Volumn 2, Issue 4, 2012, Pages 42-51

Importance of attenuation correction (AC) for small animal pet imaging

Author keywords

Attenuation correction; MicroPET; Molecular imaging; PET imaging; Small animal

Indexed keywords

ACCURACY; ANIMAL EXPERIMENT; ANIMAL MODEL; ANIMAL TISSUE; ARTICLE; ATTENUATION CORRECTION; BLADDER MUCOSA; BREAST CANCER; COMPUTER ASSISTED TOMOGRAPHY; CONSTANTS AND COEFFICIENTS; DATA ANALYSIS; FEMALE; HUMAN; HUMAN CELL; IMAGE ANALYSIS; IMAGE RECONSTRUCTION; INTERMETHOD COMPARISON; KIDNEY PARENCHYMA; MOUSE; NONHUMAN; POSITRON EMISSION TOMOGRAPHY; STATISTICAL ANALYSIS; TUMOR VOLUME;

EID: 84877309477     PISSN: None     EISSN: 20754418     Source Type: Journal    
DOI: 10.3390/diagnostics2040042     Document Type: Article
Times cited : (22)

References (18)
  • 1
    • 0036984004 scopus 로고    scopus 로고
    • Molecular imaging: The application of small animal positron emission tomography
    • Rowland, D.J.; Lewis, J.S.; Welch, M.J. Molecular imaging: The application of small animal positron emission tomography. J. Cell. Biochem. Suppl. 2002, 39, 110-115.
    • (2002) J. Cell. Biochem. Suppl. , vol.39 , pp. 110-115
    • Rowland, D.J.1    Lewis, J.S.2    Welch, M.J.3
  • 2
    • 22844452107 scopus 로고    scopus 로고
    • Attenuation correction for small animal PET tomographs
    • Chow, P.L.; Rannou, F.R.; Chatziioannou, A.F. Attenuation correction for small animal PET tomographs. Phys. Med. Biol. 2005, 50, 1837-1850.
    • (2005) Phys. Med. Biol. , vol.50 , pp. 1837-1850
    • Chow, P.L.1    Rannou, F.R.2    Chatziioannou, A.F.3
  • 3
    • 1642471697 scopus 로고    scopus 로고
    • Attenuation compensation in cerebral 3D PET: Effect of the attenuation map on absolute and relative quantitation
    • Zaidi, H.; Montandon, M.L.; Slosman, D.O. Attenuation compensation in cerebral 3D PET: Effect of the attenuation map on absolute and relative quantitation. Eur. J. Nucl. Med. Mol. Imaging 2004, 31, 52-63.
    • (2004) Eur. J. Nucl. Med. Mol. Imaging , vol.31 , pp. 52-63
    • Zaidi, H.1    Montandon, M.L.2    Slosman, D.O.3
  • 4
    • 0036093165 scopus 로고    scopus 로고
    • PET attenuation coefficients from CT images: Experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients
    • Burger, C.; Goerres, G.; Schoenes, S.; Buck, A.; Lonn, A.; von Schulthess, G. PET attenuation coefficients from CT images: Experimental evaluation of the transformation of CT into PET 511-keV attenuation coefficients. Eur. J. Nucl. Med. Mol. Imaging 2002, 29, 922-927.
    • (2002) Eur. J. Nucl. Med. Mol. Imaging , vol.29 , pp. 922-927
    • Burger, C.1    Goerres, G.2    Schoenes, S.3    Buck, A.4    Lonn, A.5    von Schulthess, G.6
  • 5
    • 0033778825 scopus 로고    scopus 로고
    • Attenuation correction in hybrid positron emission tomography
    • Turkington, T.G. Attenuation correction in hybrid positron emission tomography. Semin. Nucl. Med. 2000, 30, 255-267.
    • (2000) Semin. Nucl. Med. , vol.30 , pp. 255-267
    • Turkington, T.G.1
  • 8
    • 0023640412 scopus 로고
    • Treatment of axial data in three-dimensional PET
    • Daube-Witherspoon, M.E.; Muehllehner, G. Treatment of axial data in three-dimensional PET. J. Nucl. Med. 1987, 28, 1717-1724.
    • (1987) J. Nucl. Med. , vol.28 , pp. 1717-1724
    • Daube-Witherspoon, M.E.1    Muehllehner, G.2
  • 9
    • 0034178287 scopus 로고    scopus 로고
    • Resolution and noise properties of MAP reconstruction for fully 3-D PET
