-
1
-
-
84877124251
-
-
PricewaterhouseCoopers' Health Research Institute PricewaterhouseCoopers LLP, Delaware
-
PricewaterhouseCoopers' Health Research Institute (2010) HealthCast: The customization of diagnosis, care and cure. PricewaterhouseCoopers LLP, Delaware, pp 1-56
-
(2010)
HealthCast: The Customization of Diagnosis, Care and Cure
, pp. 1-56
-
-
-
2
-
-
0007241938
-
-
KGMM Alberti L. Krall (eds) 5 Elsevier Amsterdam
-
Cardosi MF, Turner APF (1990) In: Alberti KGMM, Krall LP (eds) The diabetes annual, vol 5. Elsevier, Amsterdam, pp 254-272
-
(1990)
The Diabetes Annual
, pp. 254-272
-
-
Cardosi, M.F.1
Turner, A.P.F.2
-
4
-
-
0034680498
-
Biosensors-sense and sensitivity
-
10.1126/science.290.5495.1315 1:CAS:528:DC%2BD3cXotlWgsbw%3D
-
Turner APF (2000) Biosensors-sense and sensitivity. Science 290(5495):1315-1317
-
(2000)
Science
, vol.290
, Issue.5495
, pp. 1315-1317
-
-
Turner, A.P.F.1
-
5
-
-
53449095790
-
Over-the-counter biosensors: Past, present, and future
-
10.3390/s8095535 1:CAS:528:DC%2BD1cXhsVektrvJ
-
Lee TM-H (2008) Over-the-counter biosensors: past, present, and future. Sensors 8(9):5535-5559
-
(2008)
Sensors
, vol.8
, Issue.9
, pp. 5535-5559
-
-
Lee, T.-H.1
-
7
-
-
84877131566
-
Electrochemical polymerization for preparation of electrochemical sensors
-
1:CAS:528:DC%2BD1cXms1eisbc%3D
-
Weetall HH (2007) Electrochemical polymerization for preparation of electrochemical sensors. Handb Biosens Biochips 1:251-257
-
(2007)
Handb Biosens Biochips
, vol.1
, pp. 251-257
-
-
Weetall, H.H.1
-
8
-
-
77954449334
-
Salivary sensors in point-of-care testing
-
1:CAS:528:DC%2BC3cXpt1OktL4%3D
-
Yamaguchi M (2010) Salivary sensors in point-of-care testing. Sens Mater 22(4):143-153
-
(2010)
Sens Mater
, vol.22
, Issue.4
, pp. 143-153
-
-
Yamaguchi, M.1
-
9
-
-
79951726135
-
A contact lens with embedded sensor for monitoring tear glucose level
-
10.1016/j.bios.2010.12.042 1:CAS:528:DC%2BC3MXit1ynsb8%3D
-
Yao HF, Shum AJ, Cowan M, Lahdesmaki I, Parviz BA (2011) A contact lens with embedded sensor for monitoring tear glucose level. Biosens Bioelectron 26(7):3290-3296
-
(2011)
Biosens Bioelectron
, vol.26
, Issue.7
, pp. 3290-3296
-
-
Yao, H.F.1
Shum, A.J.2
Cowan, M.3
Lahdesmaki, I.4
Parviz, B.A.5
-
10
-
-
84987480069
-
A flexible biosensor for glucose
-
10.1002/elan.1140070110 1:CAS:528:DyaK2MXlt1Sjsbs%3D
-
Mitsubayashi K, Dicks JM, Yokoyama K, Takeuchi T, Tamiya E, Karube I (1995) A flexible biosensor for glucose. Electroanalysis 7(1):83-87
-
(1995)
Electroanalysis
, vol.7
, Issue.1
, pp. 83-87
-
-
Mitsubayashi, K.1
Dicks, J.M.2
Yokoyama, K.3
Takeuchi, T.4
Tamiya, E.5
Karube, I.6
-
11
-
-
0042205347
-
Antioxidants in tears and plasma: Inter-relationships and effect of vitamin C supplementation
-
10.1076/ceyr.27.2.55.15458
-
