., "A multi-channel time-resolved system for functional near infrared spectroscopy," Opt. Express 14, 5418-5432 (2006).
    • (2006) Opt. Express , vol.14 , pp. 5418-5432
    • Contini, D.1    Torricelli, A.2    Pifferi, A.3    Spinelli, L.4    Paglia, F.5    Cubeddu, R.6
  • 13
    • 34547917912 scopus 로고    scopus 로고
    • Time-resolved optical imager for assessment of cerebral oxygenation
    • Kacprzak, M., Liebert, A., Sawosz, P. Zolek, N. and Maniewski, R., "Time-resolved optical imager for assessment of cerebral oxygenation," J. Biomed. Opt. 12, 034019 (2007).
    • (2007) J. Biomed. Opt. , vol.12 , pp. 034019
    • Kacprzak, M.1    Liebert, A.2    Sawosz, P.3    Zolek, N.4    Maniewski, R.5
  • 16
    • 0032209395 scopus 로고    scopus 로고
    • Monte Carlo procedure for investigating lightpropagation and imaging of highly scattering media
    • Sassaroli, A., Blumetti, C., Martelli, F., Alianelli, L., Contini, D., Ismaelli, A. and Zaccanti, G., "Monte Carlo procedure for investigating lightpropagation and imaging of highly scattering media," Appl. Opt. 37, 7392-7400 (1998).
    • (1998) Appl. Opt. , vol.37 , pp. 7392-7400
    • Sassaroli, A.1    Blumetti, C.2    Martelli, F.3    Alianelli, L.4    Contini, D.5    Ismaelli, A.6    Zaccanti, G.7
  • 17
    • 77952053614 scopus 로고    scopus 로고
    • Light diffusion in N-layered turbid media: frequency and time domains
    • Liemert, A. and Kienle, A. "Light diffusion in N-layered turbid media: frequency and time domains," J. Biomed. Opt. 15, 025002 (2010).
    • (2010) J. Biomed. Opt. , vol.15 , pp. 025002
    • Liemert, A.1    Kienle, A.2
  • 18
    • 0141958753 scopus 로고    scopus 로고
    • Evaluation of optical properties of highly scattering media by moments of distributions of times of flight of photons
    • Liebert, A., Wabnitz, H., Grosenick, D., Möller, M. and Macdonald, R., "Evaluation of optical properties of highly scattering media by moments of distributions of times of flight of photons," Appl. Opt. 42, 5785-5792 (2003).
    • (2003) Appl. Opt. , vol.42 , pp. 5785-5792
    • Liebert, A.1    Wabnitz, H.2    Grosenick, D.3    Möller, M.4    Macdonald, R.5