    • Qi, J.; Leahy, R.M. Resolution and noise properties of MAP reconstruction for fully 3-D PET. IEEE Trans. Med. Imaging 2000, 19, 493-506.
    • (2000) IEEE Trans. Med. Imaging , vol.19 , pp. 493-506
    • Qi, J.1    Leahy, R.M.2
  • 10
    • 70149107292 scopus 로고    scopus 로고
    • Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurements
    • Tohme, M.S.; Qi, J. Iterative image reconstruction for positron emission tomography based on a detector response function estimated from point source measurements. Phys. Med. Biol. 2009, 54, 3709-3725.
    • (2009) Phys. Med. Biol. , vol.54 , pp. 3709-3725
    • Tohme, M.S.1    Qi, J.2
  • 11
    • 34147126296 scopus 로고    scopus 로고
    • A scatter-corrected list-mode reconstruction and a practical scatter/random approximation technique for dynamic PET imaging
    • Cheng, J.C.; Rahmim, A.; Blinder, S.; Camborde, M.L.; Raywood, K.; Sossi, V. A scatter-corrected list-mode reconstruction and a practical scatter/random approximation technique for dynamic PET imaging. Phys. Med. Biol. 2007, 52, 2089-2106.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 2089-2106
    • Cheng, J.C.1    Rahmim, A.2    Blinder, S.3    Camborde, M.L.4    Raywood, K.5    Sossi, V.6
  • 12
    • 33748163247 scopus 로고    scopus 로고
    • Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET
    • Ay, M.R.; Zaidi, H. Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET. Eur. J. Nucl. Med. Mol. Imaging. 2006, 33, 1301-1313.
    • (2006) Eur. J. Nucl. Med. Mol. Imaging. , vol.33 , pp. 1301-1313
    • Ay, M.R.1    Zaidi, H.2
  • 13
    • 0034081130 scopus 로고    scopus 로고
    • Evaluation of a scatter correction technique for single photon transmission measurements in PET by means of Monte Carlo simulations
    • Wegmann, K.; Brix, G. Evaluation of a scatter correction technique for single photon transmission measurements in PET by means of Monte Carlo simulations. Nuklearmedizin 2000, 39, 67-71.
    • (2000) Nuklearmedizin , vol.39 , pp. 67-71
    • Wegmann, K.1    Brix, G.2
  • 14
    • 0034753439 scopus 로고    scopus 로고
    • Scatter modelling and correction strategies in fully 3-D PET
    • Zaidi, H. Scatter modelling and correction strategies in fully 3-D PET. Nucl. Med. Commun. 2001, 22, 1181-1184.
    • (2001) Nucl. Med. Commun. , vol.22 , pp. 1181-1184
    • Zaidi, H.1
  • 15
    • 0029001016 scopus 로고
    • Singles transmission in volume-imaging PET with a 137Cs source
    • Karp, J.S.; Muehllehner, G.; Qu, H.; Yan, X.H. Singles transmission in volume-imaging PET with a 137Cs source. Phys. Med. Biol. 1995, 40, 929-944.
    • (1995) Phys. Med. Biol. , vol.40 , pp. 929-944
    • Karp, J.S.1    Muehllehner, G.2    Qu, H.3    Yan, X.H.4
  • 16
  • 17
    • 0031791001 scopus 로고    scopus 로고
    • Attenuation correction for a combined 3D PET/CT scanner
    • Kinahan, P.E.; Townsend, D.W.; Beyer, T.; Sashin, D. Attenuation correction for a combined 3D PET/CT scanner. Med. Phys. 1998, 25, 2046-2053.
    • (1998) Med. Phys. , vol.25 , pp. 2046-2053
    • Kinahan, P.E.1    Townsend, D.W.2    Beyer, T.3    Sashin, D.4
  • 18
    • 56749178486 scopus 로고    scopus 로고
    • Current trends in preclinical PET system design
    • Levin, C.S.; Zaidi, H. Current trends in preclinical PET system design. PET Clin. 2007, 2, 125-160.
    • (2007) PET Clin , vol.2 , pp. 125-160
    • Levin, C.S.1    Zaidi, H.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.