Choy CKM, Benzie IFF, Cho P (2003) Antioxidants in tears and plasma: Inter-relationships and effect of vitamin C supplementation. Curr Eye Res 27(1):55-60
-
(2003)
Curr Eye Res
, vol.27
, Issue.1
, pp. 55-60
-
-
Choy, C.K.M.1
Benzie, I.F.F.2
Cho, P.3
-
12
-
-
0017367259
-
Collection method-dependent concentrations of some metabolites in human tear fluid, with special reference to glucose in hyperglycemic conditions
-
Van Haeringen NJ, Glasius E (1977) Collection method-dependent concentrations of some metabolites in human tear fluid, with special reference to glucose in hyperglycemic conditions. Albrecht Von Graefes Arch Klin Exp Ophthalmol 202(1):1-7
-
(1977)
Albrecht von Graefes Arch Klin Exp Ophthalmol
, vol.202
, Issue.1
, pp. 1-7
-
-
Van Haeringen, N.J.1
Glasius, E.2
-
13
-
-
53049091680
-
Oxidative stress in diseases of the human cornea
-
10.1016/j.freeradbiomed.2008.07.021 1:CAS:528:DC%2BD1cXht1SiurzE
-
Shoham A, Hadziahmetovic M, Dunaief JL, Mydlarski MB, Schipper HM (2008) Oxidative stress in diseases of the human cornea. Free Radic Biol Med 45(8):1047-1055
-
(2008)
Free Radic Biol Med
, vol.45
, Issue.8
, pp. 1047-1055
-
-
Shoham, A.1
Hadziahmetovic, M.2
Dunaief, J.L.3
Mydlarski, M.B.4
Schipper, H.M.5
-
14
-
-
0026321812
-
Antioxidant enzymes in human tears
-
1:CAS:528:DyaK38Xht1Ggtbk%3D
-
Crouch RK, Goletz P, Snyder A, Coles WH (1991) Antioxidant enzymes in human tears. J Ocul Pharmacol 7(3):253-258
-
(1991)
J Ocul Pharmacol
, vol.7
, Issue.3
, pp. 253-258
-
-
Crouch, R.K.1
Goletz, P.2
Snyder, A.3
Coles, W.H.4
-
15
-
-
0031885395
-
Tear fluid content of electrochemically active components including water soluble antioxidants
-
10.1076/ceyr.17.3.257.5213 1:STN:280:DyaK1c3gsFaitA%3D%3D
-
Gogia R, Richer SP, Rose RC (1998) Tear fluid content of electrochemically active components including water soluble antioxidants. Curr Eye Res 17(3):257-263
-
(1998)
Curr Eye Res
, vol.17
, Issue.3
, pp. 257-263
-
-
Gogia, R.1
Richer, S.P.2
Rose, R.C.3
-
16
-
-
0022546030
-
Ascorbic-acid levels in the aqueous-humor of nocturnal and diurnal mammals
-
10.1001/archopht.1986.01050170143039 1:CAS:528:DyaL28XksFygtr0%3D
-
Reiss GR, Werness PG, Zollman PE, Brubaker RF (1986) Ascorbic-acid levels in the aqueous-humor of nocturnal and diurnal mammals. AMA Arch Ophthalmol 104(5):753-755
-
(1986)
AMA Arch Ophthalmol
, vol.104
, Issue.5
, pp. 753-755
-
-
Reiss, G.R.1
Werness, P.G.2
Zollman, P.E.3
Brubaker, R.F.4
-
17
-
-
0025260734
-
Lipid soluble antioxidants preserve rabbit corneal cell-function
-
10.3109/02713689008995196 1:STN:280:DyaK3c3kt1KrtQ%3D%3D
-
Luxneuwirth O, Millar TJ (1990) Lipid soluble antioxidants preserve rabbit corneal cell-function. Curr Eye Res 9(2):103-109
-
(1990)
Curr Eye Res
, vol.9
, Issue.2
, pp. 103-109
-
-
Luxneuwirth, O.1
Millar, T.J.2
-
18
-
-
0019426669
-
Clinical biochemistry of tears
-
10.1016/0039-6257(81)90145-4 1:CAS:528:DyaL3MXlvF2rurc%3D
