-
1
-
-
0001393431
-
Flexor tendon grafts in the fingers and thumb: an evaluation of end results
-
Boyes J.H. Flexor tendon grafts in the fingers and thumb: an evaluation of end results. J Bone Joint Surg Am 1950, 32:489-499.
-
(1950)
J Bone Joint Surg Am
, vol.32
, pp. 489-499
-
-
Boyes, J.H.1
-
2
-
-
0015136630
-
Flexor tendon grafts in the fingers and thumb: a study of factors influencing results in 1000 cases
-
Boyes J.H., Stark H.H. Flexor tendon grafts in the fingers and thumb: a study of factors influencing results in 1000 cases. J Bone Joint Surg Am 1971, 53:1332-1342.
-
(1971)
J Bone Joint Surg Am
, vol.53
, pp. 1332-1342
-
-
Boyes, J.H.1
Stark, H.H.2
-
4
-
-
0015098717
-
Flexor tendon reconstruction in severely damaged hands: a two-stage procedure using a silicone-Dacron reinforced gliding prosthesis prior to tendon grafting
-
Hunter J.M., Salisbury R.E. Flexor tendon reconstruction in severely damaged hands: a two-stage procedure using a silicone-Dacron reinforced gliding prosthesis prior to tendon grafting. J Bone Joint Surg Am 1971, 53:829-858.
-
(1971)
J Bone Joint Surg Am
, vol.53
, pp. 829-858
-
-
Hunter, J.M.1
Salisbury, R.E.2
-
5
-
-
0028263033
-
Tendon graft anatomy and harvesting
-
Wehbé M.A. Tendon graft anatomy and harvesting. Orthop Rev 1994, 23:253-256.
-
(1994)
Orthop Rev
, vol.23
, pp. 253-256
-
-
Wehbé, M.A.1
-
6
-
-
0027500388
-
Morphologic and biomechanical comparison of tendons used as free grafts
-
Carlson G.D., Botte M.J., Josephs M.S., et al. Morphologic and biomechanical comparison of tendons used as free grafts. J Hand Surg Am 1993, 18:76-82.
-
(1993)
J Hand Surg Am
, vol.18
, pp. 76-82
-
-
Carlson, G.D.1
Botte, M.J.2
Josephs, M.S.3
-
7
-
-
0023679828
-
Staged flexor tendon reconstruction in the fingers and hand
-
Amadio P.C., Wood M.B., Cooney W.P., et al. Staged flexor tendon reconstruction in the fingers and hand. J Hand Surg Am 1988, 13:559-562.
-
(1988)
J Hand Surg Am
, vol.13
, pp. 559-562
-
-
Amadio, P.C.1
Wood, M.B.2
Cooney, W.P.3
-
8
-
-
0016596441
-
Les greffes de tendons flechisseurs après implantation provisoire d'une tige en silicone. Etude et resultats de 32 cas
-
[in French]
-
Chamay A., Verdan C., Simonetta C. Les greffes de tendons flechisseurs après implantation provisoire d'une tige en silicone. Etude et resultats de 32 cas. Rev Chir Orthop Reparatrice Appar Mot 1975, 61:599-610. [in French].
-
(1975)
Rev Chir Orthop Reparatrice Appar Mot
, vol.61
, pp. 599-610
-
-
Chamay, A.1
Verdan, C.2
Simonetta, C.3
-
9
-
-
0017610028
-
A review of 100 flexor tendon reconstructions with prosthesis
-
Honner R., Meares A. A review of 100 flexor tendon reconstructions with prosthesis. Hand 1977, 9:226-231.
-
(1977)
Hand
, vol.9
, pp. 226-231
-
-
Honner, R.1
Meares, A.2
-
10
-
-
0021064441
-
Staged flexor tendon reconstruction
-
Hunter J.M. Staged flexor tendon reconstruction. J Hand Surg Am 1983, 8:789-793.
