메뉴 건너뛰기




Volumn 37, Issue 8, 2013, Pages 89-95

A new fault diagnosis method for power transformer winding deformation based on vibration

Author keywords

Fault diagnosis; Fault location; Power transformer; Vibration method; Winding deformation

Indexed keywords

CHARACTERISTIC FREQUENCIES; FAULT DIAGNOSIS METHOD; FAULT DIAGNOSIS MODEL; FUNDAMENTAL FREQUENCIES; MODEL-BASED DIAGNOSTICS; TRANSFORMER WINDING DEFORMATIONS; VIBRATION METHOD; WINDING DEFORMATIONS;

EID: 84877645010     PISSN: 10001026     EISSN: None     Source Type: Journal    
DOI: 10.7500/AEPS201209202     Document Type: Article
Times cited : (63)

References (17)
  • 1
    • 0039171312 scopus 로고    scopus 로고
    • The application of neural network in the fault identification of transformers
    • LI Yongli, GU Fuhai, LIU Zhihua. The application of neural network in the fault identification of transformers [J]. Automation of Electric Power Systems, 1999, 23(4): 22-23.
    • (1999) Automation of Electric Power Systems , vol.23 , Issue.4 , pp. 22-23
    • Li, Y.1    Gu, F.2    Liu, Z.3
  • 2
    • 77953253581 scopus 로고    scopus 로고
    • A fault diagnosis method for power transformer based on multiclass multiple-kernel learning support vector machine
    • GUO Chuangxin, ZHU Chengzhi, ZHANG Lin, et al. A fault diagnosis method for power transformer based on multiclass multiple-kernel learning support vector machine [J]. Proceedings of the CSEE, 2010, 30(13): 128-134.
    • (2010) Proceedings of the CSEE , vol.30 , Issue.13 , pp. 128-134
    • Guo, C.1    Zhu, C.2    Zhang, L.3
  • 3
    • 34249302566 scopus 로고    scopus 로고
    • Statistics and analysis on power transformer damages caused by short-circuit fault in 110 kV and higher voltage classes
    • JIN Wenlong, CHEN Jianhua, LI Guangfan, et al. Statistics and analysis on power transformer damages caused by short-circuit fault in 110 kV and higher voltage classes [J]. Power System Technology, 1999, 23(6): 70-74.
    • (1999) Power System Technology , vol.23 , Issue.6 , pp. 70-74
    • Jin, W.1    Chen, J.2    Li, G.3
  • 4
    • 77952832574 scopus 로고    scopus 로고
    • The comparison study on LVI and FRA method of detecting winding deformation faults in transformers
    • WANG Yu, LI Yanming, ZHANG Chengliang. The comparison study on LVI and FRA method of detecting winding deformation faults in transformers [J]. High Voltage Engineering, 1997, 23(1): 13-15.
    • (1997) High Voltage Engineering , vol.23 , Issue.1 , pp. 13-15
    • Wang, Y.1    Li, Y.2    Zhang, C.3
  • 5
    • 11244289267 scopus 로고    scopus 로고
    • Diagnosis of winding deformation of transformer by impedance method and FRA
    • HUANG Hua, ZHOU Jianguo, JIANG Yimin, et al. Diagnosis of winding deformation of transformer by impedance method and FRA [J]. High Voltage Engineering, 1999, 25(2): 70-73.
    • (1999) High Voltage Engineering , vol.25 , Issue.2 , pp. 70-73
    • Huang, H.1    Zhou, J.2    Jiang, Y.3
  • 6
    • 33244487765 scopus 로고    scopus 로고
    • Transformer tank vibration modeling as a method of detecting winding deformations: Part I theoretical foundation
    • GARCIA B, BURGOS J C, ALONSO A M. Transformer tank vibration modeling as a method of detecting winding deformations: Part I theoretical foundation [J]. IEEE Trans on Power Delivery, 2006, 21(1): 157-163.
    • (2006) IEEE Trans on Power Delivery , vol.21 , Issue.1 , pp. 157-163
    • Garcia, B.1    Burgos, J.C.2    Alonso, A.M.3
  • 7
    • 33244486499 scopus 로고    scopus 로고
    • Transformer tank vibration modeling as a method of detecting winding deformations: Part II experimental verification
    • GARCIA B, BURGOS J C, ALONSO A M. Transformer tank vibration modeling as a method of detecting winding deformations: Part II experimental verification [J]. IEEE Trans on Power Delivery, 2006, 21(1): 164-169.