-
Vanhaeringen NJ (1981) Clinical biochemistry of tears. Surv Ophthalmol 26(2):84-96
-
(1981)
Surv Ophthalmol
, vol.26
, Issue.2
, pp. 84-96
-
-
Vanhaeringen, N.J.1
-
19
-
-
0027268660
-
Dopamine and its metabolites in human tears
-
1:STN:280:DyaK3szlslKmtQ%3D%3D
-
Martin X, Brennan M (1993) Dopamine and its metabolites in human tears. Eur J Ophthalmol 3(2):83-88
-
(1993)
Eur J Ophthalmol
, vol.3
, Issue.2
, pp. 83-88
-
-
Martin, X.1
Brennan, M.2
-
20
-
-
0014265262
-
Tear glucose detection of hyperglycemia
-
1:STN:280:DyaF1c7ptVOlsA%3D%3D
-
Gasset AR, Braverma L, Fleming MC, Arky RA, Alter BR (1968) Tear glucose detection of hyperglycemia. Am J Ophthalmol 65(3):414-420
-
(1968)
Am J Ophthalmol
, vol.65
, Issue.3
, pp. 414-420
-
-
Gasset, A.R.1
Braverma, L.2
Fleming, M.C.3
Arky, R.A.4
Alter, B.R.5
-
21
-
-
0030224933
-
Analysis of tear fluid by CE/LIF: A noninvasive approach for glucose monitoring
-
1:CAS:528:DyaK2sXkt1elsrw%3D
-
Chen R, Jin Z, Colon LA (1996) Analysis of tear fluid by CE/LIF: a noninvasive approach for glucose monitoring. J Capillary Electrophor 3(5):243-248
-
(1996)
J Capillary Electrophor
, vol.3
, Issue.5
, pp. 243-248
-
-
Chen, R.1
Jin, Z.2
Colon, L.A.3
-
22
-
-
33846431237
-
Analysis of tear glucose concentration with electrospray ionization mass spectrometry
-
10.1016/j.jasms.2006.10.002 1:CAS:528:DC%2BD2sXht1WgsL0%3D
-
Taormina CR, Baca JT, Asher SA, Grabowski JJ, Finegold DN (2007) Analysis of tear glucose concentration with electrospray ionization mass spectrometry. J Am Soc Mass Spectrom 18(2):332-336
-
(2007)
J Am Soc Mass Spectrom
, vol.18
, Issue.2
, pp. 332-336
-
-
Taormina, C.R.1
Baca, J.T.2
Asher, S.A.3
Grabowski, J.J.4
Finegold, D.N.5
-
23
-
-
34347368491
-
Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers
-
10.1373/clinchem.2006.078543 1:CAS:528:DC%2BD2sXntlCqt7w%3D
-
Baca JT, Taormina CR, Feingold E, Finegold DN, Grabowski JJ, Asher SA (2007) Mass spectral determination of fasting tear glucose concentrations in nondiabetic volunteers. Clin Chem 53(7):1370-1372
-
(2007)
Clin Chem
, vol.53
, Issue.7
, pp. 1370-1372
-
-
Baca, J.T.1
Taormina, C.R.2
Feingold, E.3
Finegold, D.N.4
Grabowski, J.J.5
Asher, S.A.6
-
24
-
-
9244233374
-
Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid
-
10.1373/clinchem.2004.039701 1:CAS:528:DC%2BD2cXhtVersrfM
-
Alexeev VL, Das S, Finegold DN, Asher SA (2004) Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid. Clin Chem 50(12):2353-2360
-
(2004)
Clin Chem
, vol.50
, Issue.12
, pp. 2353-2360
-
-
Alexeev, V.L.1
Das, S.2
Finegold, D.N.3
Asher, S.A.4
-
25
-
-
10644265364
-
Fluorescence sensors for monosaccharides based on the 6-methylquinolinium nucleus and boronic acid moiety: Potential application to ophthalmic diagnostics
-
10.1016/j.talanta.2004.08.003 1:CAS:528:DC%2BD2cXhtFamsrfF
-