-
(1983)
J Hand Surg Am
, vol.8
, pp. 789-793
-
-
Hunter, J.M.1
-
11
-
-
0033730546
-
Two-stage flexor tendon grafting in children
-
Valenti P., Gilbert A. Two-stage flexor tendon grafting in children. Hand Clin 2000, 16:573-578.
-
(2000)
Hand Clin
, vol.16
, pp. 573-578
-
-
Valenti, P.1
Gilbert, A.2
-
12
-
-
0022527667
-
Two-stage flexor-tendon reconstruction: ten-year experience
-
Wehbe M.A., Hunter J.M., Schneider L.H., et al. Two-stage flexor-tendon reconstruction: ten-year experience. J Bone Joint Surg Am 1986, 68:752-763.
-
(1986)
J Bone Joint Surg Am
, vol.68
, pp. 752-763
-
-
Wehbe, M.A.1
Hunter, J.M.2
Schneider, L.H.3
-
13
-
-
77953903066
-
Two-stage plasty in flexor tendon injuries of fingers within the digital synovial sheath
-
Paneva-Holevich E. Two-stage plasty in flexor tendon injuries of fingers within the digital synovial sheath. Acta Chir Plast 1965, 7:112-124.
-
(1965)
Acta Chir Plast
, vol.7
, pp. 112-124
-
-
Paneva-Holevich, E.1
-
14
-
-
0015290584
-
Combined two-stage tenoplasty with silicone rods for multiple flexor tendon injuries in "no-man's land."
-
Chong J.K., Cramer L.M., Culf N.K. Combined two-stage tenoplasty with silicone rods for multiple flexor tendon injuries in "no-man's land." J Trauma 1972, 12:104-121.
-
(1972)
J Trauma
, vol.12
, pp. 104-121
-
-
Chong, J.K.1
Cramer, L.M.2
Culf, N.K.3
-
15
-
-
0015320786
-
Use of a pedicled tendon transfer with a silicone rod in complicated secondary flexor tendon repairs
-
Kessler F.B. Use of a pedicled tendon transfer with a silicone rod in complicated secondary flexor tendon repairs. Plast Reconstr Surg 1972, 49:439-443.
-
(1972)
Plast Reconstr Surg
, vol.49
, pp. 439-443
-
-
Kessler, F.B.1
-
16
-
-
0017181706
-
Experimental flexor tendon healing without adhesion formation: a new concept of tendon nutrition and intrinsic healing mechanisms. A preliminary report
-
Lundborg G. Experimental flexor tendon healing without adhesion formation: a new concept of tendon nutrition and intrinsic healing mechanisms. A preliminary report. Hand 1976, 8:235-238.
-
(1976)
Hand
, vol.8
, pp. 235-238
-
-
Lundborg, G.1
-
17
-
-
0028197331
-
Variations in cellular proliferation and matrix synthesis in intrasynovial and extrasynovial tendons: an in vitro study in dogs
-
Abrahamsson S.O., Gelberman R.H., Lohmander S.L. Variations in cellular proliferation and matrix synthesis in intrasynovial and extrasynovial tendons: an in vitro study in dogs. J Hand Surg Am 1994, 19:259-265.
-
(1994)
J Hand Surg Am
, vol.19
, pp. 259-265
-
-
Abrahamsson, S.O.1
Gelberman, R.H.2
Lohmander, S.L.3
-
18
-
-
0027087402
-
Intercalary flexor tendon grafts: a morphological study of intrasynovial and extrasynovial donor tendons
-
Gelberman R.H., Seiler J.G., Rosenberg A.E., et al. Intercalary flexor tendon grafts: a morphological study of intrasynovial and extrasynovial donor tendons. Scand J Plast Reconstr Surg Hand Surg 1992, 26:257-264.
