메뉴 건너뛰기




Volumn 26, Issue 3, 2013, Pages 406-411

Automated estimation of abdominal effective diameter for body size normalization of CT dose

Author keywords

Body imaging; Computed tomography; Image analysis; Quality control; Radiation dose

Indexed keywords

AUTOMATED ESTIMATION; BODY IMAGING; CLOSE APPROXIMATION; COMPUTED TOMOGRAPHY; DOSE-LENGTH PRODUCTS; EFFECTIVE DIAMETER; GENERAL ELECTRICS; MEAN ABSOLUTE ERROR;

EID: 84877744437     PISSN: 08971889     EISSN: 1618727X     Source Type: Journal    
DOI: 10.1007/s10278-012-9525-z     Document Type: Article
Times cited : (15)

References (9)
  • 1
    • 84928096446 scopus 로고    scopus 로고
    • Automated extraction of radiation dose information for CT examinations
    • 21040869 10.1016/j.jacr.2010.06.026
    • Cook TS, Zimmerman S, Maidment AD, Kim W, Boonn WW: Automated extraction of radiation dose information for CT examinations. J Am Coll Radiol 7:871-877, 2010
    • (2010) J Am Coll Radiol , vol.7 , pp. 871-877
    • Cook, T.S.1    Zimmerman, S.2    Maidment, A.D.3    Kim, W.4    Boonn, W.W.5
  • 2
    • 79960530471 scopus 로고    scopus 로고
    • Automated extraction of radiation dose information from CT dose report images
    • 21606269 10.2214/AJR.10.5718
    • Li X, Zhang D, Liu B: Automated extraction of radiation dose information from CT dose report images. AJR Am J Roentgenol 196:W781-783, 2011
    • (2011) AJR Am J Roentgenol , vol.196 , pp. 781-783
    • Li, X.1    Zhang, D.2    Liu, B.3
  • 4
    • 84877737112 scopus 로고    scopus 로고
    • Automated PACS retrieval and processing of dose data from legacy CT systems
    • Cheng PM: Automated PACS retrieval and processing of dose data from legacy CT systems. American Roentgen Ray Society Annual Meeting, 2011
    • (2011) American Roentgen Ray Society Annual Meeting
    • Cheng, P.M.1
  • 7
    • 77953263387 scopus 로고    scopus 로고
    • Patient size measured on CT images as a function of age at a tertiary care children's hospital
    • 20489103 10.2214/AJR.09.3771
    • Kleinman PL, Strauss KJ, Zurakowski D, Buckley KS, Taylor GA: Patient size measured on CT images as a function of age at a tertiary care children's hospital. AJR Am J Roentgenol 194:1611-1619, 2010
    • (2010) AJR Am J Roentgenol , vol.194 , pp. 1611-1619
    • Kleinman, P.L.1    Strauss, K.J.2    Zurakowski, D.3    Buckley, K.S.4    Taylor, G.A.5
  • 8
    • 22544435185 scopus 로고    scopus 로고
    • Comparison of different body size parameters for individual dose adaptation in body CT of adults
    • 16040914 10.1148/radiol.2362041327
    • Menke J: Comparison of different body size parameters for individual dose adaptation in body CT of adults. Radiology 236:565-571, 2005
    • (2005) Radiology , vol.236 , pp. 565-571
    • Menke, J.1
  • 9
    • 77954718641 scopus 로고    scopus 로고
    • AP diameter shows the strongest correlation with CTDI and DLP in abdominal and chest CT
    • 20332128 10.1093/rpd/ncq115
    • Zarb F, Rainford L, McEntee MF: AP diameter shows the strongest correlation with CTDI and DLP in abdominal and chest CT. Radiat Prot Dosimetry 140:266-273, 2010
    • (2010) Radiat Prot Dosimetry , vol.140 , pp. 266-273
    • Zarb, F.1    Rainford, L.2    McEntee, M.F.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.