Badugu R, Lakowicz JR, Geddes CD (2005) Fluorescence sensors for monosaccharides based on the 6-methylquinolinium nucleus and boronic acid moiety: potential application to ophthalmic diagnostics. Talanta 65(3):762-768
-
(2005)
Talanta
, vol.65
, Issue.3
, pp. 762-768
-
-
Badugu, R.1
Lakowicz, J.R.2
Geddes, C.D.3
-
26
-
-
78650172137
-
Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment
-
10.1016/j.talanta.2010.10.055 1:CAS:528:DC%2BC3cXhsFCrur3J
-
Chu MX, Miyajima K, Takahashi D, Arakawa T, Sano K, Sawada S, Kudo H, Iwasaki Y, Akiyoshi K, Mochizuki M, Mitsubayashi K (2011) Soft contact lens biosensor for in situ monitoring of tear glucose as non-invasive blood sugar assessment. Talanta 83(3):960-965
-
(2011)
Talanta
, vol.83
, Issue.3
, pp. 960-965
-
-
Chu, M.X.1
Miyajima, K.2
Takahashi, D.3
Arakawa, T.4
Sano, K.5
Sawada, S.6
Kudo, H.7
Iwasaki, Y.8
Akiyoshi, K.9
Mochizuki, M.10
Mitsubayashi, K.11
-
27
-
-
78649690667
-
3-D nanoporous gold thin film for the simultaneous electrochemical determination of dopamine and ascorbic acid
-
10.1016/j.elecom.2010.10.015 1:CAS:528:DC%2BC3cXhsFaqtr3E
-
El-Said WA, Lee JH, Oh BK, Choi JW (2010) 3-D nanoporous gold thin film for the simultaneous electrochemical determination of dopamine and ascorbic acid. Electrochem Commun 12(12):1756-1759
-
(2010)
Electrochem Commun
, vol.12
, Issue.12
, pp. 1756-1759
-
-
El-Said, W.A.1
Lee, J.H.2
Oh, B.K.3
Choi, J.W.4
-
28
-
-
0242694059
-
On-line microfluidic sensor integrated with a micro array electrode and enzyme-modified pre-reactor for the real-time monitoring of blood catecholamine
-
10.1016/j.elecom.2003.10.005 1:CAS:528:DC%2BD3sXos1antLo%3D
-
Hayashi K, Iwasaki Y, Kurita R, Sunagawa K, Niwa O (2003) On-line microfluidic sensor integrated with a micro array electrode and enzyme-modified pre-reactor for the real-time monitoring of blood catecholamine. Electrochem Commun 5(12):1037-1042
-
(2003)
Electrochem Commun
, vol.5
, Issue.12
, pp. 1037-1042
-
-
Hayashi, K.1
Iwasaki, Y.2
Kurita, R.3
Sunagawa, K.4
Niwa, O.5
-
29
-
-
70349446315
-
Electropolymerized film of functionalized thiadiazole on glassy carbon electrode for the simultaneous determination of ascorbic acid, dopamine and uric acid
-
10.1016/j.bioelechem.2009.04.010 1:CAS:528:DC%2BD1MXht1WmsrjP
-
Kalimuthu P, John SA (2009) Electropolymerized film of functionalized thiadiazole on glassy carbon electrode for the simultaneous determination of ascorbic acid, dopamine and uric acid. Bioelectrochemistry 77(1):13-18
-
(2009)
Bioelectrochemistry
, vol.77
, Issue.1
, pp. 13-18
-
-
Kalimuthu, P.1
John, S.A.2
-
30
-
-
12744271529
-
Electrochemical biosensor based on protein-polysaccharide hybrid for selective detection of nanomolar dopamine metabolite of 3,4- dihydroxyphenylacetic acid (DOPAC)
-
10.1016/j.elecom.2004.12.015 1:CAS:528:DC%2BD2MXmvF2rtg%3D%3D