-
(1992)
Scand J Plast Reconstr Surg Hand Surg
, vol.26
, pp. 257-264
-
-
Gelberman, R.H.1
Seiler, J.G.2
Rosenberg, A.E.3
-
19
-
-
0027301352
-
Autogenous flexor tendon grafts: a biomechanical and morphological study in dogs
-
Seiler J.G., Gelberman R.H., Williams C.S., et al. Autogenous flexor tendon grafts: a biomechanical and morphological study in dogs. J Bone Joint Surg Am 1993, 75:1004-1014.
-
(1993)
J Bone Joint Surg Am
, vol.75
, pp. 1004-1014
-
-
Seiler, J.G.1
Gelberman, R.H.2
Williams, C.S.3
-
20
-
-
0031452347
-
Autogenous flexor tendon grafts. Biologic mechanisms for incorporation
-
Seiler J.G., Chu C.R., Amiel D., et al. Autogenous flexor tendon grafts. Biologic mechanisms for incorporation. Clin Orthop Relat Res 1997, 345:239-247.
-
(1997)
Clin Orthop Relat Res
, vol.345
, pp. 239-247
-
-
Seiler, J.G.1
Chu, C.R.2
Amiel, D.3
-
21
-
-
0042171675
-
Two-stage flexor tendon reconstruction in zone II using a silicone rod and a pedicled intrasynovial graft
-
Beris A.E., Darlis N.A., Korompilias A.V., et al. Two-stage flexor tendon reconstruction in zone II using a silicone rod and a pedicled intrasynovial graft. J Hand Surg Am 2003, 28:652-660.
-
(2003)
J Hand Surg Am
, vol.28
, pp. 652-660
-
-
Beris, A.E.1
Darlis, N.A.2
Korompilias, A.V.3
-
22
-
-
0014444380
-
Two-stage tenoplasty in injury of the flexor tendons of the hand
-
Paneva-Holevich E. Two-stage tenoplasty in injury of the flexor tendons of the hand. J Bone Joint Surg Am 1969, 51:21-32.
-
(1969)
J Bone Joint Surg Am
, vol.51
, pp. 21-32
-
-
Paneva-Holevich, E.1
-
23
-
-
0014189977
-
The zig-zag volar-digital incision for flexor tendon surgery
-
Bruner J.M. The zig-zag volar-digital incision for flexor tendon surgery. Plast Reconstr Surg 1967, 40:571-574.
-
(1967)
Plast Reconstr Surg
, vol.40
, pp. 571-574
-
-
Bruner, J.M.1
-
24
-
-
18844426282
-
Flexor tendon reconstruction: current concepts and techniques
-
Goldfarb C.A., Gelberman R.H., Boyer M.I. Flexor tendon reconstruction: current concepts and techniques. J Hand Surg Am 2005, 5:123-130.
-
(2005)
J Hand Surg Am
, vol.5
, pp. 123-130
-
-
Goldfarb, C.A.1
Gelberman, R.H.2
Boyer, M.I.3
-
25
-
-
0020372436
-
Staged flexor tendon reconstruction using the method of Hunter
-
Schneider L.H. Staged flexor tendon reconstruction using the method of Hunter. Clin Orthop Relat Res 1982, 171:164-171.
-
(1982)
Clin Orthop Relat Res
, vol.171
, pp. 164-171
-
-
Schneider, L.H.1
-
26
-
-
0017084558
-
Evaluation of the two-stage flexor-tendon reconstruction in severely damaged digits
-
Weinstein S.L., Sprague B.L., Flatt A.E. Evaluation of the two-stage flexor-tendon reconstruction in severely damaged digits. J Bone Joint Surg Am 1976, 58:786-791.
-
(1976)
J Bone Joint Surg Am
, vol.58
, pp. 786-791
-
-
Weinstein, S.L.1
Sprague, B.L.2
Flatt, A.E.3
-
27
-
-
0029881065
-
Longstanding flexor tendon lesions treated by two-stage tendon graft
-
Alnot J.Y., Mouton P., Bisson P. Longstanding flexor tendon lesions treated by two-stage tendon graft. Ann Chir Main 1996, 15:25-35.