    • (2006) IEEE Trans on Power Delivery , vol.21 , Issue.1 , pp. 164-169
    • Garcia, B.1    Burgos, J.C.2    Alonso, A.M.3
  • 8
    • 34047207947 scopus 로고    scopus 로고
    • The application of vibration method in monitoring the condition of transformer windings
    • JI Shengchang, WANG Shishan, LI Qingquan, et al. The application of vibration method in monitoring the condition of transformer windings [J]. High Voltage Engineering, 2002, 28(4): 12-15.
    • (2002) High Voltage Engineering , vol.28 , Issue.4 , pp. 12-15
    • Ji, S.1    Wang, S.2    Li, Q.3
  • 9
    • 33947513233 scopus 로고    scopus 로고
    • Features of vibration signal of power transformer using the wavelet theory
    • YAN Qiurong, LIU Xin, YIN Jianguo. Features of vibration signal of power transformer using the wavelet theory. High Voltage Engineering, 2007, 33(1): 165-168.
    • (2007) High Voltage Engineering , vol.33 , Issue.1 , pp. 165-168
    • Yan, Q.1    Liu, X.2    Yin, J.3
  • 10
    • 0141566882 scopus 로고    scopus 로고
    • Application of on-load current method in monitoring the condition of transformers core based on the vibration analysis method
    • JI Shengchang, LI Yanming, FU Chenzhao. Application of on-load current method in monitoring the condition of transformers core based on the vibration analysis method [J]. Proceedings of the CSEE, 2003, 23(6): 154-158.
    • (2003) Proceedings of the CSEE , vol.23 , Issue.6 , pp. 154-158
    • Ji, S.1    Li, Y.2    Fu, C.3
  • 11
    • 0036658370 scopus 로고    scopus 로고
    • Stability of axial vibration of power transformer windings
    • WANG Zhangqi, WANG Meng. Stability of axial vibration of power transformer windings [J]. Proceedings of the CSEE, 2002, 22(7): 24-28.
    • (2002) Proceedings of the CSEE , vol.22 , Issue.7 , pp. 24-28
    • Wang, Z.1    Wang, M.2
  • 12
    • 0008632418 scopus 로고    scopus 로고
    • The vibration measuring system for monitoring core and winding condition of power transformer
    • JI Shengchang, LIU Weiguo, SHAN Ping, et al. The vibration measuring system for monitoring core and winding condition of power transformer [J]. High Voltage Engineering, 2000, 26(6): 1-3.
    • (2000) High Voltage Engineering , vol.26 , Issue.6 , pp. 1-3
    • Ji, S.1    Liu, W.2    Shan, P.3
  • 13
    • 84863018844 scopus 로고    scopus 로고
    • Fault location for distribution network based on correlation analysis matching degree
    • LI Xun, GONG Qingwu, XIAO Hui, et al. Fault location for distribution network based on correlation analysis matching degree [J]. Automation of Electric Power Systems, 2012, 36(1): 90-95.
    • (2012) Automation of Electric Power Systems , vol.36 , Issue.1 , pp. 90-95
    • Li, X.1    Gong, Q.2    Xiao, H.3
  • 14
    • 65749113546 scopus 로고    scopus 로고
    • Research on time delay estimation algorithm based on generalized cross correlation in acoustic emission source location
    • DENG Aidong, BAO Yongqiang, ZHAO Li. Research on time delay estimation algorithm based on generalized cross correlation in acoustic emission source location [J]. Proceedings of the CSEE, 2009, 29(14): 86-92.
    • (2009) Proceedings of the CSEE , vol.29 , Issue.14 , pp. 86-92
    • Deng, A.1    Bao, Y.2    Zhao, L.3
  • 15
  • 16
    • 84877658308 scopus 로고    scopus 로고
    • Chinese source
    • 2009.
    • (2009)
  • 17
    • 70749115845 scopus 로고    scopus 로고
    • Large power transformer fault diagnosis based on a diagnosis model combined with several methods
    • YANG Tingfang, LI Jinglu, ZENG Xiangjun, et al. Large power transformer fault diagnosis based on a diagnosis model combined with several methods [J]. Automation of Electric Power Systems, 2009, 33(20): 92-95.
    • (2009) Automation of Electric Power Systems , vol.33 , Issue.20 , pp. 92-95
    • Yang, T.1    Li, J.2    Zeng, X.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.