메뉴 건너뛰기




Volumn 8, Issue 3, 2013, Pages

A new PET prototype for proton therapy: Comparison of data and Monte Carlo simulations

Author keywords

Gamma camera, SPECT, PET PET CT, coronary CT angiography (CTA); Instrumentation for hadron therapy; Instrumentation for heavy ion therapy

Indexed keywords

ANNIHILATION PHOTONS; CORONARY CT ANGIOGRAPHIES; FRONT END ELECTRONICS; HADRON THERAPY; HEAVY-ION THERAPY; MONTE CARLO SIMULATIONS; POSITION SENSITIVE PHOTOMULTIPLIERS; THERAPEUTIC TREATMENTS;

EID: 84877777145     PISSN: None     EISSN: 17480221     Source Type: Journal    
DOI: 10.1088/1748-0221/8/03/C03021     Document Type: Article
Times cited : (17)

References (11)
  • 1
    • 3342974692 scopus 로고    scopus 로고
    • Charged hadron tumour therapy monitoring by means of PET
    • 10.1016/j.nima.2004.03.128 0168-9002
    • W. Enghardt et al. 2004 Charged hadron tumour therapy monitoring by means of PET, Nucl. Instrum. Meth. A 525 284
    • (2004) Nucl. Instrum. Meth. A , vol.525 , pp. 284
    • Enghardt, W.1
  • 2
    • 48349094227 scopus 로고    scopus 로고
    • Quantitative assessment of the physical potential of proton beam range verification with PET/CT
    • 10.1088/0031-9155/53/15/009 0031-9155 009
    • A. Knopf et al. 2008 Quantitative assessment of the physical potential of proton beam range verification with PET/CT, Phys. Med. Biol. 53 4137
    • (2008) Phys. Med. Biol. , vol.53 , Issue.15 , pp. 4137
    • Knopf, A.1
  • 3
    • 79961087845 scopus 로고    scopus 로고
    • Extension and validation of an analytical model for in vivo PET verification of proton therapy - A phantom and clinical study
    • 10.1088/0031-9155/56/16/001 0031-9155 001
    • F. Attanasi et al. 2011 Extension and validation of an analytical model for in vivo PET verification of proton therapy - a phantom and clinical study, Phys. Med. Biol. 56 5079
    • (2011) Phys. Med. Biol. , vol.56 , Issue.16 , pp. 5079
    • Attanasi, F.1
  • 4
    • 60449089438 scopus 로고    scopus 로고
    • A PET Prototype for ''In-Beam'' Monitoring of Proton Therapy
    • 10.1109/TNS.2008.2008306 0018-9499
    • S. Vecchio 2009 A PET Prototype for ''In-Beam'' Monitoring of Proton Therapy, IEEE Trans. Nucl. Sci. 56 51
    • (2009) IEEE Trans. Nucl. Sci. , vol.56 , pp. 51
    • Vecchio, S.1
  • 5
    • 84877775300 scopus 로고    scopus 로고
    • www.cnao.it
  • 6
    • 34248227781 scopus 로고    scopus 로고
    • The FLUKA code: Description and benchmarking
    • 10.1063/1.2720455 0094-243X
    • G. Battistoni et al. 2007 The FLUKA code: description and benchmarking, AIP Conf. Proc. 896 31
    • (2007) AIP Conf. Proc. , vol.896 , pp. 31
    • Battistoni, G.1
  • 8
    • 84858777195 scopus 로고    scopus 로고
    • The status of CNAO
    • 10.1140/epjp/i2011-11078-8 2190-5444
    • S. Rossi 2011 The status of CNAO, Eur. Phys. J. Plus 126 78
    • (2011) Eur. Phys. J. Plus , vol.126 , Issue.8 , pp. 78
    • Rossi, S.1
  • 9
    • 79959374404 scopus 로고    scopus 로고
    • Reprogrammable Acquisition Architecture for Dedicated Positron Emission Tomography
    • 10.1109/TNS.2011.2113193 0018-9499
    • G. Sportelli et al. 2011 Reprogrammable Acquisition Architecture for Dedicated Positron Emission Tomography, IEEE Trans. Nucl. Sci. 58 695
    • (2011) IEEE Trans. Nucl. Sci. , vol.58 , pp. 695
    • Sportelli, G.1
  • 10
    • 84872032645 scopus 로고    scopus 로고
    • Massively parallelizable LM-OSEM using an elliptical Gaussian model
    • 10.1118/1.4771936 0094-2405
    • G. Sportelli et al. 2013 Massively parallelizable LM-OSEM using an elliptical Gaussian model, Med. Phys. 40 (1)
    • (2013) Med. Phys. , vol.40
    • Sportelli, G.1
  • 11
    • 84887817599 scopus 로고    scopus 로고
    • Full in-beam PET measurements of 62 MeV protons onto a PMMA target
    • 10.1016/j.nima.2012.08.100
    • G. Sportelli et al. 2012 Full in-beam PET measurements of 62 MeV protons onto a PMMA target, Nucl. Instrum. Meth. A, in press
    • (2012) Nucl. Instrum. Meth.
    • Sportelli, G.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.