-
(1996)
Ann Chir Main
, vol.15
, pp. 25-35
-
-
Alnot, J.Y.1
Mouton, P.2
Bisson, P.3
-
29
-
-
0024425225
-
A mechanical study of six pulley reconstruction techniques: part I Mechanical effectiveness
-
Widstrom C., Johnson G., Doyle J., et al. A mechanical study of six pulley reconstruction techniques: part I Mechanical effectiveness. J Hand Surg Am 1989, 14:821-825.
-
(1989)
J Hand Surg Am
, vol.14
, pp. 821-825
-
-
Widstrom, C.1
Johnson, G.2
Doyle, J.3
-
30
-
-
0017968181
-
Digital pulley reconstruction employing the always present rim of the previous pulley
-
Kleinert H.E., Bennett J.B. Digital pulley reconstruction employing the always present rim of the previous pulley. J Hand Surg Am 1978, 3:297-298.
-
(1978)
J Hand Surg Am
, vol.3
, pp. 297-298
-
-
Kleinert, H.E.1
Bennett, J.B.2
-
31
-
-
0023406834
-
Three-loop technique for A2 pulley reconstruction
-
Okutsu I., Ninomiya S., Hiraki S., et al. Three-loop technique for A2 pulley reconstruction. J Hand Surg Am 1987, 12:790-794.
-
(1987)
J Hand Surg Am
, vol.12
, pp. 790-794
-
-
Okutsu, I.1
Ninomiya, S.2
Hiraki, S.3
-
32
-
-
0030890597
-
Staged flexor tendon reconstruction using pedicled tendon graft from the flexor digitorum superficialis
-
Naam N.H. Staged flexor tendon reconstruction using pedicled tendon graft from the flexor digitorum superficialis. J Hand Surg Am 1997, 22:323-327.
-
(1997)
J Hand Surg Am
, vol.22
, pp. 323-327
-
-
Naam, N.H.1
-
33
-
-
0030665901
-
Two-stage treatment of flexor tendon ruptures. Silicone rod complications analyzed in 109 digits
-
Soucacos P.N., Beris A.E., Malizos K.N., et al. Two-stage treatment of flexor tendon ruptures. Silicone rod complications analyzed in 109 digits. Acta Orthop Scand 1997, 68:48-51.
-
(1997)
Acta Orthop Scand
, vol.68
, pp. 48-51
-
-
Soucacos, P.N.1
Beris, A.E.2
Malizos, K.N.3
-
34
-
-
0024350585
-
Flexor tendon surgery. Part 2: free tendon grafts and tenolysis
-
Strickland J. Flexor tendon surgery. Part 2: free tendon grafts and tenolysis. J Hand Surg Br 1989, 14:368-382.
-
(1989)
J Hand Surg Br
, vol.14
, pp. 368-382
-
-
Strickland, J.1
-
35
-
-
0022189694
-
Flexor tenolysis
-
Strickland J. Flexor tenolysis. Hand Clin 1985, 1:121-132.
-
(1985)
Hand Clin
, vol.1
, pp. 121-132
-
-
Strickland, J.1
-
36
-
-
0020827044
-
Report of the committee on tendon injuries
-
Kleinert H.E., Verdan C. Report of the committee on tendon injuries. J Hand Surg Am 1983, 5:794-798.
-
(1983)
J Hand Surg Am
, vol.5
, pp. 794-798
-
-
Kleinert, H.E.1
Verdan, C.2
-
37
-
-
0018855157
-
Two-stage superficialis tendon reconstruction in severely damaged fingers
-
Chuinard R.G., Dabezies E.J., Mathews R.E. Two-stage superficialis tendon reconstruction in severely damaged fingers. J Hand Surg Am 1980, 5:135-143.
-
(1980)
J Hand Surg Am
, vol.5
, pp. 135-143
-
-
Chuinard, R.G.1
Dabezies, E.J.2
Mathews, R.E.3
-
38
-
-
0036798425
-
Functional absence of flexor digitorum superficialis to the little finger and absence of palmaris longus-is there a link?