-
Liu AH, Honma I, Zhou HS (2005) Electrochemical biosensor based on protein-polysaccharide hybrid for selective detection of nanomolar dopamine metabolite of 3,4-dihydroxyphenylacetic acid (DOPAC). Electrochem Commun 7(2):233-236
-
(2005)
Electrochem Commun
, vol.7
, Issue.2
, pp. 233-236
-
-
Liu, A.H.1
Honma, I.2
Zhou, H.S.3
-
31
-
-
52149113076
-
Simultaneous determination of dopamine, ascorbic acid and uric acid with electrospun carbon nanofibers modified electrode
-
10.1016/j.elecom.2008.07.020 1:CAS:528:DC%2BD1cXhtFOgtLfN
-
Liu Y, Huang JS, Hou HQ, You TY (2008) Simultaneous determination of dopamine, ascorbic acid and uric acid with electrospun carbon nanofibers modified electrode. Electrochem Commun 10(10):1431-1434
-
(2008)
Electrochem Commun
, vol.10
, Issue.10
, pp. 1431-1434
-
-
Liu, Y.1
Huang, J.S.2
Hou, H.Q.3
You, T.Y.4
-
32
-
-
77949293234
-
Simultaneous determination of ascorbic acid, dopamine and uric acid using polystyrene sulfonate wrapped multiwalled carbon nanotubes bound to graphite electrode through layer-by-layer technique
-
10.1016/j.snb.2010.01.011
-
Manjunatha R, Suresh GS, Melo JS, D'Souza SF, Venkatesha TV (2010) Simultaneous determination of ascorbic acid, dopamine and uric acid using polystyrene sulfonate wrapped multiwalled carbon nanotubes bound to graphite electrode through layer-by-layer technique. Sensors Actuators B Chem 145(2):643-650
-
(2010)
Sensors Actuators B Chem
, vol.145
, Issue.2
, pp. 643-650
-
-
Manjunatha, R.1
Suresh, G.S.2
Melo, J.S.3
D'Souza, S.F.4
Venkatesha, T.V.5
-
33
-
-
0037468560
-
Gold nanoparticle arrays for the voltammetric sensing of dopamine
-
10.1016/S0022-0728(02)01481-X 1:CAS:528:DC%2BD3sXhtlKjsL8%3D
-
Raj CR, Okajima T, Ohsaka T (2003) Gold nanoparticle arrays for the voltammetric sensing of dopamine. J Electroanal Chem 543(2):127-133
-
(2003)
J Electroanal Chem
, vol.543
, Issue.2
, pp. 127-133
-
-
Raj, C.R.1
Okajima, T.2
Ohsaka, T.3
-
34
-
-
38049000740
-
Conductive organic complex salt TTF-TCNQ as a mediator for biosensors. An overview
-
10.1002/elan.200704035 1:CAS:528:DC%2BD1cXltlentrc%3D
-
Pauliukaite R, Malinauskas A, Zhylyak G, Spichiger-Keller UE (2007) Conductive organic complex salt TTF-TCNQ as a mediator for biosensors. An overview. Electroanalysis 19(24):2491-2498
-
(2007)
Electroanalysis
, vol.19
, Issue.24
, pp. 2491-2498
-
-
Pauliukaite, R.1
Malinauskas, A.2
Zhylyak, G.3
Spichiger-Keller, U.E.4
-
35
-
-
0025475560
-
Electrochemical and quartz crystal microbalance evidence for mediation and direct electrochemical reactions of small molecules at tetrathiafulvalene- tetracyanoquinodimethane (TTF-TCNQ) electrodes
-
1:CAS:528:DyaK3cXmtVSjsrc%3D
-
Freund MS, Brajtertoth A, Ward MD (1990) Electrochemical and quartz crystal microbalance evidence for mediation and direct electrochemical reactions of small molecules at tetrathiafulvalene-tetracyanoquinodimethane (TTF-TCNQ) electrodes. J Electroanal Chem 289(1-2):127-141
