메뉴 건너뛰기




Volumn 8, Issue 3, 2013, Pages

Energy resolving CT systems using Medipix2 and MHSP detectors

Author keywords

Computerized Tomography (CT) and Computed Radiography (CR); Micropattern gaseous detectors (MSGC, GEM, THGEM, RETHGEM, MHSP, MICROPIC, MICROMEGAS, InGrid, etc); Pixelated detectors and associated VLSI electronics; X ray detectors

Indexed keywords

COMPUTED RADIOGRAPHY; ENERGY INFORMATION; ENERGY-RESOLVING DETECTORS; GASEOUS DETECTORS; MATERIAL DECOMPOSITION; VLSI ELECTRONICS; X-RAY COMPUTED TOMOGRAPHY; X-RAY DETECTOR;

EID: 84877752458     PISSN: None     EISSN: 17480221     Source Type: Journal    
DOI: 10.1088/1748-0221/8/03/C03022     Document Type: Article
Times cited : (7)

References (16)
  • 3
    • 4544325396 scopus 로고    scopus 로고
    • The influence of energy weighting on X-ray imaging quality
    • 10.1016/j.nima.2004.05.076 0168-9002
    • J. Giersch, D. Niederlöhner and G. Anton 2004 The influence of energy weighting on X-ray imaging quality, Nucl. Instrum. Meth. A 531 68
    • (2004) Nucl. Instrum. Meth. A , vol.531 , pp. 68
    • Giersch, J.1    Niederlöhner, D.2    Anton, G.3
  • 4
    • 44649180983 scopus 로고    scopus 로고
    • Material resolving X-ray imaging using spectrum reconstruction with Medipix2
    • 10.1016/j.nima.2008.03.017 0168-9002
    • M. Firsching, P. Takoukam Talla, T. Michel and G. Anton 2008 Material resolving X-ray imaging using spectrum reconstruction with Medipix2, Nucl. Instrum. Meth. A 591 19
    • (2008) Nucl. Instrum. Meth. A , vol.591 , pp. 19
    • Firsching, M.1    Takoukam Talla, P.2    Michel, T.3    Anton, G.4
  • 5
    • 79959458638 scopus 로고    scopus 로고
    • Multi-energy X-ray imaging as a quantitative method for materials characterization
    • 10.1002/adma.201004111
    • M. Firsching, F. Nachtrab, N. Uhlmann and R. Hanke 2011 Multi-energy X-ray imaging as a quantitative method for materials characterization, Adv. Mater. 23 2655
    • (2011) Adv. Mater. , vol.23 , pp. 2655
    • Firsching, M.1    Nachtrab, F.2    Uhlmann, N.3    Hanke, R.4
  • 6
    • 0036815755 scopus 로고    scopus 로고
    • Medipix2: A 64-k pixel readout chip with 55-μm square elements working in single photon counting mode
    • 10.1109/TNS.2002.803788 0018-9499
    • X. Llopart, M. Campbell, R. Dinapoli, D. San Segundo and E. Pernigotti 2002 Medipix2: a 64-k pixel readout chip with 55-μm square elements working in single photon counting mode, IEEE Trans. Nucl. Sci. 49 2279
    • (2002) IEEE Trans. Nucl. Sci. , vol.49 , pp. 2279
    • Llopart, X.1    Campbell, M.2    Dinapoli, R.3    San Segundo, D.4    Pernigotti, E.5
  • 7
    • 79952825436 scopus 로고    scopus 로고
    • Energy weighting technique in quantum computed tomography using a MPGD
    • 1748-0221 C02002
    • L.F.N.D. Carramate et al. 2011 Energy weighting technique in quantum computed tomography using a MPGD, JINST 6 C02002
    • (2011) JINST , vol.6 , Issue.2 , pp. 02002
    • Carramate, L.F.N.D.1
  • 8
    • 77953698366 scopus 로고    scopus 로고
    • Energy weighting in a 2D-MHSP X-ray single photon detector
    • 10.1109/TNS.2010.2044806 0018-9499
    • C.A.B. Oliveira et al. 2010 Energy weighting in a 2D-MHSP X-ray single photon detector, IEEE Trans. Nucl. Sci. 57 938
    • (2010) IEEE Trans. Nucl. Sci. , vol.57 , pp. 938
    • Oliveira, C.A.B.1
  • 9
    • 67650168121 scopus 로고    scopus 로고
    • Contrast agent recognition in small animal CT using Medipix2 detector
    • 10.1016/j.nima.2009.03.141 0168-9002
    • M. Firsching et al. 2009 Contrast agent recognition in small animal CT using Medipix2 detector, Nucl. Instrum. Meth. A 607 179
    • (2009) Nucl. Instrum. Meth. A , vol.607 , pp. 179
    • Firsching, M.1
  • 10
    • 57649101015 scopus 로고    scopus 로고
    • Reconstruction of X-ray spectra with the energy sensitive photon counting detector Medipix2
    • 10.1016/j.nima.2008.09.049 0168-9002
    • T. Michel et al. 2009 Reconstruction of X-ray spectra with the energy sensitive photon counting detector Medipix2, Nucl. Instrum. Meth. A 598 510
    • (2009) Nucl. Instrum. Meth. A , vol.598 , pp. 510
    • Michel, T.1
  • 12
    • 11244310646 scopus 로고    scopus 로고
    • Geometric misalignment and calibration in cone-beam tomography
    • 10.1118/1.1803792 0094-2405
    • L. von Smekal, M. Kachelrieß, E. Stepina and W.A. Kalender 2004 Geometric misalignment and calibration in cone-beam tomography, Med. Phys. 31 3242
    • (2004) Med. Phys. , vol.31 , pp. 3242
    • Von Smekal, L.1    Kachelrieß, M.2    Stepina, E.3    Kalender, W.A.4
  • 13
    • 84856823329 scopus 로고    scopus 로고
    • Multi-slice quantum Computed Tomography system using a MHSP
    • 1748-0221 C01106
    • L.F.N.D. Carramate et al. 2012 Multi-slice quantum Computed Tomography system using a MHSP, JINST 7 C01106
    • (2012) JINST , vol.7 , Issue.1 , pp. 01106
    • Carramate, L.F.N.D.1
  • 14
    • 53349153312 scopus 로고    scopus 로고
    • Single photon counting x-ray imaging system using a Micro Hole and Strip Plate
    • 10.1109/TNS.2008.2001423 0018-9499
    • H.N. da Luz et al. 2008 Single photon counting x-ray imaging system using a Micro Hole and Strip Plate, IEEE Trans. Nucl. Sci. 55 2341
    • (2008) IEEE Trans. Nucl. Sci. , vol.55 , pp. 2341
    • Da Luz, H.N.1
  • 15
    • 34548207304 scopus 로고    scopus 로고
    • High-rate operation of the Micro-Hole and Strip Plate gas detector
    • 10.1016/j.nima.2007.05.179 0168-9002
    • J.F.C.A. Veloso et al. 2007 High-rate operation of the Micro-Hole and Strip Plate gas detector, Nucl. Instrum. Meth. A 580 362
    • (2007) Nucl. Instrum. Meth. A , vol.580 , pp. 362
    • Veloso, J.F.C.A.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.