-
Thompson N.W., Mockford B.J., Rasheed T., et al. Functional absence of flexor digitorum superficialis to the little finger and absence of palmaris longus-is there a link?. J Hand Surg Br 2002, 27:433-434.
-
(2002)
J Hand Surg Br
, vol.27
, pp. 433-434
-
-
Thompson, N.W.1
Mockford, B.J.2
Rasheed, T.3
-
39
-
-
0018253022
-
Flexor tendon grafting. The use of a modified Hunter's technique
-
[in French]
-
Foucher G., Merle M., Sibilly A., et al. Flexor tendon grafting. The use of a modified Hunter's technique. Rev Chir Orthop Reparatrice Appar Mot 1978, 64:703-705. [in French].
-
(1978)
Rev Chir Orthop Reparatrice Appar Mot
, vol.64
, pp. 703-705
-
-
Foucher, G.1
Merle, M.2
Sibilly, A.3
-
40
-
-
0036066602
-
Staged flexor tendon reconstruction fingertip to palm
-
Coyle M.P., Leddy T.P., Leddy J.P. Staged flexor tendon reconstruction fingertip to palm. J Hand Surg Am 2002, 27:581-585.
-
(2002)
J Hand Surg Am
, vol.27
, pp. 581-585
-
-
Coyle, M.P.1
Leddy, T.P.2
Leddy, J.P.3
-
41
-
-
0023694164
-
Post operative management of flexor tendon grafting
-
Tonkin M., Hagberg L., Lister G. Post operative management of flexor tendon grafting. J Hand Surg Br 1988, 13:277-281.
-
(1988)
J Hand Surg Br
, vol.13
, pp. 277-281
-
-
Tonkin, M.1
Hagberg, L.2
Lister, G.3
-
42
-
-
0020578389
-
An evaluation of the two-stage flexor tendon reconstruction technique
-
LaSalle W.B., Strickland J.W. An evaluation of the two-stage flexor tendon reconstruction technique. J Hand Surg Am 1983, 8:263-267.
-
(1983)
J Hand Surg Am
, vol.8
, pp. 263-267
-
-
LaSalle, W.B.1
Strickland, J.W.2
-
43
-
-
0017821936
-
Staged reconstruction of flexor tendons with a silicone rod and a "pedicled" sublimis transfer
-
Winspur I., Dennis P.B., Boswick J.A. Staged reconstruction of flexor tendons with a silicone rod and a "pedicled" sublimis transfer. Plast Reconstr Surg 1978, 61:756-761.
-
(1978)
Plast Reconstr Surg
, vol.61
, pp. 756-761
-
-
Winspur, I.1
Dennis, P.B.2
Boswick, J.A.3
-
44
-
-
0018645290
-
Experience with a two-stage pedicled flexor tendon graft
-
Brug E., Stedtfeld H.W. Experience with a two-stage pedicled flexor tendon graft. Hand 1979, 11:198-205.
-
(1979)
Hand
, vol.11
, pp. 198-205
-
-
Brug, E.1
Stedtfeld, H.W.2
-
45
-
-
0020374901
-
Two-stage reconstruction of the flexor tendons
-
Paneva-Holevich E. Two-stage reconstruction of the flexor tendons. Int Orthop 1982, 6:133-138.
-
(1982)
Int Orthop
, vol.6
, pp. 133-138
-
-
Paneva-Holevich, E.1
-
46
-
-
0031595175
-
Secondary reconstruction of flexor tendon function in the fingers
-
Brug E., Wetterkamp D., Neuber M., et al. Secondary reconstruction of flexor tendon function in the fingers. Unfallchirurg 1998, 101:415-425.
-
(1998)
Unfallchirurg
, vol.101
, pp. 415-425
-
-
Brug, E.1
Wetterkamp, D.2
Neuber, M.3
|