메뉴 건너뛰기




Volumn 4, Issue 1, 2013, Pages 74-78

Anterior segment opticalcoherence tomography: Assisted topographic corneal epithelial thickness distribution imaging of a keratoconus patient

Author keywords

Anterior segment optical coherence tomography; Epithelial imaging; Keratoconus; Pentacam HR

Indexed keywords

ADULT; ANTERIOR SEGMENT OPTICAL COHERENCE TOMOGRAPHY; ARTICLE; CASE REPORT; CLINICAL FEATURE; CORNEA EPITHELIUM; CORNEA THICKNESS; HUMAN; IMAGE ANALYSIS; KERATOCONUS; MALE; OPTICAL COHERENCE TOMOGRAPHY; OPTICAL COHERENCE TOMOGRAPHY DEVICE; OUTCOME ASSESSMENT; PRIORITY JOURNAL; VISUAL ACUITY; VISUAL SYSTEM PARAMETERS; CLINICAL EFFECTIVENESS; COMPUTED TOMOGRAPHY SCANNER; CORNEAL EPITHELIAL THICKNESS DISTRIBUTION; PATIENT SAFETY; PREDICTION;

EID: 84877978807     PISSN: None     EISSN: 16632699     Source Type: Journal    
DOI: 10.1159/000350630     Document Type: Article
Times cited : (35)

References (4)
  • 1
    • 84863428442 scopus 로고    scopus 로고
    • Correlation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; Is overall epithelial thickness a very early ectasia prognostic factor?
    • Kanellopoulos AJ, Aslanides I, Asimellis G: Correlation between epithelial thickness in normal corneas, untreated ectatic corneas, and ectatic corneas previously treated with CXL; is overall epithelial thickness a very early ectasia prognostic factor? Clin Ophthalmol 2012;6:789-800.
    • (2012) Clin Ophthalmol , vol.6 , pp. 789-800
    • Kanellopoulos, A.J.1    Aslanides, I.2    Asimellis, G.3
  • 2
    • 84877945097 scopus 로고    scopus 로고
    • Correlation between central corneal thickness, anterior chamber depth, and corneal keratometry as measured by Oculyzer II and WaveLight OB820 in preoperative cataract surgery patients
    • Kanellopoulos AJ, Asimellis G: Correlation between central corneal thickness, anterior chamber depth, and corneal keratometry as measured by Oculyzer II and WaveLight OB820 in preoperative cataract surgery patients. J Refract Surg 2012;22:1-6.
    • (2012) J Refract Surg , vol.22 , pp. 1-6
    • Kanellopoulos, A.J.1    Asimellis, G.2
  • 3
    • 33646712980 scopus 로고    scopus 로고
    • Corneal and epithelial thickness in keratoconus: A comparison of ultrasonic pachymetry, Orbscan II, and optical coherence tomography
    • Haque S, Simpson T, Jones L: Corneal and epithelial thickness in keratoconus: a comparison of ultrasonic pachymetry, Orbscan II, and optical coherence tomography. J Refract Surg 2006;22:486-493. (Pubitemid 43736477)
    • (2006) Journal of Refractive Surgery , vol.22 , Issue.5 , pp. 486-493
    • Haque, S.1    Simpson, T.2    Jones, L.3
  • 4
    • 33745261640 scopus 로고    scopus 로고
    • The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography
    • Sin S, Simpson TL: The repeatability of corneal and corneal epithelial thickness measurements using optical coherence tomography. Optom Vis Sci 2006;83:360-365.
    • (2006) Optom Vis Sci , vol.83 , pp. 360-365
    • Sin, S.1    Simpson, T.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.