-
(1990)
J Electroanal Chem
, vol.289
, Issue.1-2
, pp. 127-141
-
-
Freund, M.S.1
Brajtertoth, A.2
Ward, M.D.3
-
36
-
-
0030258019
-
Construction of SEC/CTC electrodes for direct electron transferring biosensors
-
10.1016/S0925-4005(97)80117-7
-
Khan GF (1996) Construction of SEC/CTC electrodes for direct electron transferring biosensors. Sensors Actuators B Chem 36(1-3):484-490
-
(1996)
Sensors Actuators B Chem
, vol.36
, Issue.1-3
, pp. 484-490
-
-
Khan, G.F.1
-
37
-
-
0023324505
-
Tetrathiafulvalene tetracyanoquinodimethane xanthine-oxidase amperometric electrode for the determination of biological purines
-
10.1021/ac00134a006 1:CAS:528:DyaL2sXpvVOiuw%3D%3D
-
McKenna K, Brajtertoth A (1987) Tetrathiafulvalene tetracyanoquinodimethane xanthine-oxidase amperometric electrode for the determination of biological purines. Anal Chem 59(7):954-958
-
(1987)
Anal Chem
, vol.59
, Issue.7
, pp. 954-958
-
-
McKenna, K.1
Brajtertoth, A.2
-
38
-
-
33947584425
-
Development of a carbon nanotube paste electrode osmium polymer-mediated biosensor for determination of glucose in alcoholic beverages
-
10.1016/j.bios.2006.10.023 1:CAS:528:DC%2BD2sXjslGmtLw%3D
-
Antiochia R, Gorton L (2007) Development of a carbon nanotube paste electrode osmium polymer-mediated biosensor for determination of glucose in alcoholic beverages. Biosens Bioelectron 22(11):2611-2617
-
(2007)
Biosens Bioelectron
, vol.22
, Issue.11
, pp. 2611-2617
-
-
Antiochia, R.1
Gorton, L.2
-
39
-
-
80155149877
-
Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
-
10.1021/ac201700c 1:CAS:528:DC%2BC3MXhtlSltL7N
-
Yan QY, Peng B, Su G, Cohan BE, Major TC, Meyerhoff ME (2011) Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration. Anal Chem 83(21):8341-8346
-
(2011)
Anal Chem
, vol.83
, Issue.21
, pp. 8341-8346
-
-
Yan, Q.Y.1
Peng, B.2
Su, G.3
Cohan, B.E.4
Major, T.C.5
Meyerhoff, M.E.6
-
40
-
-
79956085066
-
Construction of an amperometric ascorbate biosensor using epoxy resin membrane bound Lagenaria siceraria fruit ascorbate oxidase
-
10.3109/10731199.2010.525711 1:CAS:528:DC%2BC3MXmtFahu7w%3D
-
Pundir CS, Chauhan N, Jyoti (2011) Construction of an amperometric ascorbate biosensor using epoxy resin membrane bound Lagenaria siceraria fruit ascorbate oxidase. Artif Cells Blood Substit 39(3):177-184
-
(2011)
Artif Cells Blood Substit
, vol.39
, Issue.3
, pp. 177-184
-
-
Pundir, C.S.1
Chauhan, N.2
Jyoti3
-
41
-
-
0023152698
-
Vitamin-C levels in human tears
-
10.1001/archopht.1987.01060030096034 1:CAS:528:DyaL2sXitFWntrw%3D
-
Paterson CA, Orourke MC (1987) Vitamin-C levels in human tears. AMA Arch Ophthalmol 105(3):376-377
-
(1987)
AMA Arch Ophthalmol
, vol.105
, Issue.3
, pp. 376-377
-
-
Paterson, C.A.1
Orourke, M